:: UI - Skripsi Membership :: Kembali

UI - Skripsi Membership :: Kembali

Analisis pelayanan radiologi dengan pendekatan lean six sigma di Rumah Sakit Hermina Tangerang tahun 2019 = Radiology service analysis with lean six sigma approach at Hermina Tangerang Hospital in 2019

Khansa Aidah; Masyitoh, supervisor; Adik Wibowo, examiner; Dede Setyadi, examiner (Fakultas Kesehatan Masyarakat Universitas Indonesia, 2019)

 Abstrak

Penelitian bertujuan untuk mengidentifikasi alur proses pelayanan dengan menggunakan pendekatan lean six sigma dan memberikan usulan perbaikan di Instalasi Radiologi RS Hermina Tangerang. Penelitian ini merupakan penelitian operasional (operational research) dengan desain penelitian kuantitatif dan kualitatif yang didapatkan dari hasil observasi, wawancara mendalam, dan telaah dokumen. Sasaran penelitian adalah pemeriksaan radiologi konvensional sebanyak 31 sampel. Hasil yang didapatkan dari pengukuran value stream mapping (VSM) adalah rata-rata lead time per pasien 2 jam 26 menit 42 detik pada shift pagi siang dan 12 jam 34 menit 53 detik pada shift malam. Bottleneck terletak pada siklus pengolahan ekspertise dikontribusi oleh sebagian besar waste of waiting, yaitu menunggu foto dibaca oleh dokter spesialis radiologi. Akar penyebab masalah adalah tidak ada jam praktek dokter spesialis radiologi pada shift malam hari serta belum diterapkan standarisasi waktu tunggu pelayanan radiologi untuk semua jenis pasien. Usulan perbaikan yang diberikan adalah dilakukannya standardized work, visual management, dan just in time sehingga diestimasikan lead time dapat dikurangi sebesar 26,47% (1 jam 47 menit 52 detik) pada shift pagi dan siang, serta shift malam 49,35% (6 jam 22 menit 28 detik).

The purpose of this study is to identify the service process flow using lean six sigma approach and giving improvement suggestions in radiology instalation at Hermina Tangerang Hospital. This is a quantitative and qualitaive operational research which the data was collected from observation result, in-depth interview, and document review. Target research of the study was the coventional radiology examinations with 31 samples. The result based on value stream mapping (VSM) measurement showed the average lead time per patient is 2 hours 26 minutes 42 seconds in the day shift and 12 hours 34 minutes 53 seconds in the night shift. The bottleneck is located in the expertise processing cyle which dominantly contributed by waste of waiting by waiting the image to be interpreted by the radiology specialist doctor. The root cause of the problem was the unavailability of the radiology specialist doctor in the night shift and there is no standardization of patients waiting time in the radiology services.  The improvement suggestions are the radiology department needs to apply a standardized work, visual management, and just in time, so that it is estimated that the lead time can be reduced 26,47% (1 hour 47 minutes 52 seconds) in the day shift and 49,35% in the night shift (6 hours 22 minutes 28 seconds).

 File Digital: 1

Shelf
 S-Pdf Khansa Aidah.pdf :: Unduh

LOGIN required

 Metadata

No. Panggil : S-pdf
Entri utama-Nama orang :
Entri tambahan-Nama orang :
Entri tambahan-Nama badan :
Subjek :
Penerbitan : Depok: Fakultas Kesehatan Masyarakat Universitas Indonesia, 2019
Program Studi :
Bahasa : ind
Sumber Pengatalogan : LibUI ind rda
Tipe Konten : text
Tipe Media : computer
Tipe Carrier : online resource
Deskripsi Fisik : xvi, 189 pages : illustration ; appendix
Naskah Ringkas :
Lembaga Pemilik : Universitas Indonesia
Lokasi : Perpustakaan UI
  • Ketersediaan
  • Ulasan
No. Panggil No. Barkod Ketersediaan
S-pdf 14-21-647532108 TERSEDIA
Ulasan:
Tidak ada ulasan pada koleksi ini: 20494685