:: UI - Skripsi Membership :: Kembali

UI - Skripsi Membership :: Kembali

STUDI KUAT TARIK BETON NORMAL MUTU RENDAH DENGAN CAMPURAN ABU SEKAM PADI (RHA) DAN LIMBAH ADUKAN BETON (CSW) = The Study on Tensile Strength of Normal Concrete Containing Rice Husk Ash (RHA) and Concrete Sludge Waste (CSW) Designed for Low Strength

Andi Muhammad Wahid Bukhari; Essy Arijoeni Basoenondo, supervisor; Madsuri, supervisor; Setyo Supriyadi Sipadi, examiner (Fakultas Teknik Universitas Indonesia, 2013)

 Abstrak

Skripsi ini membahas tentang penggunaan Abu Sekam Padi (RHA) sebagai bahan subtitusi perekat semen dan penggunaan Limbah Adukan Beton (CSW) sebagai agregat halus untuk mengurangi penggunaan jumlah pasir pada beton. Penelitian dilakukan dengan membuat mix design dari beton normal fc’ 25 MPa dan dikembangkan pada lima variasi campuran dengan jumlah CSW 30%, 40%, 50%, 60% dan 70% dengan penggunaan RHA tetap yaitu 8% dari total pemakaian semen. Sifat mekanis beton yang diuji meliputi: kuat tarik lentur, kuat tarik belah, kuat geser dan susut. Pengujian dilakukan pada umur 28, 56 dan 90 hari terhadap lima benda uji pada setiap umur pengujian. Pada pengujian kuat tarik lentur, kuat tarik belah dan kuat geser nilai optimum terjadi pada campuran dengan jumlah CSW 30%, sedangkan prosentase susut terbesar terjadi pada beton dengan campuran CSW 70%. Dari penelitian ini diharapkan beton dengan campuran RHA dan CSW dapat diaplikasikan untuk perkerasan jalan

The focus of the study is observing the use of Rice Husk Ash (RHA) as a subtitute of portland cement and Concrete Sludge Waste (CSW) to reduce of sand in concrete. Refers to the mix design of normal concrete fc’ 25 MPa the mechanical properties tested in five variations with a percentage of CSW 30%, 40%, 50%, 60%, 70% and using fixed number 8% of RHA. The concrete were tested in flexural tensile strength, split tensile strength, shear strength and shrinkage at the age of 28,56 and 90 days for five specimens at each age of test. From the testing of flexural tensile strength, split tensile strength and shear strength obtained an optimum number of CSW 30%. And the largest percentage of shrinkage occurred in CSW 70%. From the result has been obtained, the concrete with RHA and CSW could be applied to the road pavement.

 File Digital: 1

Shelf
 S-Andi Muhammad Wahid Bukhari.pdf :: Unduh

LOGIN required

 Metadata

No. Panggil : S-pdf
Entri utama-Nama orang :
Entri tambahan-Nama orang :
Entri tambahan-Nama badan :
Subjek :
Penerbitan : Depok: Fakultas Teknik Universitas Indonesia, 2013
Program Studi :
Bahasa : ind
Sumber Pengatalogan : LibUI ind rda
Tipe Konten : text
Tipe Media : computer
Tipe Carrier : online resource
Deskripsi Fisik : xii, 117 pages : illustration + appendix
Naskah Ringkas :
Lembaga Pemilik : Universitas Indonesia
Lokasi : Perpustakaan UI
  • Ketersediaan
  • Ulasan
No. Panggil No. Barkod Ketersediaan
S-pdf 14-23-72503149 TERSEDIA
Ulasan: