:: UI - Skripsi Membership :: Kembali

UI - Skripsi Membership :: Kembali

Perbandingan Kinerja Fotodetektor Berbasis ZnO Nanorods dan Nanotubes = Performance Comparison of ZnO Nanorods and Nanotubes Based Photodetector

Alma Setiana Khoirunnisa; Vivi Fauzia, supervisor; Azwar Manaf, examiner; Djati Handoko, examiner (Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2021)

 Abstrak

Pada penelitian ini telah dilakukan sintesis ZnO nanorods (NR) 4 jam dan ZnO nanotubes (NT) dengan variasi waktu self-etching 18 jam dan 22 jam dan diapikasikan sebagai devais detektor UV 365 nm. Nanomaterial ini telah disintesis menggunakan metode ultrasonic spray pyrolysis (USP) dan hydrothermal. ZnO NT telah berhasil disintesis melalui proses self-etching ZnO NR yang tidak mengalami perubahan fasa kristal, parameter kisi maupun energi band gap. Namun demikian ZnO NT yang dihasilkan memiliki lebih banyak cacat kristal yang diindikasikan dengan kurva absorbansi optik yang lebih lebar pada daerah cahaya tampak. Hal ini menyebabkan penurunan photocurrent yang lebih tinggi daripada penuruan dark current , yang menyebabkan penurunan kinerja fotodetektor UV. Nilai sensitivitas ZnO NR menurun dari 43,74% menjadi 29,20% dan 30,80% pada sampel ZnO NT 18 jam dan 22 jam. Demikian pula nilai responsivitas menurun dari 5,83 A/W menjadi 3,09 A/W dan 4,06 A/W dan nilai detektivitas menurun dari 1,20×106 Jones menjadi 0,71×106 Jones dan 0,84×106 Jones.

In this study, the synthesis of ZnO nanorods (NR) and ZnO nanotubes (NT) with variations in self-etching time of 18 h and 22 h was carried out and applied as a UV detector device. This nanomaterial has been synthesized using ultrasonic spray pyrolysis (USP) and hydrothermal methods. ZnO NT has been successfully synthesized through the self-etching process of ZnO NR which does not change the crystal phase, lattice parameters or band gap energy. However, the resulting ZnO NT has more crystal defects indicated by a wider optical absorbance curve in the visible light region. This results in a higher photocurrent IL than an dark current ID, leading to a decrease in the performance of the UV photodetector. The sensitivity of ZnO NR decreased from 43.74% to 29.20% and 30.80% in samples of ZnO NT 18 h and 22 h. Likewise, the responsivity value decreased from 5.83 A/W to 3.09 A/W and 4.06 A/W and the detectivity value decreased from 1.20×106 Jones to 0.71×106 Jones and 0.84×106. Jones.

 File Digital: 1

Shelf
 S-Alma Setiana Khoirunnisa.pdf :: Unduh

LOGIN required

 Metadata

No. Panggil : S-pdf
Entri utama-Nama orang :
Entri tambahan-Nama orang :
Entri tambahan-Nama badan :
Subjek :
Penerbitan : Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2021
Program Studi :
Bahasa : ind
Sumber Pengatalogan : LibUI ind rda
Tipe Konten : text
Tipe Media : computer
Tipe Carrier : online resource
Deskripsi Fisik : 37 pages : illustration
Naskah Ringkas :
Lembaga Pemilik : Universitas Indonesia
Lokasi : Perpustakaan UI
  • Ketersediaan
  • Ulasan
No. Panggil No. Barkod Ketersediaan
S-pdf 14-22-66564770 TERSEDIA
Ulasan:
Tidak ada ulasan pada koleksi ini: 20525924