Kualitas bakteri udara di ruang operasi di beberapa rumah sakit di Jakarta dan sekitarnya tahun 2018-2019 = Quality of air bacteria in operating room in several hospitals in Jakarta and the greater area of Jakarta in 2018-2019
Nabila Naura Vathania;
Conny Riana Tjampakasari, supervisor; Tjahjani Mirawati Sudiro, examiner
([Publisher not identified]
, 2019)
|
ABSTRAK Infeksi nosokomial dapat meningkatkan morbiditas dan mortalitas pasien, terutama di ruang operasi dan ICU, di mana terdapat aktivitas yang tinggi. Perlu adanya pemantauan dan penjagaan kualitas udara secara bakteriologi sebagai cerminan dari kondisi kebersihan di rumah sakit. Tujuan dari penelitian ini adalah mengetahui kualitas udara secara bakteriologi di ruang operasi di beberapa rumah sakit di Jakarta dan sekitarnya sebagai salah satu langkah pencegahan infeksi nosokomial. Desain penelitian ini adalah retroprospektif dengan menggunakan data yang bersumber dari UKK PPM LMK FKUI. Data diperoleh dari 217 pemeriksaan di ruang operasi dan 5 pemeriksaan di ICU yang dilakukan di 17 rumah sakit selama Januari 2018-Juni 2019. Pada tahun 2018, dari 137 pemeriksaan di ruang operasi, 120 (87,59%) di antaranya memenuhi standar baku mutu dan dari 4 pemeriksaan di ICU, 1 (25%) di antaranya memenuhi standar baku. Pada tahun 2019, dari 80 pemeriksaan di ruang operasi, 70 (87,50%) di antaranya memenuhi standar baku dan dari 1 pemeriksaan di ICU, 1 (100%) memenuhi standar baku. Mayoritas ruang operasi di rumah sakit di Jakarta dan sekitarnya memiliki kualitas udara secara bakteriologi yang sudah baik, tetapi ICU memiliki kualitas udara yang tidak memenuhi standar baku mutu. ABSTRACT Nosocomial infection is known to increase morbidity and mortality of patients, especially in operating room (OR) and intensive care unit (ICU) as they have high rate of activities that may risk in infection. Monitoring and maintenance of bacteriological quality of air are needed as they can reflect the actual condition of hygiene in hospital. The aim of this study is to know the bacteriological quality of air in several hospitals in Jakarta and the greater area of Jakarta. It is expected that the results of this study can become a basis in taking preventive measures against nosocomial infection. The design of this study was retroprospective. Data were collected from 217 examinations in OR and 5 examinations in ICU done in 17 hospitals between January 2018 and June 2019 by UKK PPM LMK FKUI. In 2018, among 137 results collected in OR, 120 (87,59%) fulfilled the requirement of bacteriological quality of air and among 4 examinations done in ICU, 1 (25%) also fulfilled the requirement. In 2019, among 80 examinations done in OR, 70 (87,50%) fulfilled the requirement and among 1 check done in ICU, 1 (100%) also fulfilled the requirement. It is concluded that the bacteriological quality of air in majority of OR in hospitals in Jakarta and its greater area is good, but that in ICU is not. |
S-Nabila Naura Vathania.pdf :: Unduh
|
No. Panggil : | S-Pdf |
Entri utama-Nama orang : | |
Entri tambahan-Nama orang : | |
Entri tambahan-Nama badan : | |
Subjek : | |
Penerbitan : | [Place of publication not identified]: [Publisher not identified], 2019 |
Program Studi : |
Bahasa : | ind |
Sumber Pengatalogan : | LibUI ind rda |
Tipe Konten : | text |
Tipe Media : | computer |
Tipe Carrier : | online resource |
Deskripsi Fisik : | xii, 150 pages : illustration |
Naskah Ringkas : | |
Lembaga Pemilik : | Universitas Indonesia |
Lokasi : | Perpustakaan UI |
No. Panggil | No. Barkod | Ketersediaan |
---|---|---|
S-Pdf | 14-21-437222487 | TERSEDIA |
Ulasan: |
Tidak ada ulasan pada koleksi ini: 20509462 |