Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 80763 dokumen yang sesuai dengan query
cover
Bambang Suharno
"Failures of magnesia-chrome refractory at Peirce Smith Converter caused unstable production process. This research was carried out to find failures factor by determined shell temperatures distribution, thickness of refractories consumption and testing of converter slag samples Final result of this research have indicated that refractories failure was caused by non any form of silica flux and scraps that was influenced by feed chutes design that didn?t work optimally to distribute silica flux and scrap good than it made high local temperature in converter increased Redesign chute have done to make balance of silica flax, scrap adding and operating temperatures distribution than be hoped it able to increase the lifetime of refractory."
Depok: Fakultas Teknik Universitas Indonesia, 2001
JUTE-15-3-Sep2001-311
Artikel Jurnal  Universitas Indonesia Library
cover
cover
Wahyuni Martiningsih
Depok: Fakultas Teknik Universitas Indonesia, 2002
TA3300
UI - Tugas Akhir  Universitas Indonesia Library
cover
"Pemodelan proses yang baik membutuhkan model sifat-sifat termodinamika yang
akurat dan elisien dalam perhilungan untuk rentang tekanan, temperature dan komposisi
yang lebar.
Metode yang efektif dalam menentukan sifat-sifat termodinamika adalah dengan
menggunakan persamaan keadaan yang mengambil bentuk umum persamaan van der
Waals.
Persamaan keadaan yang paling baik untuk dikembangkan adalah persamaan
kubik tiga parameter dengan parameter a sebagai fungsi temperature. Perbaikan
perhitungan volume cair jenuh dapat dilakukan dengan menerapkan translasi volume
pada persamaan keadaan yang diinginkan.
Aplikasi volume translasi dapat meningkatkan akurasi perhirungan volume cair
jenuh. Pada aplikasinya translasi volume mempunyai akurasi yang tinggi pada
persamaan Peng-Robinson, dimana faktor koreksinya merupakan fungsi temperatur."
Fakultas Teknik Universitas Indonesia, 2002
S49311
UI - Skripsi Membership  Universitas Indonesia Library
cover
Arys Nursetyawan
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2005
TA486
UI - Tugas Akhir  Universitas Indonesia Library
cover
Ratu Mahdiyah Nabilah
"Latar belakang: Hidroksiapatit merupakan salah satu bahan alloplast yang banyak digunakan di bidang kedokteran gigi. Komposisi hidroksiapatit sama dengan komposisi anorganik tulang dan gigi manusia sehingga bersifat biokompatibel dan bioaktif. Selain itu, hidroksiapatit juga bersifat osteokonduktif. Salah satu metode pembuatan hidroksiapatit yaitu metode disolusi-presipitasi dalam kondisi hidrotermal. Pembuatan blok hidroksiapatit dengan metode disolusi-presipitasi pada suhu 100°C selama 48 jam masih menghasilkan fasa lain selain hidroksiapatit, yaitu dicalcium phosphate anhydrous (DCPA). Fasa DCPA dan/atau fasa DCPD (dicalcium phosphate dehydrate) dapat terbentuk dalam pH asam. Sedangkan, hidroksiapatit dapat terbentuk pada pH basa. Oleh karena itu, pH dapat dijadikan indikator secara tidak langsung mengenai hasil fasa yang terbentuk. Gipsum dipilih sebagai prekursor karena mengandung ion kalsium (Ca2+). Sedangkan, larutan Na3PO4 digunakan karena mengandung ion fosfat (PO43-), bersifat tidak toksik, dan memiliki pH basa.
Tujuan: Penelitian ini bertujuan untuk mengetahui pengaruh perbedaan suhu terhadap perubahan pH larutan Na3PO4 dalam pembuatan blok hidroksiapatit dari blok gipsum.
