:: UI - Tugas Akhir :: Kembali

UI - Tugas Akhir :: Kembali

Pengaruh Kadar Hemoglobin Terhadap Keberhasilan Proses Penyapihan dan Ektubasi pada Pasien Kritis dengan Ventilasi Mekanik: Sebuah Telaah Sistematis = Effect of Hemoglobin Levels on The Success of Weaning and Extubation Processes in Critical Patients with Mechanical Ventilation: A Systematic Review

Slamet Agus Waluyo Jati; Dita Aditianingsih, supervisor; Yohanes Wolter Hendrik George, supervisor; Bambang Wahjuprajitno, examiner; Vera Irawany, examiner; Arif Hari Martono Marsaban, examiner; Bambang Wahjuprajitno, examiner; Sidharta Kusuma Manggala, examiner (Fakultas Kedokteran Universitas Indonesia, 2022)

 Abstrak

Latar Belakang: Anemia atau kadar hemoglobin yang menurun dari nilai normalnya merupakan permasalahan yang biasa terjadi pada pasien kritis di Intensive Care Unit (ICU) dan 61% pasien anemia membutuhkan ventilasi mekanik. Anemia dapat mengganggu kemampuan ventilasi selama proses penyapihan dan ekstubasi. Namun pengaruh dari kadar hemoglobin yang menurun ini masih belum jelas dan diperdebatkan oleh karena itu telaah sistematis ini dibuat untuk mengambil kesimpulan apakah kadar hemoglobin berpengaruh terhadap proses penyapihan dan ekstubasi pada pasien kritis dengan ventilasi mekanik berdasarkan penelitian-penelitian yang tersedia.
Tujuan: Mengetahui efek kadar hemoglobin terhadap proses penyapihan dan ekstubasi pada pasien kritis dengan ventilasi mekanik.
Metode: Dengan menggunakan kata kunci spesifik, dilakukan pencarian artikel potensial secara komprehensif pada PubMed, EMBASE, Scopus dan Cochrane database dengan pembatasan waktu 2013 sampai dengan 2022. Protokol studi ini telah di registrasi di PROSPERO (CRD42022336646) pada tanggal 7 Agustus 2022.
Hasil: Total 7 penelitian dengan 2.054 pasien dengan ventilasi mekanik memenuhi kriteria untuk penelitian ini dan dimasukkan dalam tinjauan sistematis. Setelah pemeriksaan database menyeluruh, dilaposkan satu studi tidak menemukan korelasi antara hemoglobin dan keberhasilan proses penyapihan dan ekstubasi. Enam penelitian menyatakan bahwa kadar hemoglobin berhubungan dengan keberhasilan proses penyapihan dan ekstubasi pada pasien sakit kritis dengan ventilasi mekanik. Penelitian ini menyimpulkan bahwa kadar hemoglobin mempengaruhi proses penyapihan dan ekstubasi pada pasien sakit kritis dengan ventilasi mekanik. Namun, diperlukan lebih banyak penelitian untuk mengkonfirmasi hasil tinjauan sistematis ini.
Kesimpulan: Penelitian ini menyimpulkan kadar hemoglobin mempengaruhi proses penyapihan dan ekstubasi pada pasien kritis dengan ventilasi mekanik. Namun dibutuhkan penelitian yang lebih banyak untuk mengkonfirmasi hasil telaah sistematis ini.

Background: Anemia or hemoglobin levels that decrease from average values ​​is a common problem in critical Intensive Care Unit (ICU) patients, and 61% of anemic patients require mechanical ventilation. Anemia can impair ventilation ability during weaning and extubation. However, the effect of decreased hemoglobin levels is still unclear and debated; therefore, this systematic review was made to conclude whether hemoglobin levels affect weaning and extubation processes in critically ill patients with mechanical ventilation based on available studies.
Objective: To determine the effect of hemoglobin levels on the process of weaning and extubation in critically ill patients with mechanical ventilation.
Methods: Using specific keywords, a comprehensive search of potential articles was carried out on PubMed, EMBASE, Scopus, and Cochrane databases with a time limit of 2013 to 2022. This study protocol was registered at PROSPERO (CRD42022336646) ) on August 7th, 2022.
Result: A total of 7 studies with 2,054 patients with mechanical ventilation met the criteria for this study and were included in a systematic review after a thorough database check. One study found no correlation between hemoglobin and the successful weaning and extubation process. Six studies stated that hemoglobin levels were associated with the success of the weaning and extubation process in critically ill patients with mechanical ventilation.
Conclusion: This study concludes that hemoglobin levels influence the weaning and extubation processes in critically ill patients with mechanical ventilation. However, more research is needed to confirm the results of this systematic review.

 File Digital: 1

Shelf
 SP-Slamet Agus Waluyo Jati.pdf :: Unduh

LOGIN required

 Metadata

No. Panggil : SP-pdf
Entri utama-Nama orang :
Entri tambahan-Nama orang :
Entri tambahan-Nama badan :
Subjek :
Penerbitan : Jakarta: Fakultas Kedokteran Universitas Indonesia, 2022
Program Studi :
Bahasa : ind
Sumber Pengatalogan : LibUI ind rda
Tipe Konten : text
Tipe Media : computer
Tipe Carrier : online resource
Deskripsi Fisik : xiii, 36 pages : illustration + appendix
Naskah Ringkas :
Lembaga Pemilik : Universitas Indonesia
Lokasi : Perpustakaan UI
  • Ketersediaan
  • Ulasan
No. Panggil No. Barkod Ketersediaan
SP-pdf 16-23-91709799 TERSEDIA
Ulasan:
Tidak ada ulasan pada koleksi ini: 9999920518329