Redesain waste water treatment facility pada perusahaan farmasi = Redesign of waste water treatment facility in pharmaceutical companies

Wildan Arief Rohdina; Sutrasno Kartohardjono, supervisor; Jaka Fajar Fatriansyah, examiner (Fakultas Teknik Universitas Indonesia, 2020)

 Abstrak

Waste water treatment facility atau instalasi pengolahan air limbah merupakan salah satu
komponen penunjang yang harus dimiliki oleh setiap industri dalam rangka
melaksanakan kewajiban undang-undang yaitu Keputusan Mentri Negara Lingkungan
Hidup dan Kehutanan No 16 tahun 2019 tentang perubahan kedua atas peraturan menteri
lingkungan hidup No 5 tahun 2014 tentang baku mutu air limbah. PT Chemitra Abadi
melakukan evaluasi terhadap fasilitas pengolahan air limbah yang sudah ada dan menemukan
beberapa permasalahan terutama warna dan turbidity yang masih tinggi, konfigurasi sistem
pengolahan yang tidak sesuai dengan semestinya. Setelah dilakukan jartest untuk menentukan
dosis optimum chemical treatment yang akan digunakan maka didapat dosis optimum untuk PAC
100 ppm, Polimer anionic 7 ppm, DCA 250 ppm dan NaOH 200 ppm. Kemudian memberikan
saran konfigurasi alternatif fasilitas pengolahan air limbah yang dapat digunakan dengan
memanfaatkan fasilitas yang ada dengan merubah urutan proses.

The treatment facility or wastewater treatment installation is one of the
supporting components that must be owned by every industry in order to carry out
statutory obligations, namely the Decree of the State Minister for Environment and
Forestry No. 16 of 2019 concerning the second amendment to the regulation of the
minister of environment No. 5 years 2014 concerning wastewater quality standards. PT
Chemitra Abadi evaluated the existing wastewater treatment facilities and found several
problems, especially the color and high turbidity, and the configuration of the treatment
system that was not properly configured. After the jar test was carried out to determine
the optimum dose of chemical treatment to be used, the optimum dose was obtained for
100 ppm PAC, 7 ppm anionic polymer, 250 ppm DCA and 200 ppm NaOH. Then
provide suggestions for alternative configurations of wastewater treatment facilities that
can be used by utilizing existing facilities by changing the process sequence.

 File Digital: 1

Shelf
 TA-Wildan Arief Rohdina.pdf :: Unduh

LOGIN required

 Metadata

No. Panggil : TA-pdf
Entri utama-Nama orang :
Entri tambahan-Nama orang :
Entri tambahan-Nama badan :
Subjek :
Penerbitan : Jakarta: Fakultas Teknik Universitas Indonesia, 2020
Program Studi :
Bahasa : ind
Sumber Pengatalogan : lib ind rda
Tipe Konten : text
Tipe Media : computer
Tipe Carrier : online resource (rdacarries)
Deskripsi Fisik : (14) 29 pages ; 30 cm
Naskah Ringkas :
Lembaga Pemilik : Universitas Indonesia
Lokasi : Perpustakaan UI
  • Ketersediaan
  • Ulasan
No. Panggil No. Barkod Ketersediaan
TA-pdf 16-22-03595504 TERSEDIA
Ulasan:
Tidak ada ulasan pada koleksi ini: 20516978