:: UI - Skripsi Membership :: Kembali

UI - Skripsi Membership :: Kembali

Uji Waktu Jenuh Membran Untuk Penyediaan Air Bersih Dengan Sistem Osmosis Balik Dengan Tekanan Rejeksi Bertingkat = Saturation Time Test of Membran To Supply Clean Water Using Reverse Osmosis With Pressure Stage in Rejection

Muhammad Zakwan; Setijo Bismo, supervisor; Nelson Saksono, examiner; Yuliusman, examiner (Fakultas Teknik Universitas Indonesia, 2020)

 Abstrak

ABSTRAK
Terjadinya Tsunami pada daerah Pandeglang tahun 2018 mengakibatkan kadar garam yang tinggi, sehingga terjadi kelangkaan air. Selain itu terjadi kesulitan akses air pada 4 kecamatan di kabupaten Pandeglang pada tahun 2019 akibat musim kemarau. RO merupakan teknologi yang dapat digunakan dalam penyediaan air bersih, namun memerlukan penelitian lebih lajut untuk mengetahui cara kerja alat RO bertingkat untuk menghasilkan air bersih dan mengetahui tekanan optimum pada alat RO untuk menghasilkan air sesuai standar dan waktu jenuh membran yang lama. Penelitian secara eksperimental dengan merancang alat RO untuk dioperasikan pada daerah Tanjung Lame, dengan memvariasikan tekanan 6-3, 6-4 dan 7-4 pada tahap pertama dan kedua untuk melihat pengaruhnya terhadap penurunan laju alir dan peningkatan nilai TDS selama 72 jam. Penggunaan tekanan P1 = 6/P2 = 3 bar menunjukkan hasil yang lebih baik dibandingkan dengan penggunaan tekanan P1 = 6/P2 = 4 dan P1 = 7/ P2 = 4 bar untuk menghasilkan air minum. Penyediaan air dengan TDS 20 ppm dapat dilakukan dengan konfigurasi dua tahap dengan cara produk tahap pertama dijadikan umpan pada tahap kedua. Tekanan yang digunakan P1 = 6 bar dan P2 = 3 bar dengan waktu jenuh membran selama 72-80 jam pada tahap pertama dan 72-131 jam tahap kedua.

ABSTRACT
Tsunami in Pandeglang had resulted high salt level, resulting in water scarcity. Furthermore, there were difficulties in accessing water due to dry season in 4 sub-distric in Pandeglang in 2019. RO is suitable technology in provision clean water, but require advance research to know the method and determine optimum pressure of multi-pass RO to produce clean water with a long saturation time of membrane. An experimental research using RO multi-pass which was operated in Tanjung Lame by varying pressure 6-3, 6-4 and 7-4 on first and second stage to observe the effect of decreasing flux and enhancement of TDS throughout 72 hour. The use of pressure P1 = 6 bar/ P2 = 3 bar showed better result compared to P1 = 6/ P2 = 3 and P1 = 7/ P2 = 4 in producing clean water. Provision clean water at 20 ppm has done using RO multi-pass which permeat in first stage used as feed in second stage. Using P1 = 6 bar and P2 = 3 bar give the saturation time of membrane 72-80 hour in first stage and 72-131 hour in second stage.

 File Digital: 1

Shelf
 S-Muhammad Zakwan.pdf :: Unduh

LOGIN required

 Metadata

No. Panggil : S-pdf
Entri utama-Nama orang :
Entri tambahan-Nama orang :
Entri tambahan-Nama badan :
Subjek :
Penerbitan : Depok: Fakultas Teknik Universitas Indonesia, 2020
Program Studi :
Bahasa : ind
Sumber Pengatalogan : LibUI ind rda
Tipe Konten : text
Tipe Media : unmediated
Tipe Carrier : online resource
Deskripsi Fisik : xiv, 41 pages : illustration ; 28 cm + appendix
Naskah Ringkas :
Lembaga Pemilik : Universitas Indonesia
Lokasi : Perpustakaan UI, Lantai 3
  • Ketersediaan
  • Ulasan
No. Panggil No. Barkod Ketersediaan
S-pdf 14-22-78631100 TERSEDIA
Ulasan:
Tidak ada ulasan pada koleksi ini: 20504181