Analisis parameter dosimetri antara teknik intensity modulated radiotherapy (IMRT), volumetric modulated arc therapy (VMAT), dan helical tomotherapy (HT) pada hippocampal sparing whole brain radiotherapy (HS-WBRT) = Dosimetric analysis of intensity modulated radiotherapy (IMRT), volumetric modulated arc therapy (VMAT) and helical tomotherapy (HT) in hippocampal sparing whole brain radiotherapy.

Hadi Nurhadi; Soehartati , supervisor; Arie Munandar, supervisor; Wahyu Edy Wibowo, supervisor; H.M. Djakaria, examiner; Nana Supriana, examiner; Irwan Ramli, examiner; Sri Mutya Sekarutami, examiner (Fakultas Kedokteran Universitas Indonesia, 2018)

 Abstrak

Latar Belakang: Radiasi eksterna seringkali digunakan untuk mengurangi gejala dari metastasis otak. Teknik radiasi paliatif Whole Brain masih merupakan terapi standar bagi pasien kanker dengan metastasis otak, namun teknik radiasi ini dapat menyebabkan penurunan fungsi neurokognitif yang diakibatkan oleh inflamasi akibat radiasi pada daerah hipokampus. Hal ini memicu penggunaan Hippocampal Sparing Whole Brain Radiotherapy (HS-WBRT) untuk mengurangi efek samping penurunan neurokogntif yang terkait hipokampus. Thesis ini membahas perbandingan dosimetri teknik radiasi Intensity Modulated Radiotherapy (IMRT), Volumetric Modulated Arc Therapy (VMAT), dan Helical Tomotherapy (HT) pada Hippocampal Sparing Whole Brain Radiotherapy (HS-WBRT) untuk menilai apakah ada perbedaan parameter dosimetri dari ketiga teknik radiasi tersebut. Penelitian ini merupakan studi eksperimental eksploratif dengan melakukan intervensi pada data CT-plan pasien metastasis otak secara in silico. Parameter dosimetri yang dinilai adalah Conformity Index, Homogenity Index, Treatment Time, D98% PTV, D2% PTV, D50% PTV, D100% Hipokampus, dan Dmax Hipokampus. Hasil penelitian ini menunjukkan adanya perbedaan yang signifikan secara statistik dalam parameter Homogenity Index, D98% PTV, D2% PTV, dan D50% PTV pada semua kelompok data teknik radiasi, dimana Helical Tomotherapy (HT) memiliki nilai rerata yang paling baik dibandingkan kedua teknik radiasi lainnya. Untuk parameter yang lainnya baik Intensity Modulated Radiotherapy (IMRT) maupun Volumetric Modulated Arc Therapy (VMAT) memiliki nilai rerata yang tidak berbeda bermakna, kedua teknik radiasi tersebut masih memungkinkan sebagai tehnik pilihan dalam HSWBRT. Masih diperlukan penelitian lebih lanjut dengan jumlah sampel yang lebih besar guna menilai dengan baik teknik radiasi mana yang paling unggul untuk digunakan dalam perencanaan HS-WBRT serta menghasilkan perencanaan radiasi yang lebih baik.

Background: Radiation therapy is still a standard treatment in brain metastases cases. Whole brain radiation therapy is widely used to reduce debilitating symptoms, on the other hand this treatment could decrease neurocognitif function due to radiationinduced inflammation of the hippocampus. This is the ground reason to apply Hippocampal Sparing Whole Brain Radiotherapy (HS-WBRT), in order to reduce hippocamus related side effects. The focus in this study is to analyze dosimetric parameter between Intensity Modulated Radiotherapy (IMRT), Volumetric Modulated Arc Therapy (VMAT), and Helical Tomotherapy (HT) in Hippocampal Sparing Whole Brain Radiotherapy (HS-WBRT) to asses any differences in dosimetric values. This study is an experimental study on CT and delivered treatment planing data, recalculated in silico as a hippocampal sparing treatment planning to be compared. The dosimetric parameter that were used in this study are Conformity Index, Homogenity Index, Treatment Time, D98% PTV, D2% PTV, D50% PTV, D100% Hippocampus, dan Dmax Hippocampus. The dosimetric comparisons between the three modalities resulted in statistically significant differences in Homogenity Index, D98% PTV, D2% PTV, D50% PTV, D100% where Helical Tomotherapy (HT) has a better mean value among the rest of the group. In other dosimetric comparisons, Intensity Modulated Radiotherapy (IMRT) and Volumetric Modulated Arc Therapy (VMAT) does not have any significant differences, as such both modalities allows for sparing of the hippocampus with acceptable means value in many dosimetric parameters. Further research is nedeed, particularly with larger sample to assess superiority in HS-WBRT modalities, as such to increase efficacy in its treatment planning.

 File Digital: 1

Shelf
 SP-PDF-Hadi_nurhadi.pdf :: Unduh

LOGIN required

 Metadata

No. Panggil : SP-pdf
Entri utama-Nama orang :
Entri tambahan-Nama orang :
Entri tambahan-Nama badan :
Subjek :
Penerbitan : Jakarta: Fakultas Kedokteran Universitas Indonesia, 2018
Program Studi :
Bahasa : Ind
Sumber Pengatalogan : LibUI ind rda
Tipe Konten : text
Tipe Media : computer
Tipe Carrier : online resource
Deskripsi Fisik : xiii, 52 pages : illustration + appendix.
Naskah Ringkas :
Lembaga Pemilik : Universitas Indonesia
Lokasi : Perpustakaan UI, Lantai 3