Electrogenerated Chemiluminescence (ECL) Luminol/Karbonat pada Elektroda Quasi Screen-Printed Boron-doped Diamond (SPE-BDD) = Electrogenerated Chemiluminescence (ECL) of Luminol/Carbonate on Quasi Screen-Printed Boron-doped Diamond Electrode (SPE-BDD) / Isnaini Rahmawati
Isnaini Rahmawati, examiner;
Ivandini Tribidasari Anggraningrum, supervisor; Endang Saefudin, examiner; Yoki Yulizar, examiner; Iman Abdullah, examiner; Budiawan, examiner
([Publisher not identified]
, 2020)
|
ABSTRAK Sebuah elektroda mini dengan volume analit kecil sekitar 30 μL difabrikasi dengan menggunakan elektroda Boron-doped Diamond (BDD) sebagai elektroda kerja. Elektroda tersebut mempunyai luas permukaan sebesar 0,3 cm2 diukur dengan menggunakan persamaan Randles-sevcick dan dapat digunakan sebagai sel dalam pengukuran ECL dengan diamatinya sinyal ECL pada penggunaan PMT sebesar 3 V. Sistem ECL menggunakan luminol dalam Na2CO3 pada elektroda BDD telah dipelajari sebelumnya oleh Rais (2019). Pada penelitian ini luminol dalam Na2CO3 dipelajari lebih lanjut dan digunakan untuk menentukan konsentrasi karbonat maupun CO2 dalam sampel yaitu sebesar 11,63 mM untuk air karbonasi rasa lemon, 7,98 mM untuk air berkarbonasi biasa, serta 5,67 mM untuk CO2 jenuh dalam larutan. Mengacu pada hasil luminol dalam Na2CO3 tersebut, elektroda mini tersebut dipelajari sebagai sel elektrokimia pada sistem ECL menggunakan luminol dalam Na2CO3 dan memiliki ketahanan yang baik setelah 90 hari pemakaian. ABSTRACT A mini electrode with a small volume of analytes around 30 μL is fabricated using Boron-doped Diamond (BDD) electrode as a working electrode. The electrode has a surface active area of 0.3 cm2 measured by Randles-sevcick equation and can be used as a cell in ECL measurements as ECL signals can be observed. ECL systems using luminol in Na2CO3 on BDD electrodes have been studied previously by Rais (2019). In this study, luminol in Na2CO3 was further studied to determine carbonate and CO2 concentrations in the sample, which was 11.63 mM for lemon flavored carbonation water, 7.98 m for ordinary carbonated water, and 5.67 m for saturated CO2 in solution. Referring to the results of luminol in Na2CO3, the mini electrode was studied as electrochemical cells in the ECL system using luminol in Na2CO3 and has good durability after 90 days of use. |
T54722-Isnaini Rahmawati.pdf :: Unduh
|
No. Panggil : | T54722 |
Entri utama-Nama orang : | |
Entri tambahan-Nama orang : | |
Entri tambahan-Nama badan : | |
Subjek : | |
Penerbitan : | [Place of publication not identified]: [Publisher not identified], 2020 |
Program Studi : |
Bahasa : | ind |
Sumber Pengatalogan : | LibUI ind rda |
Tipe Konten : | text |
Tipe Media : | unmediated ; computer |
Tipe Carrier : | volume ; online resource |
Deskripsi Fisik : | xiii, 55 pages : illustration ; 28 cm + appendix |
Naskah Ringkas : | |
Lembaga Pemilik : | Universitas Indonesia |
Lokasi : | Perpustakaan UI, Lantai 3 |
No. Panggil | No. Barkod | Ketersediaan |
---|---|---|
T54722 | 15-21-095730025 | TERSEDIA |
Ulasan: |
Tidak ada ulasan pada koleksi ini: 20502266 |