Deskripsi Lengkap

Sumber Pengatalogan : LibUI eng rda
ISSN : 20869614
Majalah/Jurnal : International Journal of Technology
Volume : Vol. 7, No. 5, July 2016: Hal. 921-927
Tipe Konten : text (rdacontent)
Tipe Media : unmediated (rdamedia)
Tipe Carrier : volume (rdacarrier)
Akses Elektronik : http://dx.doi.org/10.14716/ijtech.v7i5.1329
Institusi Pemilik : Universitas Indonesia
Lokasi : Perpustakaan UI, Lantai 4 R. Koleksi Jurnal
 
  •  Ketersediaan
  •  File Digital: 0
  •  Ulasan
  •  Sampul
  •  Abstrak
No. Panggil No. Barkod Ketersediaan
UI-IJTECH 7:5 (2016) 08-23-30797944 TERSEDIA
Tidak ada ulasan pada koleksi ini: 9999920529592
 Abstrak
The performance of a 20 MW gas turbine power plant was described by using the exergy analysis and data from the plant?s record books. The first and second laws of thermodynamics, as well as the mass and energy conservation law, were applied in each of the components. The results show that more exergy destruction occured in the combustion chamber up to 71.03% or 21.98 MW. Meanwhile, the lowest exergy occured in the compressor at 12.33% or 3.15 MW. Thermal efficiency of the gas turbine power plant, according to the first law, was 33.77%, and exergy efficiency was 32.25%.