Akurasi Basal Digital Pressure, Saturasi Oksigen dan Change Digital Pressure dalam Mendiagnosa Chronic Steal Syndrome pasca Operasi Fistula Arterio-Venosa Brachiocephalica pada Pasien Penyakit Ginjal Tahap Akhir dengan Diabetes Melitus Tipe 2 = Accuracy of Basal Digital Pressure, Oxygen Saturation, and Change Digital Pressure for the diagnosis of Chronic Steal Syndrome after Brachiocephalic Arteriovenous Fistula Surgery in End-Stage Renal Disease Patient with Type 2 Diabetes Mellitus.

Ilham Arif; Dedy Pratama, supervisor; Aria Kekalih, examiner; Hilman Ibrahim, examiner; Raden Suhartono, examiner; Alexander Jayadi Utama, examiner; Patrianef Darwis, examiner; Akhmadu Muradi, examiner (Fakultas Kedokteran Universitas Indonesia, 2020)

 Abstrak

Latar belakang: Penyakit ginjal tahap akhir (PGTA) terusmeningkat jumlahnya di dunia maupun di Indonesia. Fistula arterio-venosa (FAV) masih menjadi standard emas aksesvaskular untuk hemodialisa dan untuk pasien diabetes melitusdirekomendasikan untuk membuat FAV di brakiosefalika. Steal Syndrome merupakan salah satu komplikasi FAV. Telah adapenelitian basal digital pressure (BDP), saturasi oksigen, dan change digital pressure (CDP) untuk diagnosa Steal Syndrome, namun belum pada pasien dengan diabetes melitus. Penelitianini bertujuan untuk mengukur akurasi BDP, saturasi oksigen, dan CDP untuk diagnosa Steal Syndrome pada pasien PGTA dengandiabetes melitus.
Metode: Penelitian ini merupakan kohort prospektif yang melibatkan 69 pasien PGTA dengan diabetes melitus tipe 2 yang melakukan kontruksi FAV brakiosefalika pada 3 senter vaskulardi Jakarta. Pemeriksaan BDP, CDP, dan saturasi oksigendilakukan minimal 4 minggu setelah proses pembuatan FAV dan setelah FAV dinyatakan matur serta telah digunakan untukhemodialisa. Analisis statistic menggunakan SPSS versi 25.
Hasil: Terdapat perbedaan bermakna pada CDP, BDP, maupun saturasi oksigen antara pasien Steal Syndrome dan tidak Steal Syndrome (p<0,001). Nilai area under curve (AUC) BDP, CDP, dan Saturasi oksigen untuk memprediksi Steal Syndrome adalah 95,9% (IK95%: 90,1%-100%), 93,8% (IK95%: 87,6%-99,9%), dan 97,5% (IK95%: 93,8%-100%). Dan nilai ambang batasBDP, CDP, dan saturasi oksigen yang optimal untukmemprediksi Steal Syndrome adalah <85 mmHg (sensitivitas: 80%, Spesifisitas 100%) untuk BDP, >35 mmHg (sensitivitas: 80%, Spesifisitas 90,74%) untuk CDP, dan 94,5% (sensitivitas80%, spesifisitas 100%) untuk saturasi oksigen.
Kesimpulan: BDP, CDP, dan saturasi oksigen meski dengansensitivitas dan spesifisitas yang masih terbatas terbukti dapatdigunakan untuk mendiagnosa Steal Syndrome pada pasienPGTA dengan diabetes melitus.

Background: The number of end-stage renal disease patient keep increasing globally. Arteriovenous Fistula (AVF) is still the golden standard vascular access for hemodialysis and the recommended site for AVF construction in diabetic patient is at brachiocephalic. Steal Syndrome is one of AVF complication.There have been studies that used basal digital pressure (BDP), oxygen saturation, and change digital pressure (CDP) for Steal Syndrome diagnosis. However, there is no study in diabetic patient. This study aims to measure the accuracy of BDP, CDP, and oxygen saturation to diagnose Steal Syndrome in end-stage renal disease patient with type 2 diabeters mellitus.
Methods: This is a prospective cohort study with 69 end-stage renal disease patient with type 2 diabetes mellitus that have braciocephalic AVF construction in 3 vascular centers in Jakarta. BDP, CDP, and oxygen saturation examination was performed after AVF was considered mature and being use for hemodialysis, the earliest being 4 weeks after AVF construction.SPSS version 25 was used for statictical analysis.
Result: There was significant association between CDP, BDP,and oxygen saturation with Steal Syndrome (p<0,001). Area Under Curve (AUC) value of BDP, CDP, and oxygen saturation to predict Steal Syndrome was 95,9% (90,1%-100%), 93,8% (87,6%-99,9%), and 97,5% (93,8%-100%) consecutively. The optimal threshold of BDP, CDP, and oxygen saturation for predicting steal syndrome was <85 mmHg (sensitivity: 80%, Spesificity 100%) for BDP, >35 mmHg (sensitivity: 80%, Spesificity 90,74%) for CDP, dan 94,5% (sensitivity 80%, spesificity 100%) for oxygen saturation.
Conclusion: BDP, CDP, and oxygen saturation can be used to diagnose Steal Syndrome in end-stage renal disease patient with diabetes mellitus. However, BDP, CDP, and oxygen saturation still have limited sensitivity and specificity.

 File Digital: 1

Shelf
 T-Ilham Arif.pdf :: Unduh

LOGIN required

 Metadata

No. Panggil : T-Pdf
Entri utama-Nama orang :
Entri tambahan-Nama orang :
Entri tambahan-Nama badan :
Subjek :
Penerbitan : Jakarta: Fakultas Kedokteran Universitas Indonesia, 2020
Program Studi :
Bahasa : ind
Sumber Pengatalogan : LibUI ind rda
Tipe Konten : text
Tipe Media : computer
Tipe Carrier : online resource
Deskripsi Fisik : xviii, 41 pages : illustration ; 28 cm. + appendix
Naskah Ringkas :
Lembaga Pemilik : Universitas Indonesia
Lokasi : Perpustakaan UI, Lantai 3
  • Ketersediaan
  • Ulasan
No. Panggil No. Barkod Ketersediaan
T-Pdf 15-22-10922710 TERSEDIA
Ulasan:
Tidak ada ulasan pada koleksi ini: 20504257