:: UI - Skripsi Membership :: Kembali

UI - Skripsi Membership :: Kembali

Pengaruh Injeksi Udara Pada Elektrolisis Plasma Anodik Untuk Degradasi Limbah Fenol dan Cr(VI) Dengan Aditif Fe2+ = Effect of Air Injection on Anodic Plasma Electrolysis for Phenol and Cr(VI) Waste Degradation with Fe2+ Additives

Tamima Nurindra Prameswari; Nelson Saksono, supervisor; Sutrasno Kartohardjono, examiner; Yuliusman, examiner (Fakultas Teknik Universitas Indonesia, 2021)

 Abstrak

Fenol dan Cr(VI) merupakan salah satu limbah organik dan anorganik yang memiliki tingkat toksisitas yang tinggi dikarenakan sifatnya yang beracun sehingga dapat menimbulkan efek buruk bagi kesehatan manusia dan lingkungan. Untuk itu diperlukan sebuah pengolahan limbah simultan yang dapat mendegradasi limbah agar dapat aman jika diteruskan ke lingkungan. Teknologi untuk mengolah kembali limbah tersebut ialah teknologi elektrolisis plasma. Pengujian dengan kondisi optimum diperlukan agar dapat mengetahui kondisi yang optimal dalam mendegradasi limbah Fenol dan Cr(VI). Dengan menguji konsentrasi awal limbah fenol, penambahan aditif Fe2+ dan adanya injeksi udara. Degradasi limbah berhasil terukur dengan alat Spektrofotometer UV-VIS dengan kondisi optimum limbah awal Fenol 400 ppm, limbah awal Cr(VI) 100 ppm, konsentrasi Fe2+ 30 ppm, injeksi udara 0.4 L/min, Na2SO4 0.01 M pada tegangan 650 V selama 120 menit menghasilkan persentase degradasi limbah fenol sebesar 61,7% dan limbah Cr(VI) sebesar 97%. Nilai mmol terdegradasi untuk limbah fenol sebesar 1,639 mmol dan limbah Cr(VI) sebesar 0,961 mmol. Serta konsumsi energi 3467,88 kJ dan energi spesifik 1333,80 kJ/mmol.

Phenol and Cr(VI) are one of the organic and inorganic wastes that have a high level of toxicity due to their toxic nature so that they can cause adverse effects on human health and the environment. For this reason, a simultaneous waste treatment is needed that can degrade waste so that it can be safely forwarded to the environment. The technology for reprocessing the waste is plasma electrolysis technology. Testing with optimum conditions is needed in order to determine the optimal conditions in degrading Phenol and Cr(VI) waste. By testing the initial concentration of phenol waste, the addition of Fe2+ additives and the presence of air injection. Waste degradation was successfully measured using a UV-VIS Spectrophotometer with optimum conditions for initial waste Phenol 400 ppm, initial waste Cr(VI) 100 ppm, Fe2+ concentration 30 ppm, air injection 0.4 L/min, Na2SO4 0.01 M at a voltage of 650 V for 120 minutes resulted in the percentage of phenol waste degradation of 61.7% and Cr(VI) waste of 97%. The degraded mmol value for phenol waste is 1.639 mmol and Cr(VI) waste is 0.961 mmol. And energy consumption is 3467.88 kJ and specific energy is 1333.80 kJ/mmol

 File Digital: 1

Shelf
 S-Tamima Nurindra Prameswari.pdf :: Unduh

LOGIN required

 Metadata

No. Panggil : S-pdf
Entri utama-Nama orang :
Entri tambahan-Nama orang :
Entri tambahan-Nama badan :
Subjek :
Penerbitan : Depok: Fakultas Teknik Universitas Indonesia, 2021
Program Studi :
Bahasa : ind
Sumber Pengatalogan : LibUI ind rda
Tipe Konten : text
Tipe Media : computer
Tipe Carrier : online resource
Deskripsi Fisik : xiv, 65 pages : illustration + appendix
Naskah Ringkas :
Lembaga Pemilik : Universitas Indonesia
Lokasi : Perpustakaan UI
  • Ketersediaan
  • Ulasan
No. Panggil No. Barkod Ketersediaan
S-pdf 14-23-46366018 TERSEDIA
Ulasan:
Tidak ada ulasan pada koleksi ini: 9999920533544