:: UI - Skripsi Membership :: Kembali

UI - Skripsi Membership :: Kembali

Rancang Bangun Elektrokardiogram Lead Tunggal Portable Berbasis Bluetooth Dalam Mendeteksi Sinyal Simulator EKG SKX-2000+ = The Design of Single Lead Portable ECG with Bluetooth For ECG Simulator SKX-2000+ Signal Detection

Firda Fauziah; Tomy Abuzairi, supervisor; Siti Fauziyah Rahman, examiner; Taufiq Alif Kurniawan, examiner (Fakultas Teknik Universitas Indonesia, 2023)

 Abstrak

Elektrokardiogram (EKG) diketahui sebagai salah satu instrumen medis yang banyak digunakan sebagai alat diagnostik. Interpretasi dari sinyal EKG yang didapatkan akan membantu klinisi dalam memonitor kesehatan jantung pasien serta mendiagnosis kondisi-kondisi jantung tertentu yang dapat dilihat dari abnormalitas sinyal jantung yang terekam. Melalui penulisan ini, digagas sebuah inovasi EKG Lead Tunggal yang bersifat portable karena memanfaatkan pengiriman data serial sinyal EKG melalui koneksi Bluetooth ke perangkat laptop. Mikrokontroler ESP32-WROOM-32D dan modul detak jantung AD8232 digunakan dalam merancang purwarupa EKG Lead Tunggal ini. Hasil rangkaian keduanya kemudian diuji untuk melihat ketepatannya dalam mendeteksi sinyal jantung yang dihasilkan oleh simulator EKG SKX-2000+ untuk 7 komponen gelombang, yakni QRS Interval, QT/QTcB Interval, PR Interval, P Interval, R Amplitude, RR Interval, dan PP Interval. Dari 4 nilai delay yang digunakan dalam pengambilan data, yakni 2 ms, 20 ms, 25 ms, dan 30 ms, didapatkan bahwa delay 25 ms mampu memberikan hasil rata-rata error mutlak yang dapat diterima menurut standar LIPI ketika dibandingkan dengan nilai referensi manufaktur simulator untuk komponen QT/QTcB Interval, R Amplitude, RR Interval, dan PP Interval karena memiliki nilai error di bawah 5% dengan nilai persebaran data yang lebih kecil.

Electrocardiogram (ECG) is known as a medical instrument that is widely used as a diagnostic tool. Interpretation of the ECG signal obtained will assist the clinician in monitoring the patient's heart health and diagnosing certain heart conditions which can be seen from the abnormal heart signal recorded. Through this writing, a single lead ECG innovation was initiated which is portable because it utilizes sending ECG signal serial data via a Bluetooth connection to a laptop device. The ESP32-WROOM-32D microcontroller and the AD8232 heart rate module were used in designing this Single Lead ECG prototype. The results of both sets were then tested to see their accuracy in detecting heart signals generated by the SKX-2000+ ECG simulator for 7 wave components, namely the QRS Interval, QT/QTcB Interval, PR Interval, P Interval, R Amplitude, RR Interval, and PP Interval. Of the 4 delay values ​​used in data retrieval, which were 2 ms, 20 ms, 25 ms, and 30 ms, it was found that the 25 ms delay was able to provide acceptable average absolute error results according to LIPI standard when compared with the simulator manufacturing reference values ​​for the QT/QTcB Interval, R Amplitude, RR Interval, and PP Interval components because has an error value below 5% with a smaller data distribution value.

 File Digital: 1

Shelf
 S-Firda Fauziah.pdf :: Unduh

LOGIN required

 Metadata

No. Panggil : S-pdf
Entri utama-Nama orang :
Entri tambahan-Nama orang :
Entri tambahan-Nama badan :
Subjek :
Penerbitan : Depok: Fakultas Teknik Universitas Indonesia, 2023
Program Studi :
Bahasa : ind
Sumber Pengatalogan : LibUI ind rda
Tipe Konten : text
Tipe Media : computer
Tipe Carrier : online resource
Deskripsi Fisik : xvi, 49 pages ; illustration ; 28 cm + appendix
Naskah Ringkas :
Lembaga Pemilik : Universitas Indonesia
Lokasi :
  • Ketersediaan
  • Ulasan
No. Panggil No. Barkod Ketersediaan
S-pdf 14-24-36462867 TERSEDIA
Ulasan:
Tidak ada ulasan pada koleksi ini: 9999920526254