Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 182662 dokumen yang sesuai dengan query
cover
Amirah Tri Ayudia
"Instalasi Pengolahan Lumpur Tinja (IPLT) merupakan pengolahan air limbah yang dirancang hanya menerima dan mengolah lumpur tinja yang berasal dari sistem setempat yang diangkut melalui sarana pengangkutan lumpur tinja. Lumpur tinja yang dihasil tersebut tentu harus diolah terlebih dahulu agar sesuai dengan baku mutu yaitu, Peraturan Menteri Lingkungan Hidup Nomor 68 Tahun 2016 Tentang Baku Mutu Air Limbah Domestik. Namun demikian, dalam proses pengolahan air limbah ini, tidak dapat dihindari kemungkinan terlepasnya pencemar udara mikrobiologis (bioaerosol) ke udara sekitar. Tujuan penelitian ini untuk mengetahui sumber pencemar, mengetahui total bakteri dan jamur di udara serta perbedaan konsentrasi bakteri dan jamur pada musim kemarau dan musim hujan, dan meninjau faktor lingkungan (suhu, kelembaban, dan Kecepatan angin) yang mempengaruhi konsentrasi. Penelitian ini dilakukan pada musim kemarau dan hujan dengan masing-masing lima hari pengambilan dan dilakukan di empat titik pada IPLT Kalimulya Depok (unit bak pengisian, digester anaerob, pemekat lumpur, dan biofilter aerob-anaerob). Dari hasil penelitian, rata-rata konsentrasi bakteri pada musim kemarau yaitu unit bak pengisian sebesar 243±265 CFU/m3, pemekat lumpur sebesar 155±326 CFU/m3, digester anaerob sebesar 154±157 CFU/m3, dan biofilter aerob anaerob sebesar 76±122 CFU/m3. Sedangkan pada musim hujan konsentrasi bakteri yaitu unit bak pengisian sebesar 33±24 CFU/m3, pemekat lumpur sebesar 25±62 CFU/m3, biofilter aerob-anaerob sebesar 21±20 CFU/m3, dan digester anaerob sebesar 16±13 CFU/m3. Kemudian pada musim kemarau, konsentrasi jamur pada pemekat lumpur sebesar 516±554 CFU/m3, unit bak pengisian sebesar 364±202 CFU/m3, digester anaerob sebesar 340±181 CFU/m3, dan biofilter aerob-anaerob sebesar 231±201 CFU/m3. Sedangkan pada musim hujan konsentrasi jamur pada unit bak pengisian sebesar 58±39 CFU/m3, pemekat lumpur sebesar 55±33 CFU/m3, digester anaerob sebesar, 36±32 CFU/m3, dan biofilter aerob-anaerob sebesar 32±23 CFU/m3. Sehingga, diketahui konsentrasi bakteri tertinggi ditemukan pada unit bak pengisian pada musim kemarau dan terendah pada digester anaerob pada musim hujan. Konsentrasi jamur tertinggi ditemukan di pemekat lumpur pada musim kemarau dan terendah pada biofilter aerob-anaerob pada musim hujan. Konsentrasi bakteri dan jamur berada dibawah standar baku mutu. Sedangkan korelasi antara faktor lingkungan terhadap konsentrasi bakteri dan jamur ditemukan di beberapa tempat dan terdapat juga perbedaan konsentrasi bakteri dan jamur pada musim kemarau dan musim hujan.

Sewage Treatment Plants (STPs) are wastewater processing systems that are designed to process only stool mud received from local systems of stool mud transport. The stool mud received must be processed so that it abides to the standard of quality according to the Regulation of the Minister of the Environment Number 68 Year 2016 concerning Domestic Wastewater Quality Standards. However, in the treatment process, there is a probability for a microbiological air pollutant (bioaerosol) to be produced that cannot be avoided. This research aims to analyze the source of pollution, the total amount of bacteria and fungi in the air, the difference of bacteria and fungi concentration between the dry and rainy season, and observe the environmental factors (temperature, humidity, wind speed) that affects bacteria and fungi concentration. This research was done during the dry and rainy season, each for a 5 day period in four observation points at the Kalimulya Depok STP (filling unit, anaerobic digester, mud concentrator and aerobic-anaerobic biofilter). The results of this research shows that the average bacteria concentration during the dry season is 243±265 CFU/m3 at the filling unit, 155±326 CFU/m3 at the mud concentrator, 154±157 CFU/m3 at the anaerobic digester, and 76±122 CFU/m3 at the aerobic-anaerobic biofilter. During the rainy season, the average bacteria concentration is 33±24 CFU/m3 at the filling unit, 25±62 CFU/m3 at the mud concentrator, 21±20 CFU/m3 at the aerobic-anaerobic biofilter, and 16±13 CFU/m3 at the anaerobic digester. The average fungi concentration during the dry season is 516±554 CFU/m3 at the mud concentrator, 364±202 CFU/m3 at the filling unit, 340±181 CFU/m3 at the anaerobic digester, and 231±201 CFU/m3 at the aerobic-anaerobic biofilter. As for the rainy season, the average fungi concentration is 58±39 CFU/m3 at the filling unit, 55±33 CFU/m3 at the mud concentrator, 36±32 CFU/m3 at the anaerobic digester, and 32±23 CFU/m3 at the aerobic-anaerobic biofilter. It can be seen that for the bacteria concentration, its highest value occurs at the filling unit during the dry season while its lowest value occurs at the anaerobic digester during the rainy season. For the fungi concentration, its highest value occurs at the mid concentrator during the dry season while its lowest value occurs at aerobic-anaerobic biofilter during the rainy season. The bacteria and fungi concentration values lie below the standard of quality. There are several correlations between environmental factors and the bacteria and fungi concentration values in some of the observed locations. There is also a difference between the bacteria and fungi concentration during the dry season and the rainy season.
"
Depok: Fakultas Teknik Universitas Indonesia, 2019
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Cindy Ruth Maharini
"Rumah Pemotongan Hewan (RPH) di Indonesia seringkali belum memenuhi standar operasional, higienis dan sanitasi yang berlaku. Dengan demikian, hal tersebut dapat menimbulkan risiko pencemaran udara mikrobiologis oleh bakteri dan jamur. Penelitian ini bertujuan untuk mengetahui kualitas udara mikrobiologis pada RPH, serta pengaruh parameter fisik lingkungan dan jumlah hewan ternak terhadap konsentrasi mikroba di udara dengan parameter bakteri, jamur, dan bakteri E. coli. Pengambilan sampel udara mikrobiologis dilakukan sebanyak 5 kali. Sampel diambil diambil menggunakan alat EMS Bioaerosol Sampler, dengan menggunakan media TSA untuk bakteri, media MEA untuk jamur, dan media EA untuk E. coli, serta dilakukan secara triplo. Kemudian, hubungan antara jumlah hewan ternak dalam kandang hewan dan konsentrasi mikroba di udara akan dianalisis menggunakan uji statistik parametris dengan uji korelasi. Hasil pengukuran sampel menunjukkan konsentrasi bakteri dan jamur yang sebagian besar belum memenuhi baku mutu indoor Keputusan Menteri Kesehatan Republik Indonesia No. 1405/Menkes/SK/XI/2002, sementara baku mutu outdoor Polish Standard PN-Z-04111-02:1989 telah terpenuhi pada dua lokasi outdoor. Konsentrasi mikroba indoor rata-rata 2.565 CFU/m3 dan seluruh lokasi tidak memenuhi baku mutu, dan konsentrasi mikroba outdoor rata-rata 2.983 CFU/m3 . Hasil korelasi statistik menunjukkan korelasi yang kuat antara peningkatan jumlah hewan ternak dengan konsentrasi mikroba di udara dengan nilai korelasi rata-rata diatas 0,5.

Abattoirs (RPH) in Indonesia often do not meet operational standards, hygienic and sanitary regulations. Thus, it can pose a risk of microbiological air contamination by bacteria and fungi. This study aims to determine the microbiological air quality at the abattoir, also the influences of the physical parameters of the environment and the number of cattle on the concentration of airborne microbes with the parameters of bacteria, fungi, and E. coli. Microbiological air sampling was performed 5 times. Samples were taken using EMS Bioaerosol Sampler, using medium TSA for bacteria, MEA medium for fungi, and EA medium for E. coli, the samples were taken in triplo. Then, the correlations between the number of cattles and microbial air concentration were analyzed with statistic parametric test using the correlation test. The samples measurement showed that most of the concentrations of bacteria and fungi haven?t meet the indoor microbial air quality standard (Kemenkes No. 1405/Menkes/SK/XI/2002) and outdoor microbial air quality standard (Polish Standard PN-Z-04111-02: 1989) that has been fulfilled by two outdoor locations, with the average concentration of indoor microbial air concentration at 2.565 CFU/m3, and the average of outdoor microbial air concentration at 2.983 CFU/m3. Statistical correlation analysis showed a strong correlation between the increase of the number of cattles along with microbial air concentration by the average correlation values of above 0.5."
Depok: Fakultas Teknik Universitas Indonesia, 2016
S64366
UI - Skripsi Membership  Universitas Indonesia Library
cover
Ani Marlina S.
"ABSTRAK
Penggunaan lahan sebagai Instalasi Pengolahan Limbah Terpadu IPLT Kalimulya, Depok dapat berpotensi mencemari air tanah yang digunakan penduduk sekitarnya. Salah satu parameter yang digunakan sebagai indikasi pencemar yaitu Fecal coliform. Keberadaan Fecal coliform berpotensi dapat menimbulkan penyakit seperti diare. Tujuan dari penelitian ini yaitu untuk mengetahui keberadaan dan jumlah Fecal coliform dalam air tanah warga sekitar IPLT, faktor penyebab, serta hubungan antara jarak sumur air tanah dari IPLT dengan jumlah Fecal coliform. Terdapat 30 sampel air tanah yang diuji dengan menggunakan metode Multiple Tube Fermentation MTF dan analisa korelasi dengan menggunakan persamaan Pearson Product Moment. Hasil pengujian yaitu sebanyak 90 dari total sampel masih berada di bawah baku mutu berdasarkan PP No. 82 Tahun 2001 dan 16.67 sesuai baku mutu berdasarkan PERMENKES RI No. 492/MENKES/PER/IV/2010. Berdasarkan hal tersebut dapat dikatakan bahwa air tanah masih tergolong baik untuk digunakan. Hasil korelasi memperlihatkan persebaran data sangat variatif sehingga tidak dapat menunjukkan bahwa kandungan Fecal coliform dalam air tanah warga berasal dari IPLT. Analisa hasil juga menunjukkan bahwa mayoritas faktor kontaminan berasal dari septictank setiap rumah serta dipengaruhi juga oleh keberadaan sungai Ciliwung.

ABSTRACT
Land used for the Depok rsquo s Septage Treatment Plant can potentially contaminate groundwater which is used by citizens in area around IPLT. One of the parameters that are used as an indicator of contamination is fecal coliform. The existence of fecal coliform can potentially cause illness such as diarrhea. The purpose of this study was to determine the existence and amount of fecal coliform on the groundwater in area around the IPLT, the causes of fecal coliform rsquo s contamination, and the relationship between the distance of groundwater rsquo s well from IPLT and the number of fecal coliform. There are 30 samples were tested using Multiple Tube Fermentation MTF and analysis the relation using Pearson Product Moment equation. The test result showed that 90 of the samples met the quality standart based on PP no. 82 of 2001 and 16.67 of the samples met the quality standard based on the Permenkes RI No. 492 of 2010. It is indicated that the groundwater was still relatively good. The results showed that correlation of data distribution is varied so it can rsquo t showed that the presence of fecal coliform concentration in the groundwater came from the IPLT. Analysis of the results also showed that the majority of contaminant rsquo s factors derived from the septictank each house and was also influenced by the Ciliwung river."
