Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 176584 dokumen yang sesuai dengan query
cover
Uly Amrina
"Sektor pengelolaan limbah domestik menghasilkan emisi GRK dalam jumlah signifikan. Pengelolaan air limbah di Indonesia didominasi dengan sistem on-site, akan tetapi minimnya studi mengenai emisi GRK dari kegiatan pengelolaan limbah pada sistem on-site. Sehingga pemilihan sistem pengolahan air limbah menentukan besarnya emisi yang dihasilkan seperti metana (CH4), karbon dioksida (CO2) dan dinitrogen oksida (N2O).
Tujuan dari penelitian ini adalah untuk menganalisa dan memproyeksi emisi gas rumah kaca dari skenario BAU dan tiga alternatif skenario dari kegiatan pengelolaan air limbah dengan sistem setempat (on-site) di Kota Depok periode 2017-2040, serta merekomendasikan skenario terbaik dan alternatif strategi untuk mencapai target skenario tersebut dengan analisa SWOT. Ruang lingkup yang dihitung meliputi proses pengolahan air limbah domestik, proses pengolahan lumpur, konsumsi bahan bakar untuk pengumpulan lumpur, dan kegiatan konsumsi listrik untuk operasional IPLT dengan menggunakan metode IPCC (2006) dan faktor emisi. Data didapatkan dari kegiatan operasional IPLT, wawancara dengan pihak terkait, dan juga data masterplan Kota Depok.
Total emisi yang dihasilkan pada tahun 2017 sebesar 232,45 Gg CO2eq, yang terdiri atas 232,39 Gg CO2eq emisi langsung dan 0,0662 Gg CO2eq emisi tidak langsung. Emisi tersebut meningkat sebesar 70,51% di tahun 2040 berdasarkan kondisi BAU. Studi ini menunjukan bahwa skenario ketiga merupakan skenario terbaik dalam usaha penurunan emisi GRK, dimana penurunan mencapai 50,34% di tahun 2040 dari kondisi BAU, dengan intervensi berupa pemanfaatan biogas pada IPAL Komunal dan unit anaerobic digester di IPLT.

The biggest source of liquid waste is from household activities, so that good management of wastewater is very important so it does not cause problems for the environment or public health. Good management of wastewater also needs to take into account the emissions generated from the treatment. The selection of a wastewater treatment system determines the amount of emissions produced such as methane (CH4), carbon dioxide (CO2) and nitrous oxide (N2O).
The purpose of this study is to analyze and project greenhouse gas emissions from the BAU scenario and three alternative scenarios from on-site wastewater management activities in Depok City for the 2017-2040 period, and recommend the best scenarios and alternative strategies to achieve the target scenario is a SWOT analysis. Emission levels are calculated from domestic wastewater treatment processes, sludge treatment processes, fuel consumption for mud collection, and electricity consumption activities for the IPLT operation using the IPCC method in 2006.
Total emissions generated in 2017 amounted to 232.45 Gg CO2eq, which consists of 232.39 Gg of direct emissions CO2eq and 0.0662 Gg of indirect emissions CO2eq. These emissions increased by 70.51% in 2040 based on BAU conditions. This study shows that the third scenario is the best scenario in reducing GHG emissions, where the decline reached 50.34% in 2040 from BAU conditions, with interventions in the form of biogas utilization in Communal WWTPs and anaerobic digester units in the IPLT.
"
Depok: Fakultas Teknik Universitas Indonesia, 2019
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
"Air merupakan salah satu komponen terpenting dalam hidup ini. Semakin bertambahnya jumlah penduduk, kebutuhan terhadap air cenderung menngalami peningkatan, baik untuk air minum, kebutuhan rumah tangga, pertanian, energi, maupun industri. Tidak mengherankan jika saat ini para ahli yang bergerak dalam pengadaan air bersih, berusaha semaksimal mungkin mencari sumber-sumber air untuk memenuhi kebutuhan hidup manusia baik melalui pencarian sumber-sumber baru maupun pengolahan kembali air buangan.
Koagulasi merupakan salah satu proses pengolahan air dengan cara penambahan bahan kimia, yang tujuannya untuk mengikat pengotor (partikel maupun terlarut sehingga menggumpal). Beberapa koagulan yang dikenal dan digunakan oleh masyarakat pada umumnya adalah tawas (Aluminium Sulfat), PAC (Poly Aluminium Chlorida), dan copperas (Fero Sulfat). Koagulan adalah suatu bahan kimia yang bereaksi dengan air untuk membentuk presipitat bervolume besar yang disebut dengan istilah koagulasi (penggumpalan). Metoda penelitian dilakukan cukup sederhana yaitu; menggunakan botol dengan kapasitas 10.6 L dengan diameter 76 cm dan ketinggiannya 27 cm. Air baku yang diolah berasal dari air buangan rumah tangga di lingkungan kampus Universitas Jenderal Achmad Yani.
