Pengaruh Distorsi Radiograf Sefalometri Lateral Akibat Kemiringan Kepala pada Sumbu Anteroposterior terhadap Distorsi Pengukuran Angular Sefalometri = Effect of Distortion of Lateral Cephalometric Radiographs Due to Head Tilting on Anteroposterior Axis Against Distortion of Cephalometric Angular Measurement
Handita Permata Sari;
Syurri Innaddinna Syahraini, supervisor; Menik Priaminiarti, supervisor; Hanna Bachtiar, examiner; Heru Suryonegoro, examiner
(Fakultas Kedokteran Gigi Universitas Indonesia, 2017)
|
Latar Belakang: Kesalahan posisi kepala dalam sefalostat saat pembuatan radiografis sefalometri lateral mengakibatkan distorsi pada radiograf yang dihasilkan. Hal ini mempengaruhi pada diagnosis dan rencana perawatan orthodonti pasien. Tujuan: Mengetahui pengaruh distorsi radiografis sefalometri lateral akibat kemiringan kepala pada sumbu anteroposterior terhadap distorsi pengukuran angular sefalometri lateral. Metode: Radiografis sefalometri lateral terhadap 7 kranium dengan sudut sebesar 0 , -20 , -15 , -10 , -5 , 5 , 10 , 15 , dan 20 terhadap sumbu anteroposterior. Radiograf dilakukan analisis sefalometri oleh dua orang pengamat. Uji reliabilitas dilakukan dengan uji Bland Altman. Uji kemaknaan dilakukan dengan uji T Berpasangan dan uji Wilcoxon. Hasil: Terdapat perbedaan bermakna antara pengukuran 8 parameter sudut dengan kemiringan kepala lebih dari 10 p. Background: Head position errors in the cephalostate during the lateral cephalometric projection result in radiographic distortion. This may affect the diagnosis and treatment plan of orthodontic patient's. Objective: To discover the effect of lateral cephalometric radiograph distortion due to head tilting on the anteroposterior axis against distortion of lateral cephalometric angular measurements. Methods: Lateral cephalometric radiograph of 7 human dry skulls with tilting angle of 0 , 20 , 15 , 10 , 5 , 5 , 10 , 15 , and 20 to the anteroposterior axis. Radiographs were analyzed by two observers. Reliability test is done by Bland Altman test. The significance test is done by paired T test and Wilcoxon test. Results: There was a significant difference between the measurement of 8 angle parameters with head tilting greater than 10 p |
S-Handita Permata Sari.pdf :: Unduh
|
No. Panggil : | S-Pdf |
Entri utama-Nama orang : | |
Entri tambahan-Nama orang : | |
Subjek : | |
Penerbitan : | Jakarta: Fakultas Kedokteran Gigi Universitas Indonesia, 2017 |
Program Studi : |
Bahasa : | ind |
Sumber Pengatalogan : | LibUI ind rda |
Tipe Konten : | text |
Tipe Media : | computer |
Tipe Carrier : | online resource |
Deskripsi Fisik : | xv, 50 pages : illustration ; 28 cm + appendix |
Naskah Ringkas : | |
Lembaga Pemilik : | Universitas Indonesia |
Lokasi : | Perpustakaan UI, Lantai 3 |
No. Panggil | No. Barkod | Ketersediaan |
---|---|---|
S-Pdf | 14-18-487719480 | TERSEDIA |
Ulasan: |
Tidak ada ulasan pada koleksi ini: 20466606 |