:: UI - Skripsi Membership :: Kembali

UI - Skripsi Membership :: Kembali

Formulasi Serbuk Inhalasi untuk Pembawa Karbon Bertanda Rhenium Pengganti Technetium-99m (99mTc) sebagai Alternatif Diagnosis Emboli Paru = Formulation of Inhalation Powder for Rhenium-Labelled Carbon Carrier as a Substitute for Technetium-99m (99mTc) in the Alternative Diagnosis of Pulmonary Embolism

Ferry; Kurnia Sari Setio Putri, supervisor; Miftakul Munir, supervisor; Sutriyo, examiner; Catur Jatmika, examiner; Hindun Wilda Risni, examiner (Fakultas Farmasi Universitas Indonesia, 2023)

 Abstrak

Emboli paru merupakan kondisi dimana gumpalan darah di dalam vena besar pada ekstremitas bawah masuk ke arteri pulmonal sehingga mengganggu aliran darah ke paru-paru. Metode ventilasi-perfusi SPECT/CT yang dikombinasikan dengan agen perunut seperti Technetium-99m (99mTc) dapat digunakan untuk mendiagnosis penyakit emboli paru. Karbon aktif dapat digunakan sebagai adsorben radioaktif 99mTc, namun sifat aerodinamisnya yang buruk menjadi tantangan untuk digunakan secara inhalasi. Kombinasi dengan serbuk pembawa inhalasi diharapkan dapat meningkatkan sifat aerodinamis karbon aktif bertanda 99mTc. Penelitian ini bertujuan untuk mengembangkan serbuk inhalasi karbon aktif bertanda 99mTc sehingga dapat diberikan secara inhalasi untuk diagnosis emboli paru. Serbuk pembawa inhalasi dibuat dengan memformulasikan manitol dengan 5–10% b/b leusin; 1,25–2,5% b/b amonium bikarbonat, atau kombinasi keduanya. Serbuk pembawa dibuat dengan metode semprot kering, kemudian dikarakterisasi morfologi, rendemen, kandungan lembab, densitas, ukuran partikel geometris, dan aerodinamis. Setelah itu, serbuk pembawa dengan karakteristik terbaik dicampurkan dengan serbuk karbon aktif bertanda Rhenium (placebo untuk 99mTc karbon) dengan perbandingan 1:1 dan 1:2, kemudian dikarakterisasi kembali. Serbuk pembawa manitol dengan 10% leusin dan 5% amonium bikarbonat (SP5) menunjukkan karakteristik terbaik dengan nilai MMAD, EF, FPF sebesar 6,95 ± 1,29 μm; 62,4 ± 7,92 %; 44,82 ± 9,31 % berturut-turut. Serbuk inhalasi karbon aktif bertanda Rhenium yang dicampur dengan serbuk pembawa 1:2 (F2) menunjukkan peningkatan sifat aerodinamis dan ukuran partikel, dengan nilai MMAD, EF, FPF sebesar 6,62 μm; 76,4%; dan 45,55% berturut-turut. Kombinasi karbon aktif bertanda Rhenium yang dicampur dengan serbuk pembawa 1:2 dianggap sesuai untuk serbuk inhalasi dan dapat dikembangkan lebih lanjut untuk diagnosis emboli paru.

Pulmonary embolism is a condition where blood clots in the major veins of the lower extremities enter the pulmonary artery, disrupting blood flow to the lungs. Ventilation-perfusion SPECT/CT method, combined with a tracer agent such as Technetium-99m (99m) can be used to diagnose pulmonary embolism. Activated carbon can be used as a radioactive adsorbent for 99mTc, but its poor aerodynamic properties pose a challenge for inhalation use. Combining it with carrier-based DPI is expected to improve the aerodynamic properties of 99mTc-labelled activated carbon. Therefore, this study aims to develop dry powder inhaler (DPI) of 99mTc-labelled activated carbon for the inhalation-based diagnosis of pulmonary embolism. Carrier-based DPI powders were prepared by formulating mannitol with 5–10% (w/w) leucine, 1,25–2,5% (w/w) ammonium bicarbonate, or a combination of both. The carrier-based DPI powders were produced using the spray-drying method and then characterized for morphology, yield, moisture content, density, geometric and aerodynamic particle size. Subsequently, the carrier-based DPI powder with the best characteristics was mixed with Rhenium-labelled activated carbon powder (placebo for 99m (Tc carbon) at ratios of 1:1 and 1:2, and characterized again. This study showed mannitol carrier-based DPI powder with 10% leucine and 5% ammonium bicarbonate (SP5) exhibited the best characteristics with MMAD, EF, FPF values of 6,95 ± 1,29 μm; 62,4 ± 7,92 %; 44,82 ± 9,31 % respectively. Rhenium-labelled activated carbon inhalable powder mixed with carrier-based DPI powder at a ratio of 1:2 (F2) showed improved aerodynamic properties and particle size, with MMAD, EF, FPF values of 6,62 μm; 76,4%; dan 45,55% respectively. Thus, the combination of Rhenium-labelled activated carbon mixed with carrier-based DPI powder at a ratio of 1:2 is considered suitable for inhalable powder and can be further developed for the diagnosis of pulmonary embolism.

 File Digital: 1

Shelf
 S-Ferry.pdf :: Unduh

LOGIN required

 Metadata

No. Panggil : S-pdf
Entri utama-Nama orang :
Entri tambahan-Nama orang :
Entri tambahan-Nama badan :
Subjek :
Penerbitan : Depok: Fakultas Farmasi Universitas Indonesia, 2023
Program Studi :
Bahasa : ind
Sumber Pengatalogan : LIbUI ind rda
Tipe Konten : text
Tipe Media : computer
Tipe Carrier : online resource
Deskripsi Fisik : xvi, 50 pages : illustration + appendix
Naskah Ringkas :
Lembaga Pemilik : Universitas Indonesia
Lokasi : Perpustakaan UI
  • Ketersediaan
  • Ulasan
No. Panggil No. Barkod Ketersediaan
S-pdf 14-24-84224593 TERSEDIA
Ulasan:
Tidak ada ulasan pada koleksi ini: 9999920528327