Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 66958 dokumen yang sesuai dengan query
cover
Konita Nur Khasanah
"Tujuan penelitian ini untuk mengetahui pengaruh penggunaan sumber sinar berbeda terhadap kekuatan tarik diametral resin komposit bulk-fill. Resin komposit bulk-fill Tetric N-Ceram Bulk Fill dibuat sebanyak 20 spesimen berbentuk lempeng dengan diameter 6 mm dan tebal 3 mm. Spesimen dibagi menjadi dua kelompok yaitu kelompok yang disinari dengan sumber sinar QTH dan sumber sinar LED. Uji kekuatan tarik diametral dilakukan dengan menggunakan Universal Testing Machine. Hasil penelitian menunjukkan nilai rerata kekuatan tarik diametral resin komposit bulk-fill yang disinari sumber sinar QTH dan LED sebesar 38.62 2.34 dan 42.02 3.21. Hasil uji independent sample T menunjukkan nilai rerata pada kedua kelompok berbeda bermakna.

This study aimed to evaluate the effect of using different light sources on the diametral tensile strength of bulk fill resin composite. Bulk fill resin composite Tetric N Ceram Bulk Fill was used to make of 20 disc shape specimens with 6 mm in diameter and 3 mm in thickness. Specimens were divided into two groups, the two groups were polymerized with using QTH and LED light source curing unit. Diametral tensile strength test was conducted by using a Universal Testing Machine Shimadzu, Japan. The results showed that diametral tensile strength mean value of bulk fill resin composite that were cured with QTH and LED light source were 38.62 2.34 and 42.02 3.21 MPa respectively. Independent sample t test results showed that the mean value of the two groups was significantly different."
Jakarta: Fakultas Kedokteran Gigi Universitas Indonesia, 2016
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Napitupulu, Elizhabet
"Tujuan penelitian ini adalah untuk mengetahui pengaruh jarak sumber sinar Light Emitting Diode (LED) terhadap kekuatan tarik diametral resin komposit bulk-fill. Resin komposit bulk-fill Tetric® N-Ceram Bulk-Fill, shade IVA (setara dengan warna VITA A2-A3) dibuat menjadi 30 spesimen berbentuk silinder dengan ukuran tebal 3 mm dan diameter 6 mm. Spesimen dibagi menjadi 3 kelompok variasi jarak penyinaran, yaitu 0 mm, 3 mm dan 5 mm. Penyinaran menggunakan LED Light Curing Unit Bluephase® Style (Ivoclar-Vivadent, Liechtenstein) dengan durasi penyinaran selama 10 detik sesuai instruksi pabrik. Data dianalisis secara statistik menggunakan metode ANOVA satu arah. Hasil analisis tidak menunjukkan perbedaan bermakna (p>0,05) pada semua kelompok. Jarak sumber sinar LED ≤ 5 mm tidak memberikan pengaruh yang signifikan terhadap kekuatan tarik diametral resin komposit bulk-fill.

This study aimed to evaluate the effect of LED light source distance on diametral tensile strength of bulk-fill composite restorative material. Bulk-fill composite Tetric® N-Ceram Bulk-Fill, shade IVA (equal to VITA shade A2-A3) was formed into 30 cylindrical specimens with 3 mm in thickness and 6 mm in diameter. Specimens were divided into 3 groups with various curing distance: 0 mm, 3 mm and 5 mm. All groups were polymerized by LED Light Curing Unit Bluephase® Style (Ivoclar-Vivadent, Liechtenstein) for 10 seconds based on manufacturer’s instruction. Data were statistically analyzed by one-way ANOVA The result showed insignificant differences in all groups (p>0,05). LED light source distance ≤ 5 mm was not significantly affected the diametral tensile strength of bulk-fill composite."
Jakarta: Fakultas Kedokteran Gigi Universitas Indonesia, 2015
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Rivandy Holil
"Latar Belakang: Dalam dunia kedokteran gigi, terdapat banyak pilihan material restoratif yang dapat digunakan, salah satunya yaitu resin komposit. Seiring dengan perkembangan teknologi, para peneliti berhasil mengembangakan resin komposit baru yaitu Bulk-Fill. Sebagai contoh adalah resin komposit Giomer Bulk-Fill yang memiliki berbagai sifat seperti sifat mekanik, fisis dan biologis. Namun, belum ada penelitian pada resin komposit Giomer Bulk-Fill yang secara spesifik menguji nilai kekuatan tarik diametral yang merupakan salah satu sifat mekanik material restoratif.
Tujuan Penelitian: Penelitian ini bertujuan untuk mengetahui pengaruh lama perendaman 1, 24, dan 72 jam serta perbedaan nilai pH saliva buatan 7; 5,5; dan 4,5 terhadap kekuatan tarik diametral resin komposit Giomer Bulk-Fill.
Metode: Penelitian eksperimental laboratorik dengan menggunakan 90 spesimen berbentuk silindris pejal dengan diameter 6 mm dan tinggi 3 mm yang diuji menggunakan Universal Testing Machine (Shimadzu AGS-X 5kN, Japan) dan dibagi ke dalam 3 kelompok pH larutan saliva buatan yaitu 7; 5,5; dan 4,5; serta 3 kelompok lama perendaman yaitu 1, 24, dan 72 jam.
Hasil: Hasil pengujian menggunakan uji One-way ANOVA menunjukkan adanya perbedaan bermakna pada spesimen-spesimen yang digunakan (p<0,05). Pada kelompok spesimen yang direndam dalam larutan saliva buatan dengan pH 7, hasil rerata kekuatan tarik diametral pada perendaman selama 1 jam adalah sebesar 36,7 ± 2,7 MPa. Kemudian mengalami penurunan setelah perendaman 24 jam dengan rerata nilai kekuatan tarik diametralnya sebesar 35,2 ± 2,2 MPa dan meningkat kembali setelah perendaman 72 jam dengan hasil rerata kekuatan tarik diametralnya sebesar 40,1 ± 3,6 MPa. Pada kelompok spesimen yang direndam dalam larutan saliva buatan dengan pH 4,5, pada perendaman selama 1 jam hasil rerata kekuatan tarik diametralnya sebesar 33,6 ± 2,4 MPa. Kemudian setelah perendaman 24 jam dan 72 jam meningkat menjadi 42,6 ± 2 MPa dan 44,2 ± 2,8 MPa. Pada kelompok spesimen yang direndam dalam larutan saliva buatan dengan pH 5,5, hasil rerata kekuatan tarik diametral setelah perendaman selama 1 jam adalah sebesar 34 ± 2,4 MPa. Namun, terjadi perbedaan jika dibandingkan dengan kelompok pH 4,5 yaitu pada kelompok dengan pH 5,5 pada lama perendaman 24 jam terjadi peningkatan yaitu sebesar 44,7 ± 2,8 MPa kemudian menurun setelah perendaman 72 jam dengan nilai rerata sebesar 39 ± 3,3 MPa.
Kesimpulan: Nilai kekuatan tarik diametral resin komposit Giomer Bulk-Fill tidak dipengaruhi oleh pH saliva buatan 4,5; 5,5; dan 7 yang digunakan di dalam penelitian ini. Nilai kekuatan tarik diametral resin komposit Giomer Bulk-Fill yang direndam selama 1, 24, dan 72 jam di dalam saliva buatan dengan pH 4,5; 5,5; dan 7 secara umum mengalami peningkatan sehingga lama perendaman dalam penelitian ini mempengaruhi nilai kekuatan tarik diametral resin komposit Giomer Bulk-Fill.

Background: In the world of dentistry, there are many choices of restorative materials that can be used, one of them is composite resin. Along with the development of technology, the researchers succeeded in developing a new composite resin called Bulk-Fill. One example is Giomer Bulk-Fill composite resin which has various properties such as mechanical, physical and biological properties. However, there is no research on Giomer Bulk-Fill composite resin which specifically tests the value of diametral tensile strength which is one of the mechanical properties of restorative material.
Objective: This study aims to determine the effect of immersion time and the difference in pH value 7; 5,5; and 4,5 of the artificial saliva solution on the value of diametral tensile strength of Giomer Bulk-Fill composite resin.
Method: Laboratory experimental research using 90 solid cylindrical specimens with a diameter of 6 mm and a height of 3 mm which were tested using Universal Testing Machine (Shimadzu AGS-X 5kN, Japan) and were divided into 3 groups pH of artificial saliva solution (7; 5.5; and 4.5) and 3 groups of immersion periods (1, 24 and 72 hours).
Results: The test results using the One-way ANOVA test showed significant differences in the specimens used (p <0.05). In the group of specimens which were immersed in artificial saliva solution with pH 7, the results of the average diametral tensile strength at immersion for 1 hour were 36.7 ± 2.7 MPa. Then it decreased for 24 hours immersed time with a mean value of diametral tensile strength of 35.2 ± 2.2 and increased again at 72 hours immersed time with an average value of diametral tensile strength 40.1 ± 3.6 MPa. In the group of specimens which were immersed in artificial saliva solution with pH 4.5, at immersion for 1 hour the average value of diametral tensile strength was 33.6 ± 2.4 MPa. Then in 24-hour and 72-hour immersion, it increased to 42.6 ± 2 MPa and 44.2 ± 2.8 MPa. In the group of specimens immersed in artificial saliva solution with a pH of 5.5, the average value of diametral tensile strength for 1 hour was 34 ± 2.4 MPa. However, there was a difference when compared to the pH 4.5 group, which was in the group with a pH of 5.5 in the 24-hour immersion period, the value increase for 44.7 ± 2.8 MPa and then decreased for 72 hours of immersion with an average value of 39 ± 3.3 MPa.
Conclusion: The value of diametral tensile strength of Giomer Bulk-Fill composite resin is not affected by pH of artificial saliva 4.5; 5.5; and 7 that used in this study. The value of diametral tensile strength of Giomer Bulk-Fill composite resin, which is immersed for 1, 24, and 72 hours in artificial saliva with pH 4.5; 5.5 and 7 generally increased so that the immersion time in this study affected the diametral tensile strength of Giomer Bulk-Fill composite resin.
"
Jakarta: Fakultas Kedokteran Gigi Universitas Indonesia, 2018
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Trihanna Kezya Rima
"Penelitian ini bertujuan untuk mengetahui pengaruh perendaman minuman isotonik terhadap kekerasan permukaan resin komposit bulk-fill. Enam puluh spesimen Tetric N-Ceram Bulk-Fill berdiameter 6 mm dan tinggi 3 mm dibagi menjadi 2 kelompok perendaman yaitu dengan akuades (kontrol) dan minuman isotonik. Setiap kelompok direndam dengan lama perendaman 1 hari, 3 hari dan 7 hari. Kekerasan permukaan diuji menggunakan HMV-G Series Micro Vickers Hardness Tester.
Hasil menunjukan terdapat perbedaan bermakna (p<0,05) antara perendaman akuades dan minuman isotonik uji Independent T-Test. Hasil menunjukkan bahwa terdapat perbedaan bermakna (p<0,05) antara semua kelompok perendaman minuman isotonik dengan lama perendaman 1 hari, 3 hari dan 7 hari dengan uji statistik One-Way Anova dan PostHoc Tukey HSD. Dapat disimpulkan bahwa minuman isotonik mempengaruhi kekerasan permukaan resin komposit bulk-fill.

