Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 166084 dokumen yang sesuai dengan query
cover
Feni Triana Zulfia
"Lapisan tipis imobilisasi sel khamir Candida fukuyamaensis UICC-Y247 telah dibuat sebagai modifikasi transduser pada permukaan elektroda sensor oksigen GC-NPAu untuk metode alternatif sensor BOD (Biochemical Oksigen Demand). Lapisan dibuat menggunakan matriks agarose/KCl sebagai biomembran dengan teknik evaporasi, kemudian aktifitasnya didukung dengan adanya tambahan membran Nafion 50 mikron. Sistem sensor ini mempersingkat waktu pengukuran BOD dari 5 hari menjadi 30 menit. Aktivitasnya dibandingkan dengan menggunakan keadaan sel bebas dan terimobilisasi. Deteksi nilai BOD dilakukan dengan menggunakan teknik Multi Pulse Amperometry (MPA) pada potensial 450 mV. Keberhasilan sistem terlihat adanya peningkatan arus dari plot linieritas sistem terhadap larutan uji glukosa dari konsentrasi 0,1 mM sampai 0,5 mM setara dengan nilai BOD (10 mg/L sampai 50 mg/L). Optimalisasi pengukuran BOD dihasilkan waktu optimum BOD sebesar 30 menit, dengan menggunakan sel khamir yang telah diinkubasi selama 30 jam. Scan rate optimum 100 mV/s, dengan memvariasikan ketebalan membran Nafion, 0,25 mL sampai 1 mL campuran imobilisasi, hasil ketebalan optimum adalah 1 mL campuran imobilisasi. Batas deteksi larutan glukosa pada sistem sensor adalah 0,011336 mM atau nilai BOD sebesar 1,1336 mg/L. Pengukuran respon arus terhadap larutan glukosa dilakukan pengulangan sebanyak 15 kali, didapatkan nilai standar deviasi relatif 4,776% untuk elektroda tanpa kehadiran sel khamir dan 2,702% untuk elektroda yang telah dilekatkan dengan lapisan imobilisasi. Hasil pengujian kestabilan, ditemukan bahwa lapisan imobilisasi stabil selama 1-3 hari."
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2010
S30708
UI - Skripsi Open  Universitas Indonesia Library
cover
Nathanael, Dante
"Pengembangan sensor BOD dilakukan dengan elektroda glassy carbon terdeposisi partikel emas dan terimobilisasi lapisan tipis khamir Candida fukuyamaensis UICCY-247. Proses modifikasi glassy carbon dengan partikel emas dilakukan dengan proses elektrodeposisi pada potensial -300mV dengan menggunakan Multi Pulse Amperometry (MPA) terhadap Ag/AgCl. Karakterisasi dengan SEM menunjukkan ukuran partikel emas yang melapisi glassy carbon adalah sekitar 66 nm. Proses imobilisasi mikroba khamir dilakukan dengan matriks Agarose/KCl 2% yang diratakan pada permukaan membran Nafion®. Deteksi nilai oksigen yang digunakan oleh mikroorganisme dilakukan dengan teknik MPA pada potensial -600mV. Hasil pengukuran kalibrasi linier pada keadaan free cell dan keadaan terimobilisasi lapisan tipis khamir menunjukan nilai daerah kelinieran yang baik dengan nilai regresi R2 = 0,93 untuk keadaan free cell dan R2 = 0,933 untuk keadaan terimobilisasi lapisan tipis khamir. Pengukuran terhadap kestabilan lapisan tipis menunjukan bahwa pada setiap hari pengukuran, terjadi penurunan arus reduksi yang terukur sebagai akibat semakin sedikitnya jumlah sel khamir yang hidup dalam sistem. Presisi pengukuran dengan elektroda GC-Au pada 15 kali pengukuran dengan cyclic voltametry memberikan nilai RSD 18,49% untuk keadaan tanpa kehadiran sel khamir dan RSD 14,65% dalam keadaan terimobilisasi lapisan tipis sel khamir. Pengaruh kehadiran logam berat pada sistem pengukuran dilakukan dengan memvariasikan konsentrasi spesi Cu. Pengukuran dengan MPA pada -600mV terhadap Ag/AgCl menunjukan kenaikan arus reduksi terhadap kenaikan konsentrasi spesi Cu karena makin sedikit jumlah oksigen yang dapat digunakan oleh mikroorganisme akibat jumlah mikroorganisme efektif dalam sistem akan semakin sedikit. Uji kesetaraan yang dilakukan antara metode sensor BOD dan BOD konvensional menghasilkan perbandingan yang cukup baik sehingga dapat disimpulkan metode sensor BOD memiliki keakuratan pengukuran yang cukup baik.