2017
S66810
UI - Skripsi Membership  Universitas Indonesia Library
cover
Grace Oktavina
"Kualitas udara luar ruangan, khususnya kualitas udara mikrobiologis, belum menjadi perhatian khusus di Indonesia. Kualitas udara mikrobiologis seharusnya mendapat perhatian khusus karena pencemaran oleh mikroorganisme ke udara dapat memicu persebaran infeksi dan penyakit-penyakit lain. Penelitian ini dilakukan terhadap kualitas udara di TPA Cipayung, Depok, Jawa Barat, dan udara di permukiman sekitar TPA untuk mengetahui konsentrasi mikroorganisme dan jangkauan persebarannya di udara. Tujuan penelitian ini adalah: (1) menganalisis besarnya konsentrasi jamur Aspergillus fumigatus di area TPA Cipayung Depok; (2) menganalisis tingkat penyebaran jamur A. fumigatus pada kawasan permukiman di sekitar TPA Cipayung Depok; (3) menganalisis faktor-faktor yang mempengaruhi persebaran jamur A. fumigatus di udara di sekitar TPA Cipayung Depok. Pengambilan sampel udara dilakukan di 5 titik di TPA dan 5 titik lainnya di permukiman pada jarak 50, 100, 250, 500, dan 1.000 meter. Sampel udara diambil menggunakan alat EMS Bioaerosol Single Stage Sampler dengan debit aliran udara sebesar 28,3 L/menit. Pengambilan sampel udara untuk parameter jamur dilakukan selama satu menit pada media Malt Extract Agar dan diinkubasi pada temperatur 29-30C selama ± 48-72 jam. Parameter utama yang diteliti merupakan jamur A. fumigatus. Koloni yang tumbuh dihitung sebagai Colony-forming Units (CFU/m3). Hasil penelitian menunjukkan hasil angka kuman (konsentrasi A. fumigatus), temperature, kelembaban udara, dan kecepatan angin di TPA Cipayung pada rentang 43+13,5-1151.6+484,2 CFU/m3, 27-42oC, 40-83,8%, dan 0,4-3 m/s. Hasil pengukuran konsentrasi jamur A. fumigatus diuji secara statistik menggunakan uji non-parametrik untuk menunjukkan korelasinya dengan jumlah truk yang beraktivitas dan hasil menunjukkan korelasi (A>¼ >0,05) pada konsentrasi jamur A. fumigatus dengan jumlah truk yang beroperasi. Berdasarkan pengukuran dan perhitungan, nilai kecepatan jatuh dari spora A. fumigatus sesuai dengan Hukum Stokes, yaitu sebesar 0,000576-2,556 x10-3 m/jam dan termasuk ke dalam jenis submicroscale transport. Besarnya konsentrasi jamur yang ditemukan dapat dipengaruhi oleh suhu, kelembaban udara, dan kecepatan angin. Sementara itu, jumlah truk yang lewat serta melakukan kegiatan unloading sampah dapat mempengaruhi penambahan jumlah konsentrasi jamur karena dapat dikategorikan menjadi sumber garis (launching).