This study aims to determine the influence of isotonic drink immersion on surface hardness of bulk-fill composite. Sixty specimens of Tetric N-Ceram Bulk-Fill, 6 mm in diameter and 3 mm height were divided into two groups of storage media; deionized water (control) and isotonic drink. Each group was for 1 day, 3 days and 7 days. The surface hardness is measured using a HMV-G Series Micro Vickers Hardness Tester.
The results showed that there were significant differences (p <0.05) between immersion of control and isotonic drink with Independet T-Test. The results showed that there were significant differences (p <0.05) between all isotonic drink immersion groups with immersion duration of 1 day, 3 days and 7 days with One-Way Anova Test and Post Hoc Tukey HSD. It can be concluded that isotonic drinks affect the surface hardness of bulk-fill composite.
"
Jakarta: Fakultas Kedokteran Gigi Universitas Indonesia, 2018
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Mohammad Mutawalli Makhbubi
"Latar belakang: LCU-LED prototipe metode PWM iradiansi 900 dan 1.000 mW/cm2 telah dibuat untuk mengurangi panas dengan lama penyinaran 10 detik.
Tujuan: Menganalisis pengaruh iradiansi terhadap kekuatan tarik diametral komposit resin nanofil.
Metodologi: Spesimen disinar dengan LCU-LED prototipe iradiansi 900 dan 1.000 mW/cm2 serta LCU pembanding (900 mW/cm2). Komposit resin nanofil ditumpat ke dalam cetakan stainless steel. Uji kekuatan tarik diametral dilakukan menggunakan Universal Testing Machine. Analisis statistik menggunakan One-way ANOVA dan LSD(α=0.05).
Hasil penelitian: Kekuatan tarik diametral dari iradiansi 900,1.000 mW/cm2 dan LCU pembanding secara berurutan adalah 48,75±5,3, 49,85±7,7 dan 49,48±5,3 MPa. Analisis statistik menunjukkan bahwa tidak terdapat perbedaan bermakna pada semua kelompok (p>0.05).
Kesimpulan: Tidak terdapat pengaruh iradiansi sinar 900 dan 1000 mW/cm2 terhadap kekuatan Tarik diametral komposit resin nanofil.

Background: Prototype LCU-LED using PWM with irradiance 900 and 1,000mW/cm2 has constructed that can reduce temperature for polymerizing in ten seconds.
Objective: To analyze the effect of difference irradiance on diametral tensile strength of the composite resin nanofilled.
Method: Speciments were polymerized using the prototype with irradiance of 900, 1.000 mW/cm2 and commercially avaiable(900 mW/cm2) as comparison. Diametral tensile strength was determined using Universal Testing Machine. Data were analyzed using One-way ANOVA followed by LSD(α=0,05).
Result: Value of diametral tensile strength irradiance 900,1.000 mW/cm2 and commercial avaiable were 48.75 ± 49.85 ± 5.3 MPa and 7.7 MPa respectively. Statistical analysis showed that there was no significant difference in groups(p>0.05).
Conclusion: There is no effect of light irradiance on the diametral tensile strength of composite resin nanofilled.
"
Jakarta: Fakultas Kedokteran Gigi Universitas Indonesia, 2015
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Dessy Innawaty
"Penelitian ini bertujuan untuk mengevaluasi pengaruh durasi penyinaran menggunakan LED dan pemanasan awal menggunakan Micerium ENA Heat terhadap depth of cure resin komposit bulk-fill. Alat dan bahan: Enam puluh spesimen Filtek Bulk-Fill Posterior Restoratives ketebalan 4 mm dan diameter 3 mm; tanpa dan dengan pemanasan awal pada temperatur 39 C dibagi ke dalam 3 kelompok sesuai dengan durasi penyinaran 5 detik, 10 detik, dan 15 detik. Spesimen dipolimerisasi menggunakan LED Curing Unit 3MTM Elipar, 1.200 mW/cm2 dan diuji kekerasan mikro menggunakan Vickers Microhardness Tester Shimadzu, Japan untuk menghitung nilai depth of cure. Data yang diperoleh dianalisis menggunakan uji statistik Kruskall-Wallis dan Post-Hoc Mann Whitney-U.