The development of BOD sensor conducted with glassy carbon gold particles deposited electrode and immobilized with a thin layer of yeast Candida fukuyamaensis UICCY-247. The process of glassy carbon modification with gold particles carried by the process of electrodeposition at a potential 300mV by using Multi-Pulse Amperometry (MPA) against Ag / AgCl. Characterization by SEM shows the size of gold particles lining the glassy carbon is about 66 nm. The process of microbial immobilization of yeast is done by using matrix agarose / KCl 2%, which flattened at the surface of Nafion ® membrane. Detection of oxygen used by microorganisms was done by using MPA on the potential-600mV. Linear calibration measurement results on the state of free cell and immobilized state of a thin layer of yeast showed good linearity local value with the value of regression R2 = 0.93 for the state of free cell and R2 = 0.933 for the immobilized state of a thin layer of yeast. Measurements showed that the stability of a thin layer on each day of measurement, there was a measurable decrease in flow reduction as a result of the small number of yeast cells that live within the system. Precision measurement with GC-Au electrode in 15 times of measurement by cyclic voltametry 18.49% RSD value for the state without the presence of yeast cells and 14.65% RSD in the immobilized state of a thin layer of yeast cells. Effect of the presence of heavy metals on the measurement system is done by varying the concentration of Cu species. Measurements with MPA at-600mV against Ag / AgCl showed increased flow reduction of Cu species concentration increases because the less amount of oxygen that can be used by microorganisms due to the number of effective microorganisms in the system will be less. Equivalence test conducted between the sensor BOD and BOD methods of conventional produce a pretty good ratio so it can be concluded, BOD sensor has a good accuracy on measurement."
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2011
S360
UI - Skripsi Open  Universitas Indonesia Library
cover
Faiza Maryani
"Sensitivitas elektroda emas dan elektroda glassy carbon sebagai sensor oksigen dapat ditingkatkan melalui modifikasi nanopartikel emas pada permukaan elektroda glassy carbon. Modifikasi ini dapat dilakukan dengan menggunakan teknik self assembly. Deteksi oksigen dengan elektroda termodifikasi ini dapat digunakan untuk pengukuran nilai BOD. Sensor pengukuran BOD dianalisakan sebagai sensor oksigen terlarut dalam air dengan memperhitungkan selisih dari kadar oksigen yang terlarut sebelum dikonsumsi oleh mikroorganisme, dan setelah dikonsumsi oleh mikroorganisme.
Pengukuran sensor oksigen ini dilakukan dengan menggunakan cyclic voltammetry pada kisaran potensial -2000 mV hingga 2000 mV dan scanrate 100 mV/s. Puncak reduksi untuk pengukuran oksigen dengan menggunakan elektroda GC-NP Au berada pada potensial sekitar -0,538 V, sedangkan untuk elektroda GC dan Au masing-masing berada pada potensial -0,51 V dan -1,16 V.
Hasil pengukuran menunjukkan bahwa kemampuan pemisahan sinyal dari background pada elektroda GC-NP Au (S/B=1,8994) lebih baik dibandingkan pada elektroda GC (S/B=1,53) dan elektroda Au (S/B=1,19). Elektroda GC-NP Au sensitivitas yang lebih baik dibanding GC dan Au. Presisi pengukuran respon arus sebanyak 10 kali terhadap larutan buffer posfat yang dialiri oksigen selama dua menit diperoleh sebesar 19,44% (RSD) untuk Au, 11,84% untuk GC, dan 10,50% untuk GC-NP Au. Hasil pengujian elektroda GC-NP Au untuk pengukuran BOD menunjukkan perbedaan arus yang sangat signifikan pada saat adanya khamir dan saat tidak adanya khamir.