Indonesia has yet to pay a serious attention to study about outdoor air quality, especially microbial air quality. It is a subject that must be seriously studied because microorganism-sponsored air pollution could cause the spread of infection and other diseases. This study aims to assess air quality at Cipayung Landfill in Depok, West Java, and the air in the vicinity of the facility so that the concentration and the dispersion in the air of microorganism could be detected. This study aims to: (1) analyze the concentration of Aspergillus fumigatus inside the Cipayung Landfill area; (2) analyze the movement rate of A. fumigatus in air inside the Cipayung Landfill area; (3) analyze the factors influencing the movement of A. fumigatus in air inside the Cipayung Landfill area. The air sampling for the study was conducted in five points at the Cipayung Landfill area and in five points at the neighborhood around the landfill. The author obtained the air sample through using the EMS Bioaerosol Single Stage Sampler with air flow rate at 28.3 liter/minute. The air sampling, used for fungi parameter, was conducted for one minute using the Malt Extract Agar medium, which was then incubated at temperatures between 29 and 30 degree Celcius for 48 to 72 hours. The primary parameter of the study is the A. fumigatus. The grown colony is counted as colony-forming units (CFU/m3). The results show that the concetration of A. fumigatus, temperature, humidity level and wind speed at Cipayung Landfill are, 43+13,5-1151.6+484,2 CFU/m3, 27-42oC, 40-83,8%, dan 0,4-3 m/s. The measurement results of A. fumigatus concentration is assessed by a non-parametric assessment to show its correlation with the number of trucks conducting activities at the facility. The results show the correlation (A>¼>0,05) between the two. Based on measurement and calculation, the downward velocity of the spores of A. fumigatus is inline with the Stokes Law at 0,000576-2,556 x10-3 m/hour and is part of submicroscale transport. The amount of fungi concentration found at the facility is influenced by temperature, humidity and wind speed. Meanwhile, the number of trucks passing at the facility and unloading waste there could influence the rise of concentration of fungi because it can be categorized as a linear source (launching)."
Depok: Fakultas Teknik Universitas Indonesia, 2018
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Amelia Yasmine Cahyaningrum
"Klinik merupakan fasilitas pelayanan kesehatan yang berhubungan dengan berbagai macam pasien dan penyakit sehingga kualitas udara mikrobiologis dalam ruangan perlu diperhatikan terkait resiko kesehatan. Oleh karenanya tujuan dari penelitian ini adalah untuk mengetahui sumber pencemar mikrobiologis pada Klinik, nilai konsentrasi bakteri dan jamur di udara, faktor lingkungan yang mempengaruhi konsentrasi bakteri dan jamur dan pengaruh jumlah pasien terhadap konsentrasi bakteri dan jamur di dalam ruangan. Identifikasi sumber pencemar dilakukan menggunakan ceklist dan skoring yang mengacu pada National Research Council (2005) dan Peraturan Menteri Kesehatan RI No 1204 Tahun 2004 tentang Persyaratan Kesehatan Lingkungan Rumah Sakit Lampiran 3 Formulir Penilaian Pemeriksaan Kesehatan Lingkungan (Inspeksi Sanitasi) Rumah Sakit. Selanjutnya sampel udara diambil menggunakan alat EMS E6 Bioaerosol Sampler Single-Stage dengan debit aliran udara sebesar 28,3 L/menit. Sampel udara diambil selama 2 menit pada media Malt Extract Agar dan diinkubasi pada suhu 28°C selama ±48 jam untuk jamur, serta 1,5 menit pada media Triptone Soya Agar dan diinkubasi pada suhu 37°C selama ±24 jam untuk bakteri. Sumber pencemar potensial pada Klinik Satelit UI antara lain keberadaan manusia, adanya pertumbuhan mikroba pada dinding maupun langit-langit ruangan, adanya water reservoirs seperti wastafel dan keberadaan soft furniture yang menghasilkan beberapa lokasi yang diduga memiliki konsentrasi bioaerosol tinggi, yaitu Poli Umum, Poli Gigi, IGD, Laboratorium, Ruang Administrasi dan Ruang Tunggu. Hasil penelitian menunjukkan bahwa konsentrasi bakteri tertinggi terdapat pada Ruang Tunggu (743 ± 10) CFU/m3 dan terendah pada Ruang Administrasi (348 ± 24) CFU/m3. Konsentrasi jamur tertinggi terdapat pada Ruang Poli Gigi (689 ± 40) CFU/m3 dan terendah pada Ruang Administrasi (457± 14) CFU/m3. Berdasarkan hasil uji statistik menggunakan metode Spearman Rank dengan p value (<0,01) suhu udara, kelembapan dan jumlah pasien merupakan parameter yang paling dominan mempengaruhi pertumbuhan dan perkembangan bioaerosol. Dengan korelasi tertinggi antara konsentrasi bakteri dan jamur dengan suhu adalah (r = 0,689 ) dan (r = -0,695), korelasi tertinggi dengan kelembapan adalah (r = 0,574) dan (r = 0,761) dan jumlah pasien memiliki korelasi konsentrasi tertinggi dengan bakteri dan jamur sebesar (r = 0,829) dan (r = 0,855). Dimana berdasarkan Permenkes No 1204 Tahun 2004, standar untuk suhu udara di Fasilitas Kesehatan adalah (19-26)°C dan kelembapan yang baik berkisar antara (45-60)%. Untuk mencegah perkembangan bioaerosol pada lingkungan Klinik Satelit UI diperlukan pengaturan suhu dan kelembapan yang baik, serta perawatan berkala untuk peralatan Klinik dan berbagai furniture serta pengecatan dinding minimal 1 kali dalam 1 tahun.