Metode Penelitian: Penelitian ini menggunakan blok gipsum dan larutan Na3PO4 sebagai prekursor untuk membuat blok hidroksiapatit. Spesimen yang digunakan berupa 30 mL larutan 1 mol/L Na3PO4 sebanyak dua beaker glass larutan. Sebelum dilakukan perendaman, pH larutan diukur terlebih dahulu untuk mengetahui pH awal larutan 1 mol/L Na3PO4. Lima belas blok gipsum direndam dalam 30 mL larutan 1 mol/L Na3PO4 dengan suhu yang berbeda yaitu 100°C, 140°C, dan 180°C pada kondisi hidrotermal selama 48 jam. Setelah perendaman, blok dan larutan 1 mol/L Na3PO4 dipisahkan. Kemudian, pH larutan 1 mol/L Na3PO4 diukur kembali menggunakan pH meter Eutech Instruments pH 700 untuk mendapatkan pH larutan 1 mol/L Na3PO4 setelah digunakan untuk perendaman selama 48 jam.
Hasil: Nilai pH larutan 1 mol/L Na3PO4 sebelum digunakan untuk perendaman yaitu 13,04. Sedangkan, nilai pH larutan 1 mol/L Na3PO4 setelah digunakan untuk perendaman pada suhu 100°C, 140°C, dan 180°C berturut-turut yaitu 12,72; 12,67; dan 12,30.
Kesimpulan: Peningkatan suhu yang digunakan menyebabkan penurunan pH larutan 1 mol/L Na3PO4. Namun, pH akhir larutan masih cukup basa untuk hidroksiapatit terbentuk. Namun, penelitian lebih lanjut masih perlu dilakukan mengenai pengukuran pH larutan Na3PO4 dengan sampel yang lebih banyak.

Background: Hydroxyapatite is one of the alloplastic materials that is widely used in dentistry. The composition of hydroxyapatite is similar with the inorganic composition of human bone so that it is biocompatible and bioactive. Besides, hydroxyapatite is also osteoconductive. One of the fabrication methods of hydroxyapatite is the dissolution-precipitation method under hydrothermal conditions. The fabrication of hydroxyapatite block with the dissolution-precipitation method at 100°C for 48 hours still produced other phase except hydroxyapatite, specifically dicalcium phosphate anhydrous (DCPA). DCPA and/or dicalcium phosphate dehydrate (DCPD) phase can be obtained if the pH is acidic. Meanwhile, hydroxyapatite can be fabricated on the alkaline pH condition. Therefore, the pH value can be the indirect indicator to predict the phase product. Gypsum was chosen as a precursor because it has calcium ions (Ca2+). Na3PO4 solution was used because it contained phosphate ions (PO43+), non-toxic, and has an alkaline pH value.
Objective: This study aimed to determine the effect of temperature differences on changes of the pH value of Na3PO4 solution in the fabrication of hydroxyapatite block from gypsum block.
Methods: This study used gypsum block and Na3PO4 solution as precursors to fabricate hydroxyapatite block. The specimens of this study were two beaker glasses of 30 mL of 1 mol/L Na3PO4 solution. Before the immersion, the pH value of the solution was measured first to determine the initial pH value of 1 mol/L Na3PO4 solution. Fifteen specimens of gypsum blocks were immersed in 30 mL of 1 mol/L Na3PO4 solution with different temperatures specifically 100°C, 140°C, and 180°C under the hydrothermal condition for 48 hours. After the immersion, the blocks and the 1 mol/L Na3PO4 solution were separated. Then, the pH value of 1 mol/L Na3PO4 solution was measured using Eutech Instruments pH 700 pH meter to obtain the pH of 1 mol/L Na3PO4 solution after being used for immersion for 48 hours.
Results: The pH value of 1 mol/L Na3PO4 solution before being used for the immersion was 13,04. Meanwhile, the pH value of 1 mol/L Na3PO4 solution after being used for the immersion at 100°C, 140°C, and 180°C respectively were 12.72, 12.67, and 12.30.