Sensitivity of gold electrodes and glassy carbon electrodes as oxygen sensors can be improved through modification of gold nanoparticles on glassy carbon electrode surface. This modification can be done using self assembly techniques. Detection of oxygen with this modified electrode can be used for the measurement of BOD value. Sensors that is used for the measurement of BOD value is sensor for measurement of dissolved oxygen in water by calculating the difference in the levels of dissolved oxygen before being consumed by microorganisms, and when consumed by microorganisms.
Measurement of the oxygen sensor is performed using cyclic voltammetry at potential range of -2000 mV to 2000 mV and scanrate 100 mV/s. Reduction peak for oxygen measurement using GC-NP Au electrode at a potential of about -0.538 V, whereas for GC and Au electrodes each are at potential -0.51 V and -1.16 V.
The measurement results show that the separation ability of the background signal on GC electrode Au-NP (S / B = 1.8994) better than the GC electrode (S / B = 1.53) and Au electrodes (S / B = 1.19). Sensitivity of GC-NP Au electrode is better than GC and Au. Precision measurement of the flow response to the phosphate buffer solution by flowing oxygen for two minutes was obtained for 19.44% (RSD) for Au, 11,84% for GC, and 10,50% for GC-NP Au. Test results-NP Au GC electrode for BOD measurement showed a highly significant difference in flow at the moment the absence of yeast and the present of yeast.
"
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2010
S54634
UI - Skripsi Open  Universitas Indonesia Library
cover
Harmesa
"Pengaruh ion Cu2+ diuji untuk sensor BOD yang sedang dikembangkan. Sensor BOD dibuat dengan menggunakan sistem sel khamir bebas untuk khamir Rhodotorula mucilaginosa UICC Y-181 dan khamir Candida fukuyamaensis UICC Y-247 pada elektroda emas. Penentuan nilai reduksi oksigen pada -600 mV (vs Ag/AgCl) ditentukan dengan cyclic voltametri. Sedangkan deteksi oksigen sisa yang tidak digunakan oleh mikroorganisme dilakukan dengan teknik multi pulse amperometry (MPA). Hasil pengukuran kalibrasi linier pada keadaan free cell untuk kedua jenis khamir menunjukkan nilai daerah kelinieran yang baik dengan nilai regresi 0,994 dan 0,987 berturut-turut untuk keadaan free cell Rhodotorula mucilaginosa UICC Y-181 dengan waktu optimum pengukuran 20 menit dan untuk keadaan free cell Candida fukuyamaensis UICC Y-247 dengan waktu optimum pengukuran 25 menit. Presisi yang lebih baik ditunjukkan dengan 15 kali pengukuran untuk khamir Rhodotorula mucilaginosa dengan nilai RSD 0,9 %, sedangkan untuk khamir Candida fukuyamaensis dengan nilai RSD 5,01%. Pengaruh keberadaan logam berat pada sistem pengukuran dilakukan dengan menvariasikan konsentrasi ion Cu2+. Sensor BOD dengan Rhodotorula mucilaginosa menunjukkan ketahanan yang lebih baik terhadap kehadiran ion Cu2+ seperti ditunjukkan oleh sedikitnya kenaikan arus oksigen dibandingkan dengan kenaikan arus oksigen pada sensor BOD dengan Candida fukuyamaensis.

Influence of copper ions was examined on developed microbial BOD sensors.The BOD sensors carried out in a system consisted of free cell yeast and gold electrode. Rhodotorula mucilaginosa UICC Y-181 and Candida fukuyamaensis UICC Y-247 were used as the microbial yeasts. Oxygen reduction potensial of -600 mV (vs Ag/AgCl) was determined by using cyclic voltametry, whereas the excess oxygen concentration, which not used by microorganism, was determined by multy pulse amperometry (MPA). Optimum waiting times of 20 and 25 min were obtained for BOD sensors of Rhodotorula mucilaginosa UICC Y-181 and Candida fukuyamaensis UICC Y-247, respectively. Linear calibration curves showed good linearity with linear regressions of 0.994 and 0.987 for those of Rhodotorula mucilaginosa UICC Y-181 and Candida fukuyamaensis UICC Y-247, respectively. However, better precision of measurement (n=15) was shown by an RSD of 0.90% for Rhodotorula mucilaginosa, whereas it was 5.01% for Candida fukuyamaensis. Influence of copper ions was examined in various concentrations of Cu ions. BOD sensor of Rhodotorula mucilaginosa shows better resistance against Cu ions than that of Candida fukuyamaensis, as it is shown by less increasing of oxygen current at Rhodotorula mucilaginosa than that at Candida fukuyamaensis."
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2012
S1229
UI - Skripsi Open  Universitas Indonesia Library
cover
Aliyah
"Penelitian ini melakukan pengembangan sistem microbial fuel cell (MFC) dengan menggunakan elektroda busa karbon termodifikasi AuNP dan terfungsionalisasi mercapto benzoic acid (MBA). Elektroda busa karbon termodifikasi AuNP berhasil disintesis melalui metode hidrotermal. Hasil ini dikonfirmasi oleh analisis UV-Visible Spectrometer (UV-Vis), X-Ray Diffraction (XRD), Fourier Transform Infrared Spectroscopy (FTIR) dan Scanning Electron Microscope (SEM). Hasil analisis menggunakan Particle Size Analyzer (PSA) menunjukkan ukuran AuNP yang didapat yaitu sekitar 50 nm dengan distribusi yang bersifat polydisperse dan memiliki bentuk nanopartikel sphere yang dikonfirmasi melalui Transmission Electron Microscopy (TEM). Studi awal elektrokimia dengan metode Cyclic Voltammetry (CV) dengan rentang potensial -1,5 sampai 1,8 dengan scan rate 10 mV/s dilakukan untuk mengkonfirmasi bahwa elektroda busa karbon termodifikasi memiliki sifat elektro aktif terhadap glukosa, yang merupakan substrat atau bahan bakar pada sistem MFC ini. Kinerja MFC dievaluasi dengan menggunakan kurva polarisasi dan didapatkan hasil bahwa elektroda busa karbon termodifikasi AuNP terfungsionalisasi MBA memiliki nilai densitas arus dan daya yang lebih tinggi yaitu 1226, 93 mA/m2 dan 223,91 mW/m2 dibandingkan dengan elektroda tanpa fungsionalisasi yaitu  392,29 mA/ m2 dan 109,14 mW/ m2. Selain itu, studi Electrochemical Impedance Spectroscopy (EIS) dilakukan untuk mengetahui besarnya hambatan pada sistem MFC sehingga peyimpangan produksi daya dapat diketahui. 

This study developed a microbial fuel cell (MFC) system using carbon foam electrodes modified with AuNP and mercapto benzoic acid (MBA) functionalization. AuNP modified carbon foam electrodes were successfully synthesized by hydrothermal method. These results were confirmed by analysis of UV-Vis, XRD, FTIR, and SEM. The results of the analysis using the Particle Size Analyzer (PSA) show that the AuNP size obtained is around 50 nm with a polydisperse distribution and has a sphere nanoparticle shape confirmed by TEM. Initial electrochemical studies were conducted with the Cyclic Voltammetry (CV) method with a potential range of -1.5 to 1.8 and a scan rate of 10 mV/s were carried out to confirm that the modified carbon foam electrodes have electro-active properties against glucose, the substrate or fuel in this MFC system. MFC performance was evaluated using polarization curves and the results showed that the MBA functionalized AuNP modified carbon foam electrode had higher current density and power values, 1226, 93 mA/m2 and 223.91 mW/m2 compared to the electrode without functionalization, namely 392.29. mA/m2 and 109.14 mW/m2. In addition, an Electrochemical Impedance Spectroscopy (EIS) study was conducted to determine the amount of resistance in the MFC system so that deviations in power production could be identified."