Clinics are health care facilities that are related to various types of patients and diseases so that indoor microbiological air quality needs to be considered related to health risks. Therefore the purpose of this study is to determine the microbiological pollutant sources in the clinic, the concentration of bacteria and fungi in the air, environmental factors that affect the concentration of bioaerosols and the effect of the number of patients on the concentration of bacteria and fungi in the room. Identification of pollutant sources was carried out using checklists and scoring referring to the National Research Council (2005) and Regulation of the Minister of Health of the Republic of Indonesia No. 1204 of 2004 concerning Hospital Environmental Health Requirements Appendix 3 Assessment Form for Hospital Environmental Health Inspections (Sanitation Inspection). Furthermore, the air sample was taken using the EMS E6 Bioaerosol Sampler Single-Stage with an air flowrate of 28,3 L/min. Air samples were taken for 2 minutes on Malt Extract Agar and incubated at temperature 28°C for ±48 hours for fungi, and 1,5 minutes on Triptone Soya Agar media and incubated at temperature 37°C for ±24 hours for bacteria. Potential pollutant sources at the Klinik Satelit UI include human presence, microbial growth in the walls and ceilings of the room, the presence of water reservoirs such as sinks and the presence of soft furniture which concludes that several locations are suspected of having high bioserosol concentrations, is General Poly, Poly Dental, IGD, Laboratory, Administration Room and Waiting Room. The results showed that the highest bacterial concentration was found in the Waiting Room (743±10) CFU/m3 and the lowest was in the Administration Room (348±24) CFU/m3. The highest fungal concentration was found in the Dental Poly Room of (689±40) CFU/m3 and the lowest was in the Administration Room of (457±14) CFU/m3. Based on statistical tests using the Spearman Rank method with p value (0,01), air temperature, humidity and number of patients are the most dominant parameters affecting the growth and development of bioaerosol. With the highest correlation between bacterial and fungal concentrations with temperature is (r=0,689) and (r=-0,695), with humidity is (r=0,574) and (r=0,761) with number of patients is (r=0,829) and (r=0,855). Where based on Ministry of Health Regulation No. 1204 of 2004 the standard for air temperature in Health Facilities is (19-26)°C and good humidity ranges between (45-60)%. To prevent the development of bioaerosol in the Klinik Satelit UI good temperature and humidity settings are needed, as well as periodic maintenance for Clinic equipment and furniture and painting wall at least 1 time a year."
Depok: Fakultas Teknik Universitas Indonesia, 2019
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Rohadatul Aisy Afla
"Kualitas udara pada ruang rawat inap merupakan poin penting yang perlu diperhatikan untuk menghindari risiko dan gangguan kesehatan yang dapat tersebar melalui udara. Indikator bioaerosol dalam ruangan yang dipakai adalah bakteri dan jamur. Alat yang digunakan untuk pengambilan sampel bakteri dan jamur pada Gedung A RSCM adalah EMS dan media kultur TSA serta MEA. Sampel bakteri diinkubasi pada suhu ±37oC selama ±24 jam, sedangkan jamur diinkubasi pada suhu ±27oC selama ±48 jam. Tujuan dari penelitian ini adalah untuk mengetahui perbedaan konsentrasi bakteri dan jamur pada ruang perawