Analisis Performa Evacuated Tube Solar Collector pada Pengaruh Susunan Rangkaian Seri-Paralel = Performance analysis of evacuated tube solar collectors on a series-parallel arrangement effects.

Alwi Ahmad Al Muhdar; Muhammad Idrus Alhamid, supervisor; Lubis, Arnas, supervisor; Nasruddin, examiner; Budihardjo, examiner (Fakultas Teknik Universitas Indonesia, 2020)

 Abstrak

Kebutuhan akan sumber daya energi semakin meningkat tiap tahunnya. Kolektor surya mampu menyerap radiasi matahari dan sebagai pemanas air. Untuk mendapatkan energi yang banyak, maka diperlukan juga kolektor surya yang banyak. Kolektor surya dengan jenis evacuated tube solar collector  pada atap gedung MRC FTUI terpasang secara seri-paralel dengan detail dua kolektor surya dipasang secara seri baru diparalelkan. Penelitian ini akan melakukan simulasi dengan software bernama MATLAB dengan tujuan mengetahui apakah jika susunan rangkaiannya dirubah akan mendapatkan hasil temperatur akhir yang lebih baik. Dalam penelitian ini, dilakukan simulasi dengan beberapa kondisi, untuk mengetahui apabila susunan rangkaian dirubah dapat meningkatkan temperatur akhirnya. Setelah didapatkan hasil, dilakukan simulasi kembali untuk mencari susunan rangkaian yang memiliki temperatur keluar yang lebih tinggi dari susunan sebelumnya. Dengan menggunakan data rata-rata susunan rangkaian baru didapatkan dengan selisih temperatur masuk dan keluar sebesar  10,3 oC, sedangkan rangkaian aktual saat ini memiliki selisih temperatur sebesar 6,3 oC. Efisiensi yang didapatkan pada rangkaian baru sebesar 67,4% dan rangkaian aktual yang terpasang saat ini sebesar 67,9%.

The need for energy resources is increasing every year. The solar collector can absorb solar radiation and as a water heater. To get a lot of energy, we need a lot of solar collectors. Evacuated tube solar collectors on the roof of the FTUI MRC building installed in parallel-series with the details of the two solar collectors installed in a new series paralleled. This study will conduct a simulation with MATLAB software to know whether the arrangement of the circuit is changed will get a better final temperature. In this study, a simulation was carried out with several conditions to determine if the arrangement of the circuit altered could increase the final temperature. After the results obtained, the simulation performed again to find the circuits arrangement with a higher exit temperature than the previous arrangement. By using average data, the arrangement of the new circuit obtained by the difference in temperature in and out of 10.3 oC. In comparison, the actual circuit currently has a temperature difference of 6.3 oC. The efficiency obtained in the new circuit is 67.4%, and the currently installed circuit is 67.9%. 

 File Digital: 1

Shelf
 S-Alwi Ahmad Al Muhdar.pdf :: Unduh

LOGIN required

 Metadata

No. Panggil : S-pdf
Entri utama-Nama orang :
Entri tambahan-Nama orang :
Entri tambahan-Nama badan :
Subjek :
Penerbitan : Depok: Fakultas Teknik Universitas Indonesia, 2020
Program Studi :
Bahasa : ind
Sumber Pengatalogan : LibUI ind rda
Tipe Konten : text
Tipe Media : computer
Tipe Carrier : online resource
Deskripsi Fisik : xii, 42 pages : illustration ; appendix
Naskah Ringkas :
Lembaga Pemilik : Universitas Indonesia
Lokasi : Perpustakaan UI
  • Ketersediaan
  • Ulasan
No. Panggil No. Barkod Ketersediaan
S-pdf 14-22-84504717 TERSEDIA
Ulasan:
Tidak ada ulasan pada koleksi ini: 20505842