:: UI - Tugas Akhir :: Kembali

UI - Tugas Akhir :: Kembali

Akurasi pencetakan rahang tidak bergigi untuk gigi tiruan lengkap dukungan implan menggunakan teknik digital dan konvensional: Sebuah tinjauan sistematik = Accuracy of digital and conventional impressions technique for implant supported complete denture: A systematic review

Dwi Hardhini; Nina Ariani, supervisor; M.F. Lindawati S. Kusdhany, supervisor; Ira Tanti, examiner; Muslita Indrasari, examiner; R.M. Tri Ardi Mahendra, examiner (Fakultas Kedokteran Gigi Universitas Indonesia, 2024)

 Abstrak

Latar belakang: Akurasi hasil pencetakan merupakan hal penting dalam pembuatan gigi tiruan terutama pada gigi tiruan lengkap dukungan implan. Tinjauan sistematik ini disusun untuk membandingkan akurasi hasil pencetakan digital menggunakan pemindai intra oral dibandingkan dengan pencetakan konvensional.
Metode: Tinjauan sistematik ini disusun berdasarkan literatur penelitian klinis berdasarkan Preferred Reporting Items for Systematic Review and Meta Analysis (PRISMA) dan teregistrasi pada PROSPERO dengan nomor CRD42023478021. Terdapat empat database dan sistem pencarian manual yang digunakan dalam periode 2008-2023. Literatur yang dievaluasi merupakan penelitian yang membahas tentang akurasi hasil pencetakan gigi tiruan dukungan implan secara digital dan konvensional yang dilakukan pada kasus dengan minimal empat implan terpasang pada rahang yang telah kehilangan seluruh gigi. Penilaian risiko bias dilakukan dengan menggunakan Cochrane RoB-2 dan ROBINS-I.
Hasil: Total 368 literatur diperoleh dari empat database dan 297 literatur diseleksi berdasarkan judul dan abstrak setelah eliminasi duplikat. Total tujuh literatur dari database memenuhi kritera inklusi dan digabungkan dengan satu literatur hasil pencarian manual. Delapan literatur dilakukan analisis. Akurasi hasil pencetakan secara tiga dimensi memiliki nilai yang bervariasi namun masih dalam rentang yang dapat diterima secara klinis (200μm). Gigi tiruan yang dihasilkan juga memiliki passive fit yang baik. Secara radiografis, mayoritas gigi tiruan yang dihasilkan tidak memiliki celah di antara superstruktur dengan implan. Hasil analisis Grading of Recommendation Assessment Development and Evaluation (GRADE) seluruh kualitas literatur yang diperoleh memiliki kualitas yang tergolong tinggi. Kesimpulan: Berdasarkan hasil analisis tersebut, hasil pencetakan digital memiliki keakurasian yang setara dengan pencetakan konvensional dalam aplikasi klinis.

Background: Accuracy of the impression is important in making dentures, especially in implant-supported complete dentures. This systematic review conducted to compare accuracy of digital impressions using intra-oral scanners and conventional impressions.
Method: This systematic review followed the Preferred Reporting Items for Systematic Review and Meta Analysis (PRISMA) and registered on PROSPERO with number CRD42023478021. Four databases and a manual search system limited to publication date 2008-2023 period. Literature evaluated based on data discusses accuracy of digital and conventional implant-supported denture impressions carried out in cases with minimum four implant on fully edentulous jaw. Risk of bias assessment was performed using the Cochrane RoB-2 and ROBINS-I.
Result: A total of 368 literature was obtained from four databases and 297 literature was selected based on title and abstract after duplicate removal. A total of seven literature from the database met the inclusion criteria and was combined with one literature resulting from a manual search. Eight literature were analyzed. Three- dimensional accuracy of impressions varies but is still within the clinically acceptable range (200μm). Dentures from all impressions also has a good passive fit. Radiographically, the majority of dentures produced do not have voids between the superstructure and the implant. Quality assessment with Grading of Recommendation Assessment Development and Evaluation (GRADE) shows high level of quality evidence for all literature.
Conclusion: Based on the results of this analysis, conventional and digital impressions results have comparable accuracy in clinical applications.

 File Digital: 1

Shelf
 SP-Dwi Hardhini.pdf :: Unduh

LOGIN required

 Metadata

No. Panggil : SP-pdf
Entri utama-Nama orang :
Entri tambahan-Nama orang :
Entri tambahan-Nama badan :
Subjek :
Penerbitan : Jakarta: Fakultas Kedokteran Gigi Universitas Indonesia, 2024
Program Studi :
Bahasa : ind
Sumber Pengatalogan : LibUI ind rda
Tipe Konten : text
Tipe Media : unmediated ; computer
Tipe Carrier : volume ; online resource
Deskripsi Fisik : xiv, 56 pages : illustrations ; 28 cm. + appendix
Naskah Ringkas :
Lembaga Pemilik : Universitas Indonesia
Lokasi : Perpustakaan UI, Lantai 3
  • Ketersediaan
  • Ulasan
No. Panggil No. Barkod Ketersediaan
SP-pdf 16-24-93996405 TERSEDIA
Ulasan:
Tidak ada ulasan pada koleksi ini: 9999920541636