Hasil penelitian menunjukkan bahwa PAC adalah koagulan yang mempunyai efektifitas yang lebih tinggi, dapat menurunkan kesadahan sampai dengan 51,59%, tawas dapat menurunkan kesadahan 42,23% dan copperas 33,27% pada dosis yang sama 30 ppm. Pengadukan dapat mempengaruhi proses koagulasi."
KWK 17:1 (2009)
Artikel Jurnal  Universitas Indonesia Library
cover
Reed, Sherwood C.
New York: McGraw-Hill, 1988
628.4 REE n
Buku Teks  Universitas Indonesia Library
cover
Bagus Arifianto Sasono
"Sejalan dengan Rencana Aksi Nasional Penurunan Emisi Gas Rumah Kaca dari pemerintah Indonesia, buruknya pengelolaan sampah dan air limbah di Universitas Indonesia UI dan peran universitas sebagai agen perubahan, maka buruknya sektor pengelolaan sampah dan air limbah di UI membutuhkan perhatian lebih dari pihak pengelola universitas. Dengan timbulan sampah UI pada pertengahan tahun 2018 mencapai angka 17,25 ton/hari dimana 13 ton sampah tersebut tidak diolah dan langsung diangkut menuju ke TPA. Debit air limbah di UI juga mencapai 7.260 m3/hari dimana pengelolaannya didominasi dengan tangki septik dan pembuangan langsung ke danau.
Penelitian ini bertujuan untuk mengestimasi tingkat emisi GRK dan Non-GRK dari pengelolaan eksisting dan melakukan pengembangan skenario guna menurunkan emisi yang ada. Estimasi emisi GRK dan Non-GRK akan menggunakan metode dari IPCC, NPI, EPA dan faktor emisi dari penelitian-penelitian sebelumnya. Berdasarkan hasil estimasi skenario eksisting, sektor pengelolaan sampah mengemisikan 5,5 juta kgCO2eq/tahun dan 3.859 kgVOCs/tahun serta pengelolaan air limbah mengemisikan 411 ribu kgCO2eq/tahun.
Dari hasil analisis dan pengembangan skenario, pada pengelolaan sampah direkomendasikan perubahan alur penanganan sampah dimana tingkat recycling ditingkatkan, open dumping dan open burning dihilangkan, komposting ditingkatkan, pengiriman sampah ke kawasan industri sehingga sampah menuju landfill berkurang. Ini dapat membuat emisi GRK berkurang sebesar 38 dan VOCs berkurang >60 menjadi 3,4 juta kg CO2eq/tahun dan1.560 kgVOCs/tahun.
Rekomendasi pengelolaan air limbah di semua gedung adalah dengan menggunaka sewage treatment plant dan untuk kantin menggunakan wetlands jenis vertical sub surface flow. Hasilnya pengurangan emisi sebesar 17 dapat dicapai menjadi 341 ribu kgCO2eq/tahun. Sehingga secara keseluruhan, di sektor pengelolaan limbah emisi dapat berkurang sebesar 37.

In line with the National Action Plan for Greenhouse Gas Emission Reduction from the Indonesian government, bad solid waste and waste management at the University of Indonesia UI and the role of universities as agents of change, the bad solid waste and wastewater management sector in UI requires more attention from the university management. With the generation of waste UI in the middle of 2018 reached the number 17.25 tons day where 13 tons of waste is not processed and directly transported to the landfill. The waste water discharge in UI also reaches 7,260 m3 day where its management is dominated by septic tank and disposal directly to the lake.
This study aims to estimate GHG emission levels and non GHG emissions from existing management and develop scenarios to reduce emissions. GHG and Non GHG emissions estimates will use methods from IPCC, NPI, EPA and emission factors from previous studies. Based on the estimation of the existing scenario, the waste management sector emits 5.5 million kgCO2eq year and 3,859 kgVOCs year and also wastewater management emits 411 thousand kgCO2eq year.
From the analysis and scenario development, solid waste management is recommended to change the flow of waste management where the level of recycling is improved, open dumping and open burning are eliminated, the composting is improved, the garbage delivery to the industrial area so that the waste into the landfill is reduced. This can make GHG emissions decrease by 38 and VOCs decrease 60 to 3.4 million kg CO2eq year and 1,560 kgVOCs year.
Recommendation of wastewater management in all buildings is by using sewage treatment plant and for cafetaria using wetlands type of vertical sub surface flow. The result of emissions reductions of 17 can be achieved to 341 thousand kgCO2eq year . So overall, in the emissions management sector emissions could be reduced by 37.