Hasil: Adanya perbedaan yang tidak bermakna p ge;0,05 untuk nilai depth of cure pada keenam kelompok tanpa dan dengan pemanasan awal. Walaupun nilai depth of cure tersebut tidak bermakna namun telah mencapai nilai minimum yaitu ge; 80. Selain itu terdapat perbedaan yang bermakna p.

Aim Evaluate the influence of different exposure time and pre heating on its depth of cure of bulk fill composite. Methods Sixty cylinder shaped specimens of Filtek Bulk Fill Posterior Restoratives 4 mm of thickness x 3 mm of diameter with and without pre heating at 39 C were divided into 3 subgroups according to exposure times 5, 10, and 15. All specimens were polymerized using LED Curing Unit 3MTM Elipar, 1.200 mW cm2 and tested using Vickers Microhardness Tester Shimadzu, Japan to determine its microhardness for calculating its depth of cure. Data were statistically analyzed using Kruskall Wallis and Post Hoc Mann Whitney U test.
Results A no significant differences p ge 0,05 in depth of cure amongst the six groups of non preheated and preheated bulk fill composite. However, all of the groups have reached a minimum value of ge 80 depth of cure. Moreover, there is a significant differences in microhardness in all of the six groups of non preheated and preheated bulk fill composite and between 5 and 15 of exposure times in both groups. Conclusion Exposure times and pre heating at 39 C had an influence on microhardness of bulk fill composite.
"
Jakarta: Fakultas Kedokteran Gigi Universitas Indonesia, 2017
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Kiemas Muhammad Naufal Elsinaz
"ABSTRAK
Penelitian ini bertujuan untuk mengetahui pengaruh jarak penyinaran terhadap kekuatan tarik diametral dari material restorasi resin komposit alkasit. Tigapuluh dua spesimen material restorasi resin komposit alkasit Cention-N, Ivoclar-Vivadent, Liechtenstein berbentuk lempengan dengan ketebalan 3 mm dan diameter 6 mm n=32 dibagi menjadi dua kelompok dengan jarak penyinaran 0 dan 2 mm n=16 . Spesimen dipolimerisasi menggunakan LED curing unit, iradiansi 800 mW/cm2 selama 30 detik. Spesimen diuji menggunakan Universa Mechanicall Testing Machine 250 kgf, 0,5 mm/menit, Shimadzu, Japan untuk mendapatkan nilai kekuatan tarik diametral. Hasil uji statistik Independent Sample T-Test menunjukkan bahwa kekuatan tarik diametral menurun namun tidak signifikan terutama pada kelompok dengan jarak penyinaran 2 mm. Disimpulkan bahwa jarak penyinaran dapat mempengaruhi nilai kekuatan tarik diametral.

ABSTRACT
The aim of this study is to analyze the effect of light curing distance on diametral tensile strength of alkasite composite resin restoration material. Thirty two disc shaped specimens of alkasite composite restoration material Cention N, Ivoclar Vivadent, Liechtenstein with 3 mm thickness and 6 mm of diameter n 32 were divided into two different light curing distance groups 0 and 2 mm n 16 . All Specimens were polymerized using LED curing unit, irradiance 800 mW cm2 for 30 s. Specimens were tested using Universal Mechanical Testing Machine 250 kgf, 0,5 mm menit to determine its diametral tensile strength. The statistical results from Independent Sample T Test, showed that diametral tensile strength of 2 mm light curing distance group were decreased, but not significantly .It was concluded that light curing distance has effect on the diametral tensile strength of composite resin alkasite material."
