:: UI - Skripsi Membership :: Kembali

UI - Skripsi Membership :: Kembali

Pengaruh interaksi peralatan rumah tangga terhadap karakteristik disturbansi pada frekuensi 9 kHz-150 kHz = The impact of household appliances interaction respect to disturbance characteristics on frequency range 9 kHz-1590 kHz

Zainal Abidin; Budi Sudiarto, supervisor; I Made Ardita Y., examiner; Faiz Husnayain, examiner (Fakultas Teknik Universitas Indonesia, 2019)

 Abstrak

Penggunaan peralatan rumah tangga yang mengimplementasikan sistem inverter dapat meningkatkan efisiensi penggunaan energi listrik sekaligus memicu terbentuknya disturbansi. Disturbansi yang terbentuk dapat merambat secara konduktif yang dikenal sebagai conducted emission. Kararteristik disturbansi yang dihasilkan setiap peralatan rumah tangga bersifat unik. Disturbansi tersebut beradapada rentang frekuensi 9 kHz-150 kHz. Regulasi yang mengatur batas level tegangan disturbansi pada frekuensi tersebut masih terbatas. Peralatan rumah tangganyang dioperasikan simultan terhubung pararel pada jaringan listrik rumah tangga. Hal tersebut memicu terjadinya interaksi antar peralatan. Interaksi ersebut akan memicu pembentukan karakteristik disturbansi yang berbeda dengan karakteristik disturbansi yang dihasilkan oleh masing-masing peralatan.
Pada penelitian ini dilakukan pengukuran tegangan disturbansi yang dihasilkan peralatan rumah tangga pada rentang frekuensi 9 kHz-150 kHz. Pengukuran tersebut bertujuan untuk mengetahui perubahan karakteristik disturbansi yang dihasilkan pada saat beberapa peralatan rumah tangga dioperasikan secara simultan. Peralatan yang diuji adalah: (1) pendingin ruang inverter (2) kulkas inverter (3) kompor induksi (4) lampu LED. Jenis pengukuran yang dilakukan, diantaranya: (1) pengukuran tunggal (2) simultan dua beban (3) simultan tiga beban. Pada pengukuran simultan dua beban, beban yang diukur merupakan peralatan inveter yang dikombinasikan dengan peralatan non-inverter. Pada pengukuran simultan tiga beban pengukuran dikelompokan menjadi kelompok interaksipendingin ruang inverter-kompor induksi-lampu LED dan kelompok interaksi kulkas inverter kompor induksi-lampu LED.
Pengukuran dilakukan dengan menggunakan divais Picoscope dan perangkat lunak Matlab kemudian direpresentasikan dalam domain frekuensi. Pada pengukuran tunggal, peralatan rumah tangga inverter menghasilkan tegangan disturbansi dominan pada beberapa frekuensi yang berbeda, sedangkan kompor induksi dan lampu LED hanya menghasilkan disturbansi pada satu frekuensi. Hasilpengukuran simultan dua dan tiga beban adalah terukur disturbansi pada frekuensi yang sama dengan frekuensi disturbansi yang dihasilkan oleh masing-masing peralatan rumah tangga invertersaat dioperasikan tunggal, namun nilai disturbansi yang dihasilkan mengalami penurunan, kenaikan level, dan pergeseran frekuensi.

The inverter-implemented household appliance not only improves energy efficiency but also generates disturbance. It emits disturbance through the conductors known as conducted emission. Disturbance characteristic of every appliance is unique, yet on the frequency range 9 kHz-150 kHz. The regulation regarding generated disturbance level on those frequency is limited. The appliance operated simultaneously will connected each other inresidential electrical network. Those appliances tents to interact. Generated disturban cewhile operate simultaneously will be different to singular operation. Disturbance measurement is conducted on this study purposed to find charteristic disturbance when the appliance soperated simultaneously.
This study investigates generated disturbance on frequency range 9 kHz-150 kHz. There some appliances are tested: Air-conditioner and refrigerator which are equipped with inverter system, induction cooker, and LED bulb lamps. The test is conducted when the appliance operated singularly, simultaneously with another appliance, and simultan eously with two other appliances. The test of simultaneous with another appliance is conducted when two appliances operated, while test of simultaneous with other applianceis conducted when three appliances operated. On the test of simutaneos with otherappliance, it is grouped into simultaneous Air conditioner-induction cooker-LED bulb lamps and refrigerator-induction cooker-LED bulb lamps.
The test is measured by Picoscope device and represent by Matlab on frequency domain. The disturbance characteristic of singular operation for inverting appliance generates disturbance on some frequencies, whereas induction cooker and LED lamp bulb generated only in one frequency. The simultaneous operation generated disturbance charracterictic similar with singular operation of inverter appliance, yet some disturbance levelsareincreased, decreased, evenmore some frequencies shifted.

 File Digital: 1

Shelf
 S-Zainal Abidin.pdf :: Unduh

LOGIN required

 Metadata

No. Panggil : S-Pdf
Entri utama-Nama orang :
Entri tambahan-Nama orang :
Subjek :
Penerbitan : Depok: Fakultas Teknik Universitas Indonesia, 2019
Program Studi :
Bahasa : ind
Sumber Pengatalogan : LibUI ind rda
Tipe Konten : text
Tipe Media : computer
Tipe Carrier : online resource
Deskripsi Fisik : x, 70 pages : illustration
Naskah Ringkas :
Lembaga Pemilik : Universitas Indonesia
Lokasi : Perpustakaan UI
  • Ketersediaan
  • Ulasan
No. Panggil No. Barkod Ketersediaan
S-Pdf 14-21-778730648 TERSEDIA
Ulasan:
Tidak ada ulasan pada koleksi ini: 20481464