"
Depok: Fakultas Teknik Universitas Indonesia, 2018
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Marpaung, Risha Meilinda
"Di antara semua limbah medis, limbah cair merupakan ancaman serius bagi kesehatan manusia dan lingkungan karena kemampuannya memasuki daerah aliran sungai, mencemari air tanah, dan air minum jika tidak ditangani dan dibuang dengan benar. Efektivitas pengelolaan limbah cair dan kualitas limbah cair masih menjadi masalah yang signifikan di fasilitas pelayanan kesehatan di Indonesia, dimana limbah cair masih banyak yang tidak memenuhi standar baku mutu. Penelitian ini bertujuan untuk menganalisis manajemen pengelolaan limbah cair, efektivitas IPAL, kualitas limbah cair, dan strategi pengelolaan permasalahan efektivitas IPAL Rumah Sakit Swasta X Depok. Penelitian ini menggunakan metode mixed methods (kuantitatif deskriptif dengan desain studi kasus dan kualitatif dengan triangulasi konkuren dan analisis SWOT). Penelitian ini berlangsung dari Desember - April 2023 dengan menggunakan data sekunder periode Juli 2021 - Juni 2022. Standar regulasi yang dijadikan acuan dalam penelitian ini adalah Peraturan Menteri Lingkungan Hidup dan Kehutanan Republik Indonesia Nomor: P.68/Menlhk/Setjen/Kum. 1/8/2016 tentang Baku Mutu Limbah Cair Domestik. Analisis data dilakukan dengan analisis kuantitatif (analisis univariat), analisis kualitatif, dan analisis SWOT. Manajemen pengelolaan limbah cair di Rumah Sakit Swasta X Depok dapat terlihat dari aspek peraturan, kebijakan, dan perundang-undangan; aspek proses pengelolaan limbah cair; dan aspek monitoring dan evaluasi sudah sesuai dengan Permenkes Nomor 7 Tahun 2019. Namun, aspek sumber daya manusia, sarana prasarana, dan dana belum sepenuhnya sesuai dengan Permenkes Nomor 7 Tahun 2019. Kualitas limbah cair (fisika, kimia, biologi) di bagian inlet dan outlet IPAL Rumah Sakit Swasta X Depok pada bulan Juli 2021 - Juni 2022 masih berfluktuasi. Efektivitas IPAL Rumah Sakit Swasta X Depok masih fluktuatif pada periode bulan Juli 2021 - Juni 2022. Strategi pengelolaan permasalahan efektivitas IPAL Rumah Sakit Swasta X Depok berdasarkan analisis SWOT yang telah dilakukan, yakni strategi agresif. dengan lima rekomendasi inovatif untuk meningkatkan manajemen peningkatan efektivitas IPAL. Rumah Sakit Swasta X Depok dapat memastikan sumber limbah cair, menambahkan bak penampung sementara, memberikan pretreatment pada limbah cair, pemeriksaan hasil influen limbah cair setiap bulan, menyiapkan cadangan blower, pompa celup, saringan pasir lambat, serta menambahkan bak netralizing, alat pengukur klor, alat pengukur tekanan oksigen, sinar ultraviolet pada IPAL, komponen swapantau harian agar dapat meningkatkan efektivitas IPAL dalam menurunkan parameter pencemar limbah cair.

Among all medical wastes, wastewater poses a serious threat to human health and the environment due to its ability to enter watersheds, contaminate groundwater and drinking water if not handled and disposed of properly. The effectiveness of liquid waste management and the quality of liquid waste are still significant problems in health care facilities in Indonesia, where there are still many liquid wastes that do not meet quality standards. This study aims to analyze the management of liquid waste management, the effectiveness of the WWTP, the quality of the liquid waste, and strategies for managing the problem of the effectiveness of the IPAL of Private Hospital X Depok. This research uses mixed methods (quantitative descriptive with case study design and qualitative with concurrent triangulation and SWOT analysis). This research took place from March - April 2023 using secondary data for the period July 2021 - June 2022. The regulatory standard used as a reference in this research is the Regulation of the Minister of Environment and Forestry of the Republic of Indonesia Number: P.68/Menlhk/Setjen/Kum. 1/8/2016 concerning Domestic Liquid Waste Quality Standards. Data analysis was performed by quantitative analysis (univariate analysis), qualitative analysis, and SWOT analysis. The management of liquid waste management at X Private Hospital Depok can be seen from the aspects of regulations, policies and legislation; aspects of the liquid waste management process; and monitoring and evaluation aspects are in accordance with Permenkes Number 7 of 2019. However, aspects of human resources, infrastructure, and funds are not fully in accordance with Permenkes Number 7 of 2019. The quality of wastewater (physics, chemistry, biology) in the inlet and IPAL outlets at Private Hospital X Depok in July 2021 - June 2022 are still fluctuating. The effectiveness of WWTP for Private Hospital X Depok is still fluctuating in the period July 2021 - June 2022. The strategy for managing the problem of IPAL effectiveness for Private Hospital X Depok is based on the SWOT analysis that has been carried out, namely an aggressive strategy with five innovative recommendations to improve management to increase the effectiveness of WWTP. Private Hospital X Depok can ensure the source of liquid waste, add temporary storage tanks, provide pretreatment of liquid waste, check the results of influent liquid waste every month, prepare backup blowers, submersible pumps, slow sand filters, and add neutralizing tanks, chlorine gauges, oxygen pressure gauges, ultraviolet rays in the WWTP, daily self-monitoring components in order to increase the effectiveness of the WWTP in reducing liquid waste pollutant parameters."
Depok: Fakultas Kesehatan Masyarakat Universitas Indonesia, 2023
T-pdf
UI - Tesis Membership  Universitas Indonesia Library
cover
Noni Chrissuda Anggraini
"Hasil pemeriksaan limbah cair yang dilakukan pada bulan Agustus tahun 2016, titik inlet dan outlet menunjukan kesenjangan hasil dimana hasil pemeriksaan di titik outlet lebih besar dari pada titik inlet untuk parameter TDS, TSS, pH, COD dan MBAS. Tujuan dari penelitian ini adalah menganalisi efektifitas pengolahan limbah cair di Rumah Sakit Harapan Depok memenuhi baku mutu limbah cair tahun 2017. Dengan penelitian ini bersifat studi kasus.
Sumber penghasil Limbah cair Rumah Sakit Harapan Depok terbesar berasal dari seluruh aktifitas kegiatan di rumah sakit, jenis dan sumber terbesar air limbah yang dihasilkan di Rumah Sakit adalah limbah domestik, sisanya limbah yang terkontaminasi oleh infection agents kultur mikroorganisme, darah, buangan pasien pengidap penyakit infeksi, dan lain-lain. Debit output limbah cair rata-rata yang dihasilkan 3 m3/hari. Jaringan perpiaan yang digunakan sebagian terbuat dari pipa PVC sebagian terbuat dari beton yang masih terbuka. Proses pengolahan limbah cair di Rumah Sakit Harapan Depok melalui 3 proses pengolahan yaitu pengolahan pendahuluan pre treatment, pengolahan pertama primary treatment, pengolahan kedua secondary treatment, pengolahan ketiga tertiary treatment.
Berdasarkan perhitungan waktu tinggal diperoleh hasil yang belum efektif yaitu pada bak equalisasi didapatakan hasil 35,87 jam dengan kedalam bak ekualisasi 1,5 m. Pada bak sedimentasi belum efektif dalam menurunan kadar pencemar yaitu BOD 0,49 dan TSS 0,95 dengan waktu tinggal 41,6 jam. Kualitas inffluent dan effluent limbah cair dari hasil pemeriksaan sudah efektif dalam menurunkan beban pencemaran limbah cair sesuai dengan baku mutu yang dipersyarat KepMen LH RI No. 5 tahun 2014 tentang Baku Mutu Air Limbah Bagi Usaha dan/atau Kegiatan Fasilitas Pelayanan Kesehatan.

The results of the wastewater tests conducted in August 2016, the inlet and outlet sampling points indicate the results gap in which the checkout results at the outlet point is greater than the inlet point for TDS, TSS, pH, COD and MBAS parameters.This research aims to analyze effectivity of wastewater treatment plan at Harapan Depok Hospital fulfill wastewater quality standard in 2017. With this research is case study.
The largest source of wastewater from Harapan Depok Hospital comes from all activities in the hospital, the type and largest source of wastewater produced in the hospital is domestic waste, the rest of the waste contaminated by the infection agents culture of microorganisms, blood, diseases of patients with infectious diseases, and others. The average liquid waste discharge output produced 3 m3 day. The partial used network made of PVC pipe is partly made of open concrete. Wastewater treatment process at Harapan Hospital Depok through 3 processing process that is pre treatment, primary treatment, secondary treatment, tertiary treatment.
Based on the calculation of residence time obtained results that have not been effective in equalization obtained results 35.87 hours with 1.5 m in equalization basin. In the sedimentation has not been effective in decreasing levels of pollutants ie BOD 0.49 and TSS 0.95 with a residence time of 41.6 hours. The quality of inffluent and effluent of wastewater from the result of inspection has been effective in decreasing the burden of pollution of wastewater in accordance with the quality standard which is signed by Minister of Environment Decree of the Republic of Indonesia number 5 2014 on Quality Standard of Waste Water for Business and or Activity of Health Service Facility.
"
Depok: Fakultas Kesehatan Masyarakat Universitas Indonesia, 2017
S69171
UI - Skripsi Membership  Universitas Indonesia Library
cover
"Methods of treatment in which the application of physical forces are known as operation units. Methods of treatment in which the removal of contaminants which is brought by chemical or biological processes are known as unit processes. At the present time, unit operations and processes are grouped together to provide what is known as primary, secondary and tertiary treatment.
In primary treatment, physical operations such as screebing and sedimentation are used to remove the floating and settleable solids from the wastewater. In secondary treatment, chemical and biological processes are used to remove most of organics matter. In tertiary treatment, the combination of unit operations and processes are used to remove other constituents, such as nitrogen and phoshphorus, which are not removed by secondary treatment.
The hospital's wastewater has a specific characteristic that is the infectious wastewater. The phosphorus contain in Sleman's Public Hospital wastewater is larger than the maximum standard, so it need tertiary treatment adding on the Sleman's Public Hospital wastewater plant treatment. "
MTUGM 30:4 (2008)
Artikel Jurnal  Universitas Indonesia Library
cover
Kara Carolluna
"

Peningkatan efisiensi penggunaan air secara signifikan dan meminimalkan pelepasan polutan dan bahan kimia yang berbahaya merupakan salah satu agenda tiap negara yang perlu dicapai pada 2030. Air limbah domestik dengan fosfat yang berlebih membuat kadar oksigen terlarut berkurang dan terciptanya kondisi anoksik pada badan air karena eutrofikasi. Penelitian ini ditujukan untuk menganalisis proses dan kondisi optimum presipitasi fosfat pada air limbah domestik dengan menggunakan kalsium dari abu lumpur aktif pada keadaan ideal serta memperoleh nilai koefisien laju reaksinya. Variasi konsentrasi optimum diperoleh dari analisis Visual-MINTEQ dengan memasukan data tipikal kalsium, fosfat, pH, dan suhu. Analisis presipitasi reaktor batch dengan variasi konsentrasi kalsium abu lumpur aktif pada skala laboratorium dilakukan dalam mengidentifikasi konsentrasi pengurangan fosfat dengan metode spektrofotometri menggunakan spektrofotometer DR2000. Sebanyak 30,86% komponen anorganik lumpur aktif dan 5450,6 mg/kg abu lumpur aktif yang menjadi karakteristik sampel lumpur aktif yang digunakan. Data laboratorium menunjukkan bahwa penyisihan fosfat optimum pada air limbah dengan pH 6,8 yang mengandung 7,79 mg TP/L dibutuhkan 70 mg/L kalsium abu lumpur aktif atau setara dengan 6,4 gram abu lumpur aktif. Intervensi kandungan organik, senyawa ligan, zat tersuspensi (TSS), karbonat, dan logam, seperti Al (81700 mg/kg) dan Fe (65500 mg/kg) berdampak pada pengikatan fosfat oleh kalsium karena faktor produk reaksi dan pH yang dapat mengurangi pembetukan Ca-P. Permodelan reaksi memperoleh koefisien laju reaksi terbesar pada reaktor dengan kalsium paling banyak (k = 0,00692/menit) yang dilakukan pada 2 reaktor seri sebagai desain paling efisien. Hasil eksperimen menunjukkan bahwa semakin tinggi konsentrasi kalsium abu lumpur aktif, semakin besar penyisihan fosfat dan koefisien laju reaksinya dengan mempertimbangkan intervensi dari kandungan organik, TSS, senyawa ligan air limbah domestik serta kandungan logam pada abu lumpur aktif.


Significantly increasing the efficiency of water use and minimizing the release of harmful pollutants and chemicals is one of the agendas of each country that needs to be achieved by 2030. Domestic wastewater with excess phosphate reduces dissolved oxygen levels and creates anoxic conditions in water bodies due to eutrophication. This study aims to analyze the process and optimum conditions for phosphate precipitation in municipal wastewater using calcium from activated sludge ash under ideal conditions and obtain the value of the reaction rate coefficient. Optimum concentration variations were obtained from Visual-MINTEQ analysis by entering data on typical calcium, phosphate, pH, and temperature. Batch reactor precipitation analysis with varying concentrations of activated sludge calcium ash on a laboratory scale was carried out in identifying the concentration of phosphate reduction by spectrophotometric method using a DR2000 spectrophotometer. As much as 30.86% of the inorganic component of activated sludge and 5450.6 mg/kg of activated sludge ash which is characteristic of the activated sludge samples used. Laboratory data shows that the optimum phosphate removal in wastewater with a pH of 6.8 containing 7.79 mg TP/L requires 70 mg/L calcium activated sludge or equivalent to 6.4 grams of activated sludge ash. Intervention of organic compounds, ligand compounds, suspended matter (TSS), carbonates, and metals, such as Al (81700 mg/kg) and Fe (65500 mg/kg) has an impact on the binding of phosphate by calcium due to reaction product factors and pH which can reduce the formation of Stamp. The reaction modeling obtained the largest reaction rate coefficient in the reactor with the most calcium (k = 0.00692/minute) which was carried out in 2 series reactors as the most efficient design. The experimental results show that the higher the calcium concentration of activated sludge ash, the greater the phosphate removal and the reaction rate coefficient by considering the intervention of organic content, TSS, domestic wastewater ligand compounds and metal content in activated sludge ash.

"
Depok: Fakultas Teknik Universitas Indonesia, 2023
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Devi Dwiyanti Suryono
"Limbah domestik merupakan salah satu pencemar yang sangat berpotensi untuk menimbulkan pencemaran lingkungan, terutama limbah domestik yang berasal dari tangki septik. Beberapa penelitian menunjukkan bahwa kota-kota besar di Indonesia sudah tercemar oleh buangan toilet (black Water), yang diperkirakan 70-80% dari limbah ini langsung mencemari air tanah dangkal.
Berdasarkan kenyataan tersebut kebutuhan fasilitas pengolahan limbah tangki septik harus diperhatikan, karena kualitas efluen hasil pengolahan di dalam tangki septik ternyata masih berpotensi untuk mencemari lingkungan. Oleh karena itu, diperlukan suatu alternatif penyelesaian untuk memperbaiki kualitas efluen limbah tangki septik.
Penelitian pengaruh bahan starter terhadap efektivitas pengolahan limbah tangki septik ini dilakukan sebagai alternatif untuk menyelesaikan masalah pengolahan limbah tangki septik. Dengan penambahan bahan starter, berarti ada penambahan sejumlah mikroorganisme ke dalam sistem pengolahan limbah tangki septik yang bertujuan untuk meningkatkan efektivitas pengolahannya.
Tujuan penelitian ini adalah untuk mengetahui pengaruh bahan starter M-Bio dan isi rumen terhadap efektivitas penurunan kadar parameter COD, PO43-, N03-, N02-, padatan tersuspensi, dan E. coli, serta untuk membandingkan pengaruh kedua bahan starter tersebut dalam berbagai variasi dosis.
Hipotesis yang diajukan dalam penelitian ini adalah:
1. Penambahan bahan starter M-Bio dapat meningkatkan efektivitas pengolahan limbah tangki septik terhadap parameter COD, P043- N03-, N02-, padatan tersuspensi, dan E. coli,
2. Penambahan bahan starter isi rumen dapat meningkatkan efektivitas pengolahan limbah tangki septik terhadap parameter COD, PO43-, N03-, N02-, padatan tersuspensi, dan E. coli.
Penelitian eksperimental dilakukan dalam skala laboratorium dengan rancangan penelitian acak lengkap yang disusun secara faktorial, yang dilakukan di Laboratorium Lingkungan, FTUI. Pengamatan dilakukan dengan interval waktu pengamatan 8 jam, yaitu 0, 8, 16, 24, 32, 40, dan 48 jam, serta pengamatan dilakukan hingga 72 dan 96 jam. Variasi dosis bahan starter,yakni M-Bio dan isi rumen adalah 2,5 ml/L, 5 ml/L, dan 7,5 ml/L, kemudian setiap pengamatan dibandingkan terhadap kontrol. Sampel limbah tangki septik diambil dari asrama mahasiswa UI, Depok. Parameter utama yang diukur adalah COD, PO43-, N03-, N02-, padatan tersuspensi, dan E. coli. Data hasil pengamatan dianalisis menggunakan uji statistik ANOVA, dan rumus kinetika reaksi biokimia M-Bio dan isi rumen.
Berdasarkan hasil penelitian ternyata bahan starter M-Bio meningkatkan efektivitas pengolahan limbah tangki septik yang ditunjukkan dengan penurunan bermakna terhadap konsentrasi parameter COD, PO43-, N03-, N02-, padatan tersuspensi, dan E. coli. Sedangkan bahan starter isi rumen tidak dapat meningkatkan efektivitas pengolahan limbah tangki septik terhadap parameter COD, PO43-, N03-, NO2-, padatan tersuspensi, bahan starter isi rumen hanya dapat meningkatkan efektivitas penurunan parameter E. coli.
Perhitungan konstanta kinetika reaksi biokimia M-Bio menghasilkan laju penguraian bahan organik (rsu) antara 6,7552-90,4693 mg/L/jam, dan pertumbuhan bersih mikroorganisme antara 0,0852-0,4011 sel/jam. Sedangkan, perhitungan konstanta kinetika reaksi biokimia isi rumen menghasilkan laju penguraian bahan organik (rsu) antara 1,6735-10,6951 mg/L/jam, dan pertumbuhan bersih mikroorganisme antara 0,0078-0,0852 sel/jam.
Kesimpulan dari penelitian ini adalah:
1. Penambahan bahan starter M-Bio dapat meningkatkan efektivitas pengolahan limbah tangki septik yang ditunjukkan oleh penurunan terhadap konsentrasi parameter COD, P043-, N03-, N02-, padatan tersuspensi, dan E. coli.
2. Penambahan bahan starter M-Bio memberikan tingkat efisiensi penurunan konsentrasi parameter COD sebesar 83,06%, P043- sebesar 86,76%, N03- sebesar 65,14%, N02- sebesar 73,40%, padatan tersuspensi sebesar 71,15%, dan E. coli sebesar 83,78%.
3. Penambahan bahan starter M-Bio pada dosis 5 ml/L menunjukkan tingkat penurunan yang paling tinggi dibandingkan dosis lainnya pada parameter COD, P043-, N03-, N02-, dan padatan tersuspensi, sedangkan tingkat penurunan parameter E. coli yang paling tinggi ditunjukkan oleh bahan starter M-Bio dosis 7,5 ml/L.
4. Penambahan bahan starter isi rumen tidak dapat meningkatkan efektivitas pengolahan limbah tangki septik terhadap konsentrasi parameter COD, P043-, N03-, NO2-, padatan tersuspensi, tetapi hanya efektif untuk menurunkan jumlah E. coli.
5. Laju Pertumbuhan bersih mikroorganisme (µ) dan laju penguraian substrat (rsu) pada pengolahan limbah tangki septik dengan dosis 5 ml/L adalah µ = 0,4011/jam dan rsu = 90,4693 mg/L/jam.

Starter Influence on Domestic Wastewater Treatment Affectivity (A Case Study on Septic Tank Wastewater of Indonesia University Dormitory, Depok) Domestic wastewater is one of the pollutants that caused environmental pollution, especially septic tank wastewater. The surveys show that some of city of Indonesia has been polluted by septic tank wastewater (black water), that estimated 70-80% polluted directly the ground water.
Based on this condition, the necessity of septic tank wastewater treatment facility should be attended, because the effluent quality as result of a treatment in septic tank still have chance to pollute the environment. So that, the solving alternative is needed to make septic tank wastewater effluent quality better. This research about starter influence on septic tank wastewater treatment affectivity was conducted as an alternative to solve septic tank wastewater treatment problem. By the starter addition, it means there are a number of microorganisms were added into septic tank wastewater treatment system to increase that treatment affectivity.
The aim of this research is to understand the starter influence of M-Bio and paunch manure on removal affectivity of parameters COD, P043 N03, N02-, suspended solid, and E. coil, and to compare the various dose of both of starter influence.
The hypotheses of this research are:
1. The addition of M-Bio starter increase the treatment affectivity of septic tank wastewater on parameters COD, P043-, N03-, N02-, suspended solid, and E. coli
2. The addition of paunch manure starter increase the treatment affectivity of septic tank waste on parameters COD, PO43-, N03-, N02-, suspended solid, and E coli.
The experimental study with factorial testing used complete random design and was conducted in the Environmental Laboratory of Engineering, University of Indonesia. The experiment was conducted with interval time of observation 8 hours, that is 0, 8,16, 24, 32, 40, and 48 hours, and the observation was still conducted until 72 and 96 hours. The various dose of both of starter, that is M-Bio and paunch manure is 2,5 ml/L, 5 ml/L, and 7,5 ml/L, and then each observation was compared with control. Septic tank waste samples were taken from Indonesia University dormitory, Depok. The main parameters that were measured were COD, P043-, N03-, N02-, suspended solid, and E. coli. The data were analyzed using analysis of variance (ANOVA) and standard formula to find kinetic constants of M-Bio and paunch manure biochemical reactions.
The final result of both of starter influenced indicate, that M-Bio starter increase the affectivity of septic tank wastewater treatment on parameters COD, PO43-, NO3-, NO2-, suspended solid, and E. coli. While, paunch manure starter not increase the affectivity of septic tank wastewater treatment on parameters COD, PO43-, NO3-, NO2-, suspended solid, paunch manure starter just can increase parameters E. coli. The calculation for kinetic constant of M-Bio biochemical reactions obtained the result that the rate of decomposition of organic material (rsu) was between 6,7552-90,4693 mg/L/hour, and the net growth rate of microorganism was between 0,0852-0,4011 cells/hour. While, the calculation for kinetic constant of paunch manure biochemical reactions obtained the result that the rate of decomposition of organic material (rsu) was between 1,6735-10,6951 mg/L/hour, and the net growth rate of microorganism was between 0,0078-0,0852 cells/hour.
