:: UI - Skripsi Membership :: Kembali

UI - Skripsi Membership :: Kembali

Analisis cemaran bisfenol A pada sampel minuman kaleng dengan kromatografi gas menggunakan detektor ionisasi nyala = Analysis of bisphenol A in canned beverages by gas chromatogaphy using flame ionization detector

Faatichatun Naja; Herman Suryadi, supervisor; Harahap, Yahdiana, supervisor; Maggadani, Baitha Palanggatan, examiner; Hayun, examiner ([Publisher not identified] , 2017)

 Abstrak

ABSTRAK
Bisfenol A BPA merupakan senyawa kimia yang digunakan pada produksi polimer plastik polikarbonat dan epoksi resin yang banyak digunakan pada wadah minuman kaleng. BPA telah menjadi sorotan publik karena merupakan senyawa pengganggu endokrin EDC dan memiliki potensi yang dapat mengganggu sistem hormon manusia. Penelitian ini bertujuan untuk mendapatkan metode yang sensitif, selektif, dan valid untuk analisis BPA dalam sampel minuman kaleng menggunakan Kromatografi Gas-Detektor Ionisasi Nyala. Kolom yang digunakan yaitu kolom kapiler HP-1 dengan panjang kolom 30m, diameter dalam 0,25 mm, dan tebal film 0,25 m. Gas pembawa yang digunakan yaitu gas nitrogen dengan laju alir 1 mL/menit. Penyiapan sampel menggunakan metode ekstraksi cair-cair dengan etil asetat sebagai pelarut pengesktraksi. Hasil validasi linearitas yaitu 0,9998, nilai batas deteksi LOD 0,287 g/mL, dan batas kuantitasi LOQ 0,956 g/mL. Validasi yang mencakup liniearitas, selektivitas, akurasi, presisi, LOD , dan LOQ, telah memenuhi syarat keberterimaan. Hasil analisis cemaran menunjukkan bahwa satu dari tiga merek yang dianalisis positif mengandung BPA dengan kadar 2,4090 g/mL.

ABSTRACT
Bisphenol A BPA is a chemical compound use in the production of polycarbonate plastic polymers and epoxy resins which are widely use for canned beverage containers. People are concerned with BPA because BPA is an endocrine disruptive compound EDC and has the potential to disrupt the human hormone system. The purpose of this study is to achieve sensitive, selective, and valid methods for BPA analysis in beverage samples using Gas Chromatography Flame Ionization Detector. The column used was HP 1 capillary columns with a column length of 30m, an inner diameter of 0.25 mm, and a film thickness of 0.25 m. The carrier gas used was nitrogen with a flow rate of 1 mL min. Preparation of the samples using liquid liquid extraction method with ethyl acetate as an extracting solvent. The value of linearity is 0.9998, with limit of detection LOD 0.287 g mL and limit of quantitation LOQ 0.956 g mL. Validation including liniearity, selectivity, accuracy, precision, limit of detection, and limit of quantitation have met the acceptable conditions. The results of contamination analysis showed that one of the three brands analyzed positively contained BPA with levels of 2.4090 g mL.

 File Digital: 1

Shelf
 S67395-Faatichatun Naja.pdf :: Unduh

LOGIN required

 Metadata

No. Panggil : S67395
Entri utama-Nama orang :
Entri tambahan-Nama orang :
Entri tambahan-Nama badan :
Subjek :
Penerbitan : [Place of publication not identified]: [Publisher not identified], 2017
Program Studi :
Bahasa : ind
Sumber Pengatalogan : LibUI ind rda
Tipe Konten : text
Tipe Media : unmediated ; computer
Tipe Carrier : volume ; online resource
Deskripsi Fisik : xvii, 52 pages : illustration ; 30 cm + appendix
Naskah Ringkas :
Lembaga Pemilik : Universitas Indonesia
Lokasi : Perpustakaan UI, Lantai 3
  • Ketersediaan
  • Ulasan
No. Panggil No. Barkod Ketersediaan
S67395 14-19-643441234 TERSEDIA
Ulasan:
Tidak ada ulasan pada koleksi ini: 20458486