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2020
T-pdf
UI - Tesis Membership  Universitas Indonesia Library
cover
Habibah Wardah
"Pengembangan sensor BOD (Biochemical Oksigen Demand) dilakukan menggunakan biosensing khamir Rhodotorula mucilaginosa UICC Y-181 yang terimobilisasi dalam matriks gelatin dan alginat. BOD diukur sebagai jumlah oksigen yang digunakan oleh biosensing dalam selang waktu tertentu untuk mengoksidasi senyawa organik dalam larutan. Pada penelitian ini glukosa digunakan sebagai model senyawa organik. Kadar oksigen dalam larutan diukur menggunakan elektroda emas dan elektoda Boron-Doped Diamond termodifikasi nanopartikel emas sebagai elektroda kerja dengan teknik Multi Pulse Amperometry melalui reaksi reduksi oksigen pada -554 mV (vs Ag/AgCl).
Kurva kalibrasi linear diperoleh dari perubahan arus reduksi oksigen setelah selang waktu tunggu optimum 20 menit (ΔI = I0 ?I20) pada larutan glukosa dalam berbagai variasi konsentrasi (0,1 ? 0,9 mM) setelah larutan dijenuhkan dengan oksigen. Selain mikroorganisme terimobilisasi, mikroorganisme dalam keadaan bebas (free cell) juga digunakan sebagai pembanding. Regresi linier (R2 = 0,95 - 0,99) dapat diperoleh pada semua sensor BOD baik dengan mikroorganisme bebas maupun terimobilisasi. Tetapi sensitivitas sensor dengan mikroorganisme bebas umumnya lebih tinggi daripada keadaan terimobilisasi, walaupun kedapatulangan yang lebih baik umumnya diperoleh pada sensor dengan mikroorganisme terimobilisasi, terutama yang terimobilisasi dalam matriks gelatin.

The development of BOD sensor was conducted by using Rhodotorula mucilaginosa UICC Y-181 yeast imobilized in gelatine and alginate matrix as the biosensing agent. BOD was measured as oxygen amount used by the biosensing agent to oxidize organic compounds in solution. In this work, glucose was used as an organic compound model. Oxygen concentration in water was measured by using gold and gold nanoparticles-modified Boron-Doped Diamond electrodes with Multy Pulse Amperometry technique via oxygen reduction reaction at -554 mV (vs Ag/AgCl).
Linear calibration curves was performed at change of oxygen reduction current after an optimum waiting time of 20 min ΔI (I0 ?I20) to solutions with a various glucose concentrations (0.1 - 0.9 mM) after saturated by oxygen. Beside the use of immobilized microorganism, free cell of the microorganism was also used as a comparison. The linear regression (R2 = 0.95 ? 0.99) could be observed at all BOD sensors with the free and the immobilized cells. However, the sensitivity of the sensors with free cell were generally higher than that of the immobilized ones, although better reproducibility was shown at the sensors with immobilized microorganisms, especially which were immobilized in gelatine matrix.
"
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2012
T31484
UI - Tesis Open  Universitas Indonesia Library
cover
Frandi Yuanda
"Konsumsi air yang bersih dan sehat adalah kebutuhan setiap mahluk hidup. Menurut WHO, konsentrasi ion kromium VI yang lebih dari 50 ppb dalam air minum dapat membahayakan kesehatan manusia WHO 1993 . Untuk itu perlu suatu metode penentuan konsentrasi ion kromium VI dalam suatu sampel dengan mudah, murah, cepat dan mobile. Pada penelitian ini elektroda glassy karbon yang kurang elektroaktif terhadap spesi kromium VI dan Kromium III, dimodifikasi dengan komposit grafena-nanopartikel Au yang dielektrodeposisi secara simultan dengan teknik cyclic voltammetry CV pada permukaan elektroda glassy karbon untuk meningkatkan sensitifitasnya, untuk kemudian digunakan dalam analisis spesiasi ion logam kromium VI dengan teknik square wave siklik voltmmetry SWSV dan Linear Scan Voltammety LSV dan penetuan kromium III dengan teknik cyclic voltammetry.