The conclusions of this study are:
1. M-Bio starter increase the affectivity of septic tank wastewater treatment on parameters COD, PO43-, N03-, NO2-, suspended solid, and E. coli.
2. The removal efficiency of COD result in 83,06%, PO43- = 86,76%, NO3- = 65,14%, N02- = 73,40%, suspended solid = 71,15%, and E. coli = 83,78%.
3. The most effective dose for parameters COD, PO43-, NO3-, NO2-, suspended solid is 5 ml/L. And, the most effective dose for parameter E. coli is 7,5 ml/L.
4. The addition of paunch manure starter can not increase the treatment affectivity of septic tank waste on parameters COD, PO43-, NO3-, NO2-, suspended solid, but paunch manure effectively increase on E. coli.
5. The rate of decomposition of organic material (r) for dose 5 ml/L is 90,4693 mg/L/hour, and the net growth rate of microorganism (µ) is 0,4011 cell/hours. While, The rate of decomposition of organic material (rsu) for dose 7,5 ml/L is 6,7552 mg/L/hour, and the net growth rate of microorganism (µ) is 0,1582 cells/hour."
2001
T7118
UI - Tesis Membership  Universitas Indonesia Library
cover
Retno Murti Wulandari
"Penggunaan koagulan tawas [Al2(SO4)3] dalam pengolahan air minum menghasilkan produk sampingan atau limbah berupa lumpur (lumpur alum). Lumpur alum yang tergolong limbah ini masih memiliki kemampuan untuk menghilangkan parameter pencemar seperti timbal (Pb) yang banyak terdapat di dalam air limbah misalnya air limbah industri aki. Penelitian ini dilakukan untuk mengetahui potensi pemanfaatan lumpur alum sebagai solusi alternatif dalam menurunkan konsentrasi Pb. Metode yang digunakan dalam penelitian ini adalah perbandingan penurunan konsentrasi timbal (Pb) antara penggunaan koagulan komersil tawas [Al2(SO4)3] dan lumpur alum dengan mempertimbangkan parameter warna, turbiditas, elektrokonduktivitas, TDS dan biaya. Pada percobaan ini, lumpur alum dipanaskan dalam oven pada 105°C selama 24 jam. Kemudian lumpur kering disaring dengan menggunakan saringan 100 ASTM untuk selanjutnya diujikan dengan metode jartest. Percobaan dilakukan dengan variasi pH, dosis koagulan, dan dosis lumpur berturut-turut pada rentang pH 2-10, 70-110 mg/l dan 5-25gr/l. Dari hasil analisis, antara percobaan lumpur alum dan koagulan komersil diperoleh persentase removal timbal (Pb) sebesar 99,37% dan 99,23% serta perbandingan biaya per liter air limbah sebesar Rp.1.381 dan Rp.1.578 dengan selisih biaya 14,42%. Sehingga disimpulkan bahwa penggunaan lumpur alum dapat menurunkan konsentrasi timbal secara efektif dan terjangkau secara biaya.

The utilization of aluminium sulfate Al2(SO4)3 as coagulant in water treatment plant generates by-product in the form of sludge. The sludge contains coagulant residual (alum sludge) which are toxic if disposed without proper treatment. Meanwhile, alum sludge which are classified as waste still has the capacity in removing pollutant in industrial waste water such as lead (Pb). Therefore, this study becomes important in order to analyse the potential use of alum sludge as an alternative solution to decrease the lead concentration in waste water. A comparative study between commercial coagulant aluminium sulfate [Al2(SO4)3] and alum sludge are used to compare the decrease of concentration lead (Pb) while considering the parameters of color, turbidity, electroconductivity, TDS and cost. In the experiment, the alum sludges were dried at 105°C for 24 hours. Then the dried alum sludge was ground and filtered using a 100 ASTM sieve to further tested by jartest method. The experiments were conducted by variating pH, coagulant dosage, and alum sludge dosage in the range of 2-10, 70-110 mg/l and 5-25 gr/l. Then the analysis shows a comparative result between alum sludge and commercial coagulant in lead metal removal rate as 99,37% and 99,23%, the cost for both comparation Rp.1.381 dan Rp.1.578 with capital margin 14,42%."
Depok: Fakultas Teknik Universitas Indonesia, 2013
S47559
UI - Skripsi Membership  Universitas Indonesia Library
<<   1 2 3 4 5 6 7 8 9 10   >>