Pengaruh penggunaan nesting dengan fiksasi dan posisi terhadap fungsi fisiologis dan status tidur terjaga pada bayi dengan berat lahir rendah = Effect of applying nesting with fixation and positioning on physiological function and sleep-awake status on low birth weight infant
Reisy Tane;
Yeni Rustina, supervisor; Fajar Tri Waluyanti, supervisor; Defi Efendi, examiner; Yanti Riyantini, examiner
(Fakultas Ilmu Keperawatan Universitas Indonesia, 2018)
|
Bayi berat lahir rendah yang dirawat di ruang Perinatologi memiliki masalah utama terganggunya status tidur terjaga diikuti oleh ketidakstabilan fungsi fisiologis saturasi oksigen dan frekuensi nadi. Penelitian ini bertujuan untuk melihat pengaruh penggunaan nesting dengan fiksasi terhadap fungsi fisiologis dan status tidur tejaga pada bayi berat lahir rendah. Penelitian ini menggunakan rancangan uji klinik acak terkontrol tipe cross over. Sampel penelitian ini berjumlah 19 bayi dengan berat lahir rendah yang dirawat di ruang Perinatologi RSUP Fatmawati Jakarta. Hasil penelitian ini menunjukkan bahwa terdapat perbedaan bermakna penggunaan nesting dengan fiksasi terhadap rerata saturasi oksigen dengan posisi prone dan quarterprone p0,05 . Pemberian nesting dengan fiksasi dengan posisi prone status tidur tenang mendominasi sebesar 96,8 p=0,0001 diikuti dengan posisi quarterprone 95,7 p=0,0001 . Penggunaan nesting dengan fiksasi dapat memfasilitasi tidur tenang dan kestabilan fungsi fisiologis pada BBLR. Rekomendasi dari penelitian selanjutnya adalah perbandingan nesting fiksasi dengan nesting yang terbuat dari bahan tradisional terhadap status tidur terjaga. Low birth weight infant who treated in the Perinatology has a major problem of sleep awake status disturbance followed by instability on the physiological function of oxygen saturation and pulse frequency. This study aims to investigate the effect of applying nest with a fixation on physiological function and sleep awake status on low birth weight infant. This study uses a randomized controlled trial with cross over design. The sample of this study was 19 low birth weight infant in Perinatology Fatmawati Hospital. The result of this studies indicates that there is a significant relationship between applying of nesting with fixation on oxygen saturation rate with prone and quarterprone position p 0,05. At the time of nesting fixation with prone position, the majority of sleep awake status is quiet sleep 96.8 p 0.0001 followed by the quarterprone position of 95.7 p 0.0001. The use of nesting with fixation may facilitate quiet sleep and the stability of physiological functions in LBW. The recommendation for further research is comparing a nesting fixation with another type of nesting with a fixation on sleep awake status. |
T50574-Reisy Tane.pdf :: Unduh
|
No. Panggil : | T50574 |
Entri utama-Nama orang : | |
Entri tambahan-Nama orang : | |
Entri tambahan-Nama badan : | |
Subjek : | |
Penerbitan : | Depok: Fakultas Ilmu Keperawatan Universitas Indonesia, 2018 |
Program Studi : |
Bahasa : | ind |
Sumber Pengatalogan : | LibUI ind rda |
Tipe Konten : | text |
Tipe Media : | unmediated ; computer |
Tipe Carrier : | volume ; online resource |
Deskripsi Fisik : | xv, 132 pages : illustration ; 28 cm + appendix |
Naskah Ringkas : | |
Lembaga Pemilik : | Universitas Indonesia |
Lokasi : | Perpustakaan UI, Lantai 3 |
No. Panggil | No. Barkod | Ketersediaan |
---|---|---|
T50574 | 15-20-917750510 | TERSEDIA |
Ulasan: |
Tidak ada ulasan pada koleksi ini: 20476103 |