Elektroda glassy karbon termodifikasi dikarakterisasi dengan Scanning Electron Microscopy SEM, Fourier Transform Infrared Spectroscopy FTIR, X-Ray Diffraktofotometry XRD dan persamaan Randless-Sevcik. Konduktifitas yang tinggi dan luas permukaan yang besar pada grafena, menjadikan grafena menjadi tempat fiksasi/pertumbuhan nanopartikel Au yang bersifat elektrokatalisis terhadap logam kromium, dan memiliki konstribusi yang besar dalam meningkatkan sinyal arus listrik/sensitifitas pada analisis spesiasi ion logam Cr VI dan Cr III dengan teknik SWSV dan LSV pada rentang linear 0,01 ppm hingga 0,35 ppm dengan nilai limit deteksi LoD 48,7 ppb, dan untuk penentuan Cr III dengan teknik CV pada rentang linear 0,01 ppm hingga 0,35 ppm dengan nilai LoD 33,81 ppb dan LoQ 112,70 ppm. Elektroda kemudian digunakan untuk mendeteksi ion logam Cr VI dalam air danau di lingkungan universitas Indonesia dan didapatkan kadar sebesar 74,33 ppb dan hasilnya dibandingkan dengan metode pembentukan kompleks Cr-Difenil Karbazon yang ditentukan secara UV-Vis spectrofotometri dengan perbedaan hasil sebesar 30,88.

The consumption of clean and healthy water is the necessity of every living being. According to WHO, the concentration of more than 50 ppb of chromium VI ions in drinking water can harmfull for human health. So, we need a method of determining the concentration of chromium ion VI in a simple way, easy, cheap, fast and mobile. In this study, an electroactive glassy carbon electrode modified with graphene and Au Nanoparticles composites, for quantification to chromium VI and Chromium III species, are simultaneously electrodeposited with cyclic voltammetry CV techniques on the surface of glassy carbon electrodes to increase their sensitivity, and then used in the speciation analysis of the of chromium metal ions VI with square wave cyclic voltammetry SWSV and Linear Scan Voltammety LSV and for chromium III determined by cyclic voltammetry technique.
The modified glassy carbon electrode is characterized by Scanning Electron Microscopy SEM, Fourier Transform Infrared Spectroscopy FTIR, X Ray Diffractofotometry XRD and Randless Sevcik equations. The high conductivity and large surface area of the graphene make the graphene as fixation site for an electrocatalytic gold nanoparticles growth, and has a large contribution for improving electrical current signals sensitivity in speciation analysis of Cr VI and Cr III with SWSV and LSV technique with linear range at 0.01 ppm to 0.35 ppm and detection limit LoD of 48.7 ppb, and for determination of Cr III with CV technique with linear range from 0.01 ppm to 0.35 ppm with value of LoD is 33.81 ppb and value of LoQ is 112.70 ppm. The modified electrode then used to detect Cr VI metal ions in lake water in Universitas Indonesia and obtained a concentration of Chromium VI is 74.33 ppb and the results were compared with formation of Cr diphenyl carbazon complex method by UV Vis spectrophotometry with yield difference of 30, 88 .
"
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2018
T51335
UI - Tesis Membership  Universitas Indonesia Library
cover
Ivandini Tribidasari Anggraningrum
"ABSTRACT
In order to shorten the measurement time of biochemical oxygen demand (BOD), a BOD sensor based on yeast metabolism was developed. Local yeast, Indonesian Origin, Candida fukuyamaensis UICC Y-247, was used as a transducer. The yeast was immobilized as a thin film in ag
arose matrix with the auxiliary of Nafion® acting as the membrane for ion exchange process. The film was then attached to gold-modified glassy carbons and used as transducer on the working electrodes. The measurements were conducted by observing the depletion of glucose concentration using multipulse amperometric method and then converte
d to BOD values. Optimum condition was observed in a waiting measurement time of 30 min at an applied potential of 450 mV (vs.