2018
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Riza Hakim Fazlurrahman Zaini
"Salah satu upaya kontrol infeksi terhadap LED-curing unit (LCU) adalah menggunakan plastik transparan (cling wrap). Untuk mengetahui pengaruh penggunaan LCU yang dilapisi cling wrap dalam variasi jarak penyinaran terhadap kekuatan tarik diametral resin komposit, dibuatlah 60 spesimen yang disinari dengan LCU berlapis dan tanpa pelapis dalam 6 variasi jarak penyinaran (0,5-5 mm). Spesimen diuji dengan uji tekanan diametral menggunakan Universal Testing Machine. Dengan hasil uji statistik yang memperlihatkan perbedaan bermakna (p<0,05) antara kelompok yang disinari dengan LCU berlapis dan tanpa pelapis, disimpulkan bahwa penggunaan LCU yang dilapisi cling wrap memberikan pengaruh pada kekuatan tarik diametral resin komposit.

One of infection control method for LED-curing unit (LCU) is by using transparent plastic barrier (cling wrap). To evaluate the influence of using plasticwrapped LCU in curing distance variances to diametral tensile strength of composite resin, 60 disc-shaped specimens are formed and cured by using plasticwrapped and unwrapped LCU in 6 groups of curing distance (0.5-5 mm). The diametral compression test is done by using Universal Testing Machine. The result of statistical analysis showed the significant difference between the groups cured by plastic-wrapped and unwrapped LCU. Then, the use of plastic-wrapped LCU influences the diametral tensile strength of composite resin."
Jakarta: Fakultas Kedokteran Gigi Universitas Indonesia, 2013
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Marcella Lydia
"Latar Belakang: Resin komposit Giomer Bulk-Fill merupakan resin komposit yang dapat ditumpat hingga ketebalan 4 mm dan dapat melepas ion fluor. Resin komposit ini juga menjadi buffer asam ketika tingkat pH saliva turun dan mengembalikan ke pH netral. Namun, kenaikan pH diikuti dengan penurunan sifat fisik dari material. Belum diketahui apakah terdapat pengaruh terhadap kekerasan permukaan setelah material ini melepas fluor dan perubahan pH saliva.
Tujuan: Untuk mengetahui pengaruh perbedaan pH saliva buatan dan lama perendaman terhadap kekerasan permukaan resin komposit Giomer Bulk-Fill.
Metode: Penelitian eksperimental laboratorik menggunakan sembilan puluh spesimen resin komposit Giomer Bulk-Fill berdiameter 6 mm dan tinggi 3 mm dibagi menjadi 9 kelompok perendaman yaitu dengan saliva buatan pH 7 (kontrol); pH 5,5; pH 4,5 dengan lama perendaman 1 jam, 24 jam, dan 72 jam yang disimpan dalam inkubator dengan suhu 37°C. Uji kekerasan menggunakan Knoop Microhardness Tester (Shimadzu HMV-G21DT, Jepang).
Hasil: Berdasarkan hasil uji statistik One-way ANOVA terdapat perbedaan bermakna (p<0,05) antara kelompok perendaman dalam saliva buatan pH 4,5 dengan kelompok perendaman dalam saliva buatan pH 5,5 dan kelompok perendaman dalam saliva buatan pH 4,5 dengan kelompok perendaman dalam saliva buatan pH 7 yang dilakukan perendaman selama 72 jam. Nilai kekerasan pada perendaman dengan saliva buatan pH 4,5 dan lama perendaman 1 jam, 24 jam, dan 72 jam beruturut-turut sebesar 35,9±2,40 KHN, 33,75±2,98 KHN, dan 32,7±2,71 KHN. Sementara itu, nilai kekerasan dengan saliva buatan pH 5,5 dan lama perendaman 1 jam, 24 jam, dan 72 jam beruturt-turut sebesar 38,92±2,96 KHN, 37,00±1,82 KHN, dan 38,6±3,42 KHN. Dengan larutan saliva buatan pH 7 dan lama perendaman 1 jam, 24 jam, dan 72 jam didapatkan nilai kekerasan berturut-turut adalah 37,01±2,21 KHN, 37,05±1,79 KHN dan 37,72±2,51 KHN.
