Audit Penerapan Sistem Manajemen Keselamatan dan Kesehatan Kerja (K3) Listrik di Gedung Fasilitas Pelayanan Kesehatan = Audit of the Implementation of the Electrical Occupational Health and Safety (OH&S) Management System in the Healthcare Facility Building

Reza Andika Setyadi; Rudy Setiabudy, supervisor; Budi Sudiarto, examiner; Iwa Garniwa M.K., examiner; Chairul Hudaya, examiner (Fakultas Teknik Universitas Indonesia, 2023)

 Abstrak

Kecelakan kerja setiap tahun nya kerap kali meningkat, hal ini bisa disebabkan oleh banyak faktor dan didasarkan pada sistem manajemen keselamatan dan kesehatan kerja yang kurang baik. Pelaksanaan sistem manajemen Keselamatan dan Kesehatan Kerja (K3) adalah salah satu bentuk upaya untuk menciptakan tempat kerja yang aman dan sehat sehingga dapat mengurangi terjadinya risiko besar berupa kecelakaan, kebakaran, peledakan, dan penyakit akibat kerja. Bidang listrik sendiri menjadi sektor yang paling sering dan/atau memiliki tingkat keparahan terbesar dalam kasus kebakaran. Penelitian ini merupakan studi kasus audit penerapan SMK3 bidang listrik di salah satu fasilitas pelayanan kesehatan. Audit yang dilakukan terdiri dari audit dokumen (ISO 45001), visual (standar kelistrikan), dan pengukuran (kualitas daya, tahanan isolasi penghantar, dan instalasi penyalur petir) dengan metode studi kasus deskriptif. Penerapan SMK3 telah baik dengan tingkat kepatuhan 94.55% berdasarkan ISO 45001. Berdasarkan audit visual didapatkan titik risiko kebakaran tertinggi terdapat pada Panel Prelevement dan Ruang Genset. Sedangkan titik risiko kecelakaan kerja listrik tertinggi terdapat pada Panel Pit. Kedua temuan titik risiko tersebut berkaitan dengan temuan ISO 45001, yaitu perusahaan belum melaksanakan audit external dan audit internal. Disisi lain, ditemukan keberadaan harmonisa individual arus yang melampaui batas standar yang dibangkitkan oleh peralatan fasilitas pelayanan kesehatan. Tidak ditemukan masalah dari nilai karakteristik beban listrik. Sedangkan, Penghantar listrik dan instalasi penyalur petir sudah terpasang dan dalam kondisi baik.

Work-related injuries often increase every year, it could be due to many factors with a poor occupational health and safety management system. The implementation of an Occupational Safety and Health (OH&S) management system is one form of effort to create a safe and healthy workplace therefore to reduce the occurrence of major risks in the form of accidents, fires, explosions, and occupational diseases. The electricity itself is the sector that is most frequent and/or has the greatest degree of severity in fire cases. This research is a case study on the application of electrical OH&S audits in a health care facility. The audits carried out consisted of document audits (ISO 45001), visuals (electrical standards), and measurements (power quality, insulation resistance of cable, and lightning protection) using a descriptive case study method. The implementation of OH&S has been good with a compliance level of 94.55% based on ISO 45001. However, based on a visual audit, it was found that the highest fire risk were in the Prelevement Panel and Genset Room. Meanwhile, the highest risk point for electrical work accidents is in the Pit Panel. The two risk point findings are related to ISO 45001 findings, the company has not carried out external and internal audits. On the other hand, individual harmonic current generated by health care facility equipment were found exceeded the standard limits. No problems were found from the value of the electrical load characteristics. Meanwhile, the electrical conductor and lightning conductor installation have been installed and are in good condition.

 File Digital: 1

Shelf
 T-Reza Andika Setyadi.pdf :: Unduh

LOGIN required

 Metadata

No. Panggil : T-pdf
Entri utama-Nama orang :
Entri tambahan-Nama orang :
Entri tambahan-Nama badan :
Subjek :
Penerbitan : Jakarta: Fakultas Teknik Universitas Indonesia, 2023
Program Studi :
Bahasa : ind
Sumber Pengatalogan : LibUI ind rda
Tipe Konten : text
Tipe Media : computer
Tipe Carrier : online resource
Deskripsi Fisik : xiii, 88 pages : illustration + appendix
Naskah Ringkas :
Lembaga Pemilik : Universitas Indonesia
Lokasi : Perpustakaan UI
  • Ketersediaan
  • Ulasan
No. Panggil No. Barkod Ketersediaan
T-pdf 15-23-97068021 TERSEDIA
Ulasan:
Tidak ada ulasan pada koleksi ini: 9999920521175