Ag/AgCl). Linearity was shown in glucose concentration range of 0.1?0.5 mM, which was equivalent to BOD concentration range of 10?50 mg/L. A detection limit of 1.13 mg/L BOD could be achieved. Good repeatability was shown by a relative standard deviation (RSD) of
2.7% (n = 15). However, decreasing current response of ~50% was found after 3 days. Comparing to the conventional BOD measurement, this BOD sensor can be used as an alternative method for BOD measurements. "
[Direktorat Riset dan Pengabdian Masyarakat UI;Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia;Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia;Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, Universitas Indonesia], 2011
J-Pdf
Artikel Jurnal  Universitas Indonesia Library
cover
Malikussaid
"Dalam penelitian yang dilakukan sebelumnya tentang Pengembangan Sensor Elektrokimia untuk Spesiasi Kromium menggunakan Elektroda Glassy Carbon yang Dimodifikasi dengan Nanopartikel Emas dan Grafena (Yuanda, 2018), telah ditemukan bahwa elektroda karbon serupa gelas termodifikasi emas dan grafena memberikan hasil deteksi yang baik terhadap Cr(III) dan Cr(VI). Penelitian ini bertujuan untuk menentukan modifikasi terbaik, baik yang telah dilakukan dalam penelitian tersebut maupun dengan mengganti nanopartikel emas dengan nanopartikel platinum. Kemudian, penelitian ini juga menentukan pH kerja optimal dari elektroda tersebut. Modifikasi elektroda dilakukan dengan metode elektrodeposisi dengan menggunakan voltametri siklik dengan net arus ke arah potensial negatif. Deposisi dengan HAuCl4 dan K2PtCl6 dilakukan dalam suasana asam dari HCl, sementara deposisi grafena dilakukan dalam medium air. Hasil pengukuran menunjukkan bahwa kinerja elektroda paling sensitif adalah dengan modifikasi grafena dan nanopartikel emas dalam pH kerja 5. Dibandingkan dengan modifikasi lain, respon arus terhadap Cr(VI) pada elektroda glassy carbon termodifikasi grafena dan nanopartikel emas menunjukkan linearitas yang sangat baik (r2 = 0,952) pada rentang konsentrasi 4 ppm sampai dengan 80 ppm dan reprodusibilitas yang baik dalam pengulangan 3 kali. Hal ini menunjukkan bahwa elektroda karbon serupa gelas termodifikasi grafena dan nanopartikel emas memiliki sensitivitas yang tinggi, dengan harga gradien arus terhadap konsentrasi sebesar +1,38E-4 μA/ppb, dibuktikan dengan kemampuan deteksi pada rentang 4 ppm sampai dengan 80 ppm dan dapat digunakan sebagai sensor kadar kromium heksavalen dalam larutan.

In previous research titled Development of Electrochemical Sensor for Chromium Speciation with Glassy Carbon Electrode Modified using Gold Nanoparticles and Graphene (Yuanda, 2018), it has been found out that graphene and gold nanoparticles modified glassy carbon electrode is providing a good detection result for trivalent and hexavalent Chromium. This research aims to find the best modification, either modification that had been done on previous research mentioned above or replacing the gold nanoparticles with platinum nanoparticles. Then this research also attempts to decide the best working pH for the electrode. Electrode modification is being done with the electrodeposition method using cyclic voltammetry with net current towards negative direction. Deposition with Chloroauric (III) Acid Tetrahydrate and Potassium Hexachloroplatinate (VI) is being done in an acidic condition provided by Hydrochloric Acid. Meanwhile, Graphene deposition is done with a solution of Graphene dissolved in demineralized water. The result of the measurements shows that the best performing, most sensitive electrode is the one modified with Graphene and gold nanoparticles, in a solution with a working pH of 5. Compare to other electrode modifications, the current response against hexavalent Chromium concentration with the glassy carbon electrode modified with Graphene and gold nanoparticles shows excellent linearity (r2 = 0.952) in the concentration ranging from 4 ppm w/w to 80 ppm w/w with excellent reproducibility when the measurement is done thrice. Therefore, this research shows that glassy carbon electrode modified by graphene and gold nanoparticles have a high sensitivity, having current gradient in response to variation in concentration of +1,38E-4 μA/ppb, proven by the detection result in the concentration ranging from 4 ppm w/w to 80 ppm w/w, and hence could be used as a sensor for the content of hexavalent Chromium in solution."
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2019
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
<<   1 2 3 4 5 6 7 8 9 10   >>