Kesimpulan: Lama perendaman dan tingkat keasaman dalam saliva buatan dapat menurunkan nilai kekerasan permukaan resin komposit Giomer Bulk-Fill.

Introduction: Composite resin Giomer Bulk-Fill is a material for restoration that can be placed in single increment with depth until 4 mm and release fluoride ion. This composite resin can be an acidic buffer when pH saliva drops and turns it back to pH neutral. However, the physical properties of the material are decreased. It is unknown if there any change of surface hardness of the material due to fluoride ion release and changes in pH saliva.
Objective: This study aimed to determine the effect of immersion time and different pH levels of artificial saliva on surface microhardness of composite resin Giomer Bulk-Fill.
Methods: Laboratory experimental research using ninety specimens of resin composite Giomer Bulk-Fill and divided into nine groups with immersion in artificial saliva pH 7 (control); 5,5; and 4,5 for 1, 24, and 72 hours at 37°C respectively and tested using Knoop Microhardness Tester (Shimadzu HMV-G21DT, Japan).
Result: The statistical test using One-way ANOVA showed that there were significant differences (p<0,05) between group of immersion in artificial saliva pH 4,5 compared to group of immersion in artificial saliva pH 5,5 and group of immersion in artificial saliva pH 5,5 compared to group of immersion in artificial saliva pH 7 for 72 hours of immersion. The result showed that the hardness number of the groups immersed in artificial saliva pH 4,5 for 1 hour, 24 hours, and 72 hours respectively are 35,9±2,40 KHN, 33,75±2,98 KHN, and 32,7±2,71 KHN. Meanwhile, the hardness number of the groups immersed in artificial saliva pH 5,5 for 1 hour, 24 hours, and 72 hours respectively 38,92±2,96 KHN, 37,00±1,82 KHN, and 38,6±3,42 KHN. The hardness number of the groups immersed in aritificial saliva of pH 7 for 1 hours, 24 hours, and 72 hours are 37,01±2,21 KHN, 37,05±1,79 KHN dan 37,72±2,51 KHN.
Conclusion: Different immersion times and pH levels decrease surface microhardness of Giomer Bulk-Fill composite resin.
"
Jakarta: Fakultas Kedokteran Gigi Universitas Indonesia, 2018
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Rebecca Grace Agustina
"Penelitian ini bertujuan untuk mengevaluasi pengaruh durasi penyinaran terhadap kekuatan tarik diametral resin komposit bulk-fill. Enam puluh spesimen Tetric N-Ceram Bulk-Fill ketebalan 3 mm dan diameter 6 mm; warna IVA dan IVW dibagi ke dalam 3 kelompok berdasarkan durasi penyinaran 10 detik, 15 detik, dan 20 detik untuk setiap warna. Spesimen dipolimerisasi dengan LED curing unit Bluephase Style, 1.280 mW/cm2 dan diuji kekuatan tarik diametralnya menggunakan uji statistik Universal Testing Machine. Data yang diperoleh dianalisis menggunakan One-Way ANOVA dan Post-Hoc Tukey HSD. Hasil menunjukkan adanya perbedaan bermakna.

This study was conducted to evaluate the influence of different exposure time and bulk fill composite shade on its diametral tensile strength. Sixty disc shaped specimens of Tetric N Ceram Bulk Fill 3 mm of thickness x 6 mm of diameter shade IVA and IVW were divided into 3 subgroups for each shade according to exposure times 10 s, 15 s, and 20 s . All specimens were polymerized using LED curing unit Bluephase Style, 1.280 mW cm2 and tested using Universal Testing Machine to determine its diametral tensile strength. Data were statistically analyzed using One Way ANOVA dan Post Hoc Tukey test. The result showed a significant differences in all groups."
Jakarta: Fakultas Kedokteran Gigi Universitas Indonesia, 2016
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
<<   1 2 3 4 5 6 7 8 9 10   >>