:: UI - Skripsi Membership :: Kembali

UI - Skripsi Membership :: Kembali

Evaluasi rancangan sepatu pada penggunaan media miring ketika berdiri berkepanjangan terhadap risiko lower extremity pain dan low back pain = Shoes design evaluation on sloping media usage when prolonged standing into lower risk extremity pain and low back pain

Ghassani Shabrina; Billy Muhamad Iqbal, supervisor; Erlinda Muslim, examiner; Boy Nurtjahyo Moch., examiner; Zulkarnain, examiner; Danu Hadi Syaifullah, examiner (Fakultas Teknik Universitas Indonesia, 2018)

 Abstrak

Media dengan kemiringan 16o merupakan solusi efektif untuk mereduksi risiko low back pain akibat berdiri berkepanjangan. Sepatu yang berpengaruh terhadap besaran low back pain pada saat berdiri berkepanjangan, pada penelitian ini diteliti pengaruhnya terhadap besaran low back pain pada kondisi berdiri selama 2 jam diatas media miring. Namun berdiri berkepanjangan memiliki faktor risiko besar lainnya yaitu lower extremity pain, dimana dalam banyak penelitian risiko tersebut dapat dipengaruhi oleh faktor sepatu sehingga lower extremity pain menjadi parameter utama yang diteliti pada penelitian ini. Sepatu yang diteliti adalah sepatu Safety dan Slip On dimana keduanya merupakan jenis sepatu yang paling banyak digunakan di industri manufaktur. Menggunakan metode Surface Electromyography SEMG, perbedaan respon otot Medial Gastrocnemius diukur terhadap kedua jenis sepatu yang pada penelitian ini ditemukan bahwa kedua jenis sepatu memiliki besaran aktivitas otot yang berbeda dan sepatu Safety memperlihatkan aktivitas yang lebih besar. Hal ini membuktikan bahwa sepatu berpengaruh terhadap besaran lower extremity pain saat berdiri selama 2 jam diatas media miring, serta sepatu Safety memiliki risiko lower extremity pain yang lebih besar. Metode Visual Analog Scale VAS dan Foot Pain Questionnaire mendukung temuan tersebut dengan memberikan hasil yan serupa. Pada penelitian ini ditemukan pula bahwa aktivitas berdiri selama 2 jam diatas media miring memiliki risiko lower extremity pain yang lebih besar dibandingkan dengan risiko low back pain berdasarkan pada nilai VAS. Pada metode Foot Pain Questionnaire ditemukan bahwa media miring meningkatkan risiko nyeri pada bagian ibu jari kaki dan telapak kaki bagian belakang. Maka penelitian ini merekomendasikan bahwa perlunya rancangan sepatu khusus untuk berdiri berkepanjangan pada media miring yang dapat mereduksi risiko lower extremity pain disamping risiko low back pain.

Media with 16o slope is an effective solution to reduce the risk of low back pain due to prolonged standing. Shoes that affect the amount of low back pain on prolonged standing, in this study examined the effect on the amount of low back pain on standing condition for 2 hours on sloping medium. However, prolonged standing has another major risk factor that is lower extremity pain, where in many studies the risk can be affected by shoes factor so that lower extremity pain becomes the main parameter studied in this research. The shoes observed in this study are Safety Shoes and Slip On as the most widely used shoes in the manufacturing industry. Using the Surface Electromyography SEMG method, the difference in Medial Gastrocnemius muscle response was measured against both types of shoes which in this study resulted that both types of shoes have different muscle activation values and Safety Shoes show greater activation. This proves that the shoe effect on the amount of lower extremity pain while standing for 2 hours on sloping medium and Safety Shoes have lower extremity risk. Visual Analog Scale VAS and Foot Pain Questionnaire methods support that right by giving the same results. This study also found that the activity of standing for 2 hours on sloping media has lower extremity pain risk greater than the risk of low back pain from the results of VAS method. Foot Pain Questionnaire method indicates that the activity of standing for 2 hours over sloping media has a high risk in thumb and the back foot. So in this study the authors recommend that it is necessary to design a special shoe for prolonged standing on a sloping medium that reduces the reduction of lower extremity pain risk besides low back pain risk.

 File Digital: 1

Shelf
 S-Pdf-Ghassani Shabrina.pdf :: Unduh

LOGIN required

 Metadata

No. Panggil : S-Pdf
Entri utama-Nama orang :
Entri tambahan-Nama orang :
Subjek :
Penerbitan : Depok: Fakultas Teknik Universitas Indonesia, 2018
Program Studi :
Bahasa : ind
Sumber Pengatalogan : LibUI ind rda
Tipe Konten : text
Tipe Media : computer
Tipe Carrier : online resource
Deskripsi Fisik : xiii, 95 pages : illustration ; appendix
Naskah Ringkas :
Lembaga Pemilik : Universitas Indonesia
Lokasi : Perpustakaan UI, Lantai 3
  • Ketersediaan
  • Ulasan
No. Panggil No. Barkod Ketersediaan
S-Pdf 14-20-380330897 TERSEDIA
Ulasan:
Tidak ada ulasan pada koleksi ini: 20472615