Conclusions: The increase in the temperature caused the derivation of the pH value of 1 mol/L Na3PO4 solution. Nevertheless, the final pH value was still alkaline enough for hydroxyapatite to be formed. However, further research still needs to be done to measure the pH value of the Na3PO4 solution with more samples.
"
Jakarta: Fakultas Kedokteran Gigi Universitas Indonesia, 2021
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
"Quality of asphalts mixing in construction work as road povement material, on site was ejected by
many factors. One of that is temperature when act of cramming periode. For having od one force
material with good quality, controlling to act of cramming temperature was handel since the mix out from
mixing plane (AMP) until spreading period and force density on site. Temperature dicease in spreading
and density periode. Exactly will result quality and ashpalt mix will decrease. To getting know about
temperatur density on ashpalt posed Therefore in this research made laboratorium experiment where is
density temperature variable star from 140°C decrease until 70°C with interval decreasing 10° C
temperature. Result of observation in laboratorium experiment. Show that force density temperature
below 124,5"C resulting technical attitudes that is not foraging. For those is suggested that forces density
temperature is around 124,5°C - 140°C.
"
Jurnal Teknologi, 15 (2) Juni 2001 : 157-165, 2001
JUTE-15-2-Jun2001-157
Artikel Jurnal  Universitas Indonesia Library
cover
"Salah satu metode unruk menurunkan nickel loss pada proses converter
dengan Pierce Smith Converter adalah dengan melakukan settling time pada saat
sebelum skimming dan sesudah blowing. Dengan begitu diharapakan nlkel yang
bercampur bersama slag mempunyai cukup waktu untuk berpenetrasi ke bawah.
Selain itu besar kecilnya nickel loss juga kernungkinan dipengamhi oleh
parameter proses yang lain seperti grade nickel EFM ( Electric Furnace Matte )
yang masuk ke converter dan temperatur proses.
Penelitian pada proses converter dilakukan dengan tahapan, pertama
mengambil data EFM untuk mengetahui grade nickel EFM sehingga bisa
dibandingkan dengan nickel loss yang terjadi_ Kedua, mengukur temperatur EFM
dan temperatur slag yang dapat menggambarkan temperatur proses dari converter.
Ketiga, rnengambil sampel slag converter untuk mengetahui berapa komposisi
nikel pada pada low nickel slag (nickel loss) converter apabila dilakukan non
settling time, settling time 3 menit dan settling time 5 menit.
Hasil penelitian menunjukan apabila proses converter tidak dilalcukan
settling time menghasilkan nickel loss sebesar 0,59%, dengan settling time 3 menit
dihasilkan nickel loss sebesar 0,5l% dan dengan settling time 5 menit nickel loss
yang teljadi sebesar 0,50%. Berdasarl-can perhitungan waktu operasi converter
diketahui bahwa untuk settling time baik yang 3 menit ataupun 5 menit dapat
dilakukan tanpa memgikan waktu operasi. Keuntungan perusahaan yang dapat
diambil apabila dilakukan settling time 3 menit sebesar $ l.7’l2.210,52 dan untuk
settling time selama 5 menit sebesar $ l_993_736,7 setiap tahun, dengan asumsi
harga nikel $ 1 per pounds (lbs).
Penelitian juga menunjukan bahwa grade nickel EFM berpengaruh
terhadap nickel loss dan Total Operating Time (TOT) converter, di mana semakin
rendah grade nickel EFM malta semakin tinggi nickel loss yang teljadi dan proses
converter semakin lama. Temperatur juga berpengaruh terhadap nickel loss
converter, yaitu semakin tinggi temperatur proses converter maka semakin rendah
nickel loss yang terjadi,"
Fakultas Teknik Universitas Indonesia, 2002
S41431
UI - Skripsi Membership  Universitas Indonesia Library
cover
cover
<<   1 2 3 4 5 6 7 8 9 10   >>