ABSTRAK
Populasi DKI Jakarta pada tahun 2018 adalah 10467629 sementara total wilayah DKI Jakarta tetap di 662,33 KM2. Ini menunjukkan bahwa penggunaan SIG sangat cocok untuk digunakan di daerah padat penduduk dengan lahan sempit. Media isolasi dalam GIS adalah SF6. gas, oleh karena itu kualitas SF6. gas perlu dipertimbangkan. Analisis dan pengetahuan terkait SF6. kualitas gas diperlukan. Metode yang digunakan adalah Metode Magnus yang menggunakan parameter titik embun dan kadar air untuk menentukan kualitas gas SF6. Dengan mengetahui bahwa parameter ini dapat dinilai baik atau tidak kinerja GIS (Gas Insulated Switchgear). Prediksi usia SF6. operasi gas dilakukan dengan menggunakan metode Time To Failure (TTF) yang mengukur tekanan di setiap kompartemen dalam 10 tahun terakhir. Kemudian akan diproses dan berapa banyak waktu yang tersisa untuk GIS (Gas Insulated Switchgear) sebelum kegagalan terjadi. Hasil penelitian menunjukkan bahwa kualitas GIS di unit CSW Bulungan memiliki nilai terburuk di teluk Karet 2 - CB Main dengan nilai kadar air 283,5 ppmv dan titik embun -22,61 ° C. Prediksi usia operasi gas terburuk juga ditemukan di teluk Karet 2 - CB Main dengan usia operasi 11 tahun

ABSTRACT
The population of DKI Jakarta in 2018 is 10467629 while the total area of ​​DKI Jakarta remains at 662.33 KM2. This shows that the use of GIS is very suitable for use in densely populated areas with narrow land. Isolation media in GIS is SF6. gas, therefore SF6 quality. gas needs to be considered. Analysis and knowledge related to SF6. gas quality is required. The method used is the Magnus Method which uses the parameters of dew point and moisture content to determine the quality of SF6 gas. By knowing that this parameter can be assessed whether or not the performance of GIS (Gas Insulated Switchgear). Age prediction for SF6. Gas operations are carried out using the Time To Failure (TTF) method which measures the pressure in each compartment in the past 10 years. Then it will be processed and how much time is left for the GIS (Gas Insulated Switchgear) before the failure occurs. The results showed that the quality of GIS in the CSW Bulungan unit had the worst value at Karet 2 - CB Main bay with a moisture content of 283.5 ppmv and a dew point of -22.61 ° C. CB Main is 11 years old

 File Digital: 1

Shelf
 S-Ratri Prajwalita Dewimaruto.pdf :: Unduh

 Metadata

No. Panggil : S-Pdf
Entri utama-Nama orang :
Entri tambahan-Nama orang :
Entri tambahan-Nama badan :
Subjek :
Penerbitan : [Place of publication not identified]: [Publisher not identified], 2019
Program Studi :
Bahasa : ind
Sumber Pengatalogan : LibUI ind rda
Tipe Konten : text
Tipe Media : computer
Tipe Carrier : online resource
Deskripsi Fisik : xii, 171 pages ; illustrations ; 30 cm
Naskah Ringkas :
Lembaga Pemilik : Universitas Indonesia
Lokasi : Perpustakaan Uiniversitas Indonesia. Lantai 3
  • Ketersediaan
  • Ulasan
No. Panggil No. Barkod Ketersediaan
S-Pdf 14-21-046611186 TERSEDIA
Ulasan:
Tidak ada ulasan pada koleksi ini: 20488822