Ditemukan 18 dokumen yang sesuai dengan query
Hidjan, author
ABSTRAK
Tujuan dari eksperimen yang dilakukan adalah untuk menyelidiki hal-hal yang berkaitan dengan pembentukan plasma, yakni zat yang tersusun dari muatan-muatan listrik bebas berupa ion-ion positif dan elektron elektron negatif yang jumlahnya nyaris sama.
Plasma yang digunakan dalam eksperimen terbentuk dari udara laboratorium yang di iradiasi dengan berkas laser energi tinggi (...
Depok: Fakultas Teknik Universitas Indonesia, 1994
T-Pdf
UI - Tesis Membership Universitas Indonesia Library
Suroso, author
ABSTRACT
As transmission medium in optical communication system, optical fiber is also characterized by elastic properties beside of transmission properties of optical fiber. The Young Modulus of Elasticity of optical fiber could be measured by considering a bare optical fiber as cantilever which resonant with an acoustical vibration. To...
1992
T-Pdf
UI - Tesis Membership Universitas Indonesia Library
Samuel H. Tirtamihardja, author
ABSTRACT
Data acquisition system using diode array for a spectrometer has been designed and constructed. The light detection is performed by a photodiode array consisting of 512 photodiodes. The superior quantum efficiency of the detector and the direct increase of optical flux with photodiode electrons make it works as a very...
1989
T-Pdf
UI - Tesis Membership Universitas Indonesia Library
Marpaung, Mangasi Alion, author
ABSTRAK
An N2 laser system that consists of transversely excited atmospheric (TEA) oscillator and transversely excited (TE) amplifier has been designed and constructed. The laser system employs single common spark gap for both oscillator and amplifier. The optimum operating voltage is 15 kV at 2 Hz repetition rate. The measured energy...
1993
T-Pdf
UI - Tesis Membership Universitas Indonesia Library
Wahyu Setia Budi, author
ABSTRAK
A compact, simple and low-cost transversely excited atmospheric (TEA) pressure ultraviolet nitrogen laser {337 nm) has been designed and constructed employing the conventional Blumlein circuit. The measured energy of the output pulse of 337 nm is around 80 -J at 25 kV of charging voltage and l atm operating gas...
1992
T-Pdf
UI - Tesis Membership Universitas Indonesia Library
Dede Sujadi, author
Computer simulation program has been developed on the basis of Liapunov approach for the study of MRAC technique applied to pressure control for a vacuum system. Both proportional and integral feedback as well as disturbance feedforward is considered in the closed-loop system. The simulation result obtained with a personal computer...
Depok: Universitas Indonesia, 1989
T-Pdf
UI - Tesis Membership Universitas Indonesia Library
Sunarto, author
A fluorescence spectrometer, with gating PMT (Photo Multiplier Tube) has been designed and constructed for the observation of Time Resolved Spectroscopy. Employed as a source far the fluorescence spectrometer a pulsed N2 lasers with about 5-nanosecond pulse width and 400-kilowatt power. Gating PMT carries out the sampling. In this method...
Depok: Fakultas Teknik Universitas Indonesia, 1988
T-Pdf
UI - Tesis Membership Universitas Indonesia Library
M. Yunil, author
ABSTRACT
A vacuum chamber has been designed and constructed for the observation the primary plasma and secondary plasma which is generated by the bombardments of brass by N2 Laser beam with about 5 ns pulse width and 1 1W power.
The Radius and spectral emission of the resulting secondary plasma...
1988
T-Pdf
UI - Tesis Membership Universitas Indonesia Library
Lantu, author
ABSTRAK
The design and construction of eight-bit tune delay autocorrelator is discussed, suitable for use in photon correlation experiments. The sampling time of the correlator can be varied from 1 usec to 100/usec, devide into a number ( typically 256 ) channels (time interval). The instruments records the number of pulses...
1987
T-Pdf
UI - Tesis Membership Universitas Indonesia Library
Ering Poernomo Setianto, author
ABSTRACT
The principles of frequency stabilization is to keep constant the optical path length in laser cavity by controlling the laser- tube length. In this system used temperature servo control to control the laser tube length.
As reference to an error derived by a sensitive frequency discriminator. Basically the operation of this...
Depok: Fakultas Teknik Universitas Indonesia, 1988
T-Pdf
UI - Tesis Membership Universitas Indonesia Library