Studi eksperimental silica gel-water adsorption chiller menggunakan adsorber dengan dua jenis FIN = Experimental study of silica gel-water adsorption chiller using adsorber with two types of FIN / Andre Kurniawan

Andre Kurniawan; Nasruddin, supervisor; Engkos Achmad Kosasih, examiner; Muhammad Idrus Alhamid, examiner; Agus Sunjarianto Pamitran, examiner; Ridho Irwansyah, examiner ([Publisher not identified] , 2018)

 Abstrak

ABSTRAK
Teknologi adsorpsi menjadi salah satu solusi oleh peneliti saat ini untuk menyelesaikan permasalahan energi dan lingkungan. Bagian utama sistem pendingin adsorpsi adalah adsorben dan adsorbat. Salah satu adsorben yang paling banyak digunakan dalam penelitian tentang pendinginan adsorpsi adalah silika gel. Konfigurasi chiller terdiri atas dua ruang penyerapan dengan menggunakan fin tube heat exchangers sebagai adsorber, kondenser, and evaporator. Chiller diuji pada kondisi temperatur hot water inlet/cooling water inlet/chilled water inlet/outlet sebesar 79.2/29.4/11.0/8.5oC. Heat dan mass recovery diadopsi dalam eksperimen untuk meningkatkan kapasitas pendinginan. Waktu proses pendinginan divariasikan untuk memperoleh waktu optimal berkaitan dengan performa. Nilai terbaik untuk COP dan kapasitas pendinginan diperoleh sebesar 0.52 dan 3.1 kW menggunakan jarak fin 3 mm pada saat waktu adsorpsi/desorpsi sebesar 700 s.

ABSTRACT
The adsorption technology is becoming the more expected solution by today 39 s researchers for fix the energy and environmental issues. The main part of the cooling system adsorption is adsorbent and adsorbate. One of the most widely used adsorbents in research of adsorption technology is silica gel. A new silica gel water adsorption chiller design was developed that composed of two sorption chambers with compact fin tube heat exchangers as adsorber, condenser, and evaporator. The chiller is tested under typical condition for hot water inlet cooling water inlet chilled water inlet outlet temperatures are 79.2 29.4 11.0 8.5oC, respectively. Heat and mass recovery were adopted in experiment to increase the cooling capacity. The cooling time was variated to obtain the heat recovery optimum time related to the performance. Best value of COP and cooling power were obtained 0.52 and 3.1 kW using 3 mm range of fin, respectively, at adsorption desorption time 700 s.

 File Digital: 1

Shelf
 T50886-Andre Kurniawan.pdf :: Unduh

LOGIN required

 Metadata

No. Panggil : T50886
Entri utama-Nama orang :
Entri tambahan-Nama orang :
Entri tambahan-Nama badan :
Subjek :
Penerbitan : [Place of publication not identified]: [Publisher not identified], 2018
Program Studi :
Bahasa : ind
Sumber Pengatalogan : LibUI ind rda
Tipe Konten : text
Tipe Media : unmediated ; computer
Tipe Carrier : volume ; online resource
Deskripsi Fisik : xvi, 68 pages : illustration ; 28 cm + appendix
Naskah Ringkas :
Lembaga Pemilik : Universitas Indonesia
Lokasi : Perpustakaan UI, Lantai 3
  • Ketersediaan
  • Ulasan
No. Panggil No. Barkod Ketersediaan
T50886 15-20-660037797 TERSEDIA
Ulasan:
Tidak ada ulasan pada koleksi ini: 20476299