Kesesuaian nilai qNOX dengan perubahan hemodinamik sebagai prediktor respon nyeri pada prosedur intubasi trakea = Compatibility of qNOX value with hemodynamic changes as a predictor of pain response in tracheal intubation procedures
Nindya Anggi Sinantara;
Adhrie Sugiarto, supervisor; Arif Hari Martono Marsaban, supervisor; Ratna Farida Soenarto, supervisor; Amir Madjid, examiner; Darto Satoto, examiner; Indro Mulyono, examiner; Susilo Candra, supervisor; Pryambodho, examiner
(Fakultas Kedokteran Universitas Indonesia, 2020)
|
Latar Belakang. Pemantauan respon keadaan nosiseptif dengan objektif melalui metode non-klinis masih dalam keadaan pengujian dan pengembangan, tanpa metode yang terdokumentasi dan terbukti baik untuk penggunaan sehari-hari secara klinis. Pemantauan terhadap nosiseptif hingga saat ini lebih banyak berdasarkan status hemodinamik pasien yang dinilai dari laju nadi dan tekanan darah. qNOX telah membuktikan korelasi dengan tanda-tanda klinis dari nosiseptif dan/atau antinosiseptif yang tidak memadai, seperti gerakan selama insersi LMA, laringoskopi dan intubasi trakea Oleh karena itu, peneliti ingin mengetahui kesesuaian nilai qNOX dengan perubahan hemodinamik sebagai prediktor respon nyeri pada prosedur intubasi trakea.Metode. Penelitian merupakan penelitian reliabilitas dan diagnostik yang menilai kesesuaian nilai qNOX dengan perubahan hemodinamik sebagai prediktor respon nyeri pada prosedur intubasi trakea, dan menilai validitas qNOX sebagai prediktor respon nyeri. 54 subjek dilakukan pendataan nilai qNOX sebelum dilakukan intubasi, dan dua kali pendataan hemodinamik yaitu sebelum anestesia dan dalam satu menit pasca-intubasi. Data hemodinamik kemudian ditentukan selisihnya dan dikategorikan menjadi reaktif dan nonreaktif. Data qNOX yang didapatkan dikategorikan menjadi responsif dan nonresponsif. Hasil. Uji Kappa menunjukkan kesesuaian qNOX dengan perubahan hemodinamik adalah bermakna dengan nilai Kappa 0,715. qNOX menunjukkan sensitivitas sebesar 100% dan spesifisitas sebesar 86%.Simpulan. Terdapat kesesuaian yang kuat antara nilai qNOX dengan perubahan hemodinamik sebagai prediktor respon nyeri pada prosedur intubasi trakea. qNOX dan perubahan hemodinamik merupakan prediktor respon nyeri yang reliabel dalam prediksi respon nyeri pada prosedur intubasi trakea. qNOX memiliki sensitifitas dan spesifisitas yang tinggi sebagai prediktor respon nyeri pada prosedur intubasitrakea. Background. Objectively monitoring the response of nociceptive states through non-clinical methods is still in testing and development, without well-documented and proven methods for clinical daily use. Nociceptive monitoring to date has largely been based on the patient's hemodynamic status as measured by heart rate and blood pressure. qNOX has been shown to correlate with nociceptive and / or inadequate antinociceptive clinical signs, such as movements during LMA insertion, laryngoscopy and tracheal intubation. Therefore, researchers want to find out the suitability of qNOX values with hemodynamic changes as predictors ofpain response in tracheal intubation procedures. Method. The study is a reliability and diagnostic study that assesses the suitability of qNOX values with hemodynamic changes as predictors of pain response intracheal intubation procedures, and assesses the validity of qNOX as a predictor of pain response. 54 subjects were collected qNOX values before intubation, and hemodynamic data collection twice before anesthesia and within one minute postintubation. Hemodynamic data is then determined by the difference and categorized as reactive and nonreactive. The qNOX data obtained is categorized as responsive and non-responsive. Results. Kappa test shows that the suitability of qNOX with hemodynamic changes is significant with a Kappa value of 0.715. qNOX shows a sensitivity of 100% and a specificity of 86%. Conclusion. There is a strong compatibility between qNOX values andhemodynamic changes as predictors of pain response in tracheal intubation procedures. qNOX and hemodynamic changes are reliable predictors of pain response in the prediction of pain response in tracheal intubation procedures. qNOX has a high sensitivity and specificity as a predictor of pain response in tracheal intubation procedures. |
T-Nindya Anggi Sinantara.pdf :: Unduh
|
No. Panggil : | T-pdf |
Entri utama-Nama orang : | |
Entri tambahan-Nama orang : | |
Entri tambahan-Nama badan : | |
Subjek : | |
Penerbitan : | Depok: Fakultas Kedokteran Universitas Indonesia, 2020 |
Program Studi : |
Bahasa : | ind |
Sumber Pengatalogan : | LibUI ind rda |
Tipe Konten : | teks |
Tipe Media : | unmediated |
Tipe Carrier : | volume (rdacarier) |
Deskripsi Fisik : | xvii, 55 pages: Ilustration : appendix |
Naskah Ringkas : | |
Lembaga Pemilik : | Universitas Indonesia |
Lokasi : | Perpustakaan UI, Lantai 3 |
No. Panggil | No. Barkod | Ketersediaan |
---|---|---|
T-pdf | 15-22-54170302 | TERSEDIA |
Ulasan: |
Tidak ada ulasan pada koleksi ini: 20503742 |