Analisis respon getaran dari gedung rumah sakit bertingkat tinggi yang menggunakan high damping rubber bearing pada fondasinya saat mendapat paparan gempa bumi = Vibration response analysis on high rise hospital building that uses high damping rubber bearing on its foundation that is subjected to earthquake excitation

Firhan Rizki Hardian; Wahyu Nirbito, supervisor; Imansyah Ibnu Hakim, examiner; Mohammad Adhitya, examiner; Radon Dhelika, examiner (Fakultas Teknik Universitas Indonesia, 2019)

 Abstrak

Pada sebuah rumah sakit pendidikan yang dipenuhi oleh pasian, petugas kesehatan, serta berbagai peralatan dan fasilitas kesehatan lainnya, respon bangunan akibat gempa sangatlah berbahaya. Untuk mengurangi korban nyawa maupun kerusakan infrastruktur, digunakan sebuah base isolation yang dipasang pada pondasi gedung. Base isolation dalam bentuk laminated rubber bearing berfungsi untuk mengubah gerakan kantilever bangunan saat merespon gempa menjadi lateral, untuk menjaga isi bangunan dalam keadaan yang aman. Berapa perhitungan dari parameter respon getaran dilakukan untuk menentukan karakteristik optimal dari base isolation. Nilai Keq yaitu 415,120,000 N/m dan massa total dari bangunan rumah sakit adalah 739,534,249.7 kg, serta gaya eksitasi gempa terbesar bernilai 4,015,079,348.47 N. Tujuan dari penelitian ini adalah untuk mensimulasikan gerakan lateral bangunan akibat base isolation akibat pengaruh gempa, dan menentukan apakah respon sudah memenuhi kriteria perancangan.

In a teaching hospital that is full of patients, medical personnel, medical treatment facilities as well as many modern advanced equipment, the response of the building due to earthquake might be very dangerous. To reduce victims and damages in infrastructure, a form of base isolation is applied to the foundation of the building. The base isolation, in form of a laminated rubber bearing, creates a lateral motion of the building when receiving earthquake forces in order to keep the people and equpments safe. Some calculations of the response vibration parameters are observed to determine the optimum properties of the base isolation. The Keq Value is 415,120,000 N/m and the total mass of the hospital is 739,534,249.7 kg as well as the highest vibration force is 4,015,079,348.47 N. The aim of this research is to simulate the lateral motion of the building with base isolation, due to earthquake forces and decide wether the response is as expected of the design.

 File Digital: 1

Shelf
 S-Firhan Rizki Hardian.pdf :: Unduh

LOGIN required

 Metadata

No. Panggil : S-pdf
Entri utama-Nama orang :
Entri tambahan-Nama orang :
Entri tambahan-Nama badan :
Subjek :
Penerbitan : Depok: Fakultas Teknik Universitas Indonesia, 2019
Program Studi :
Bahasa : ind
Sumber Pengatalogan : LibUI ind rda
Tipe Konten : text
Tipe Media : computer
Tipe Carrier : online resource
Deskripsi Fisik : xii, 34 pages : illustration
Naskah Ringkas :
Lembaga Pemilik : Universitas Indonesia
Lokasi : Perpustakaan UI
  • Ketersediaan
  • Ulasan
No. Panggil No. Barkod Ketersediaan
S-pdf 14-22-56715282 TERSEDIA
Ulasan:
Tidak ada ulasan pada koleksi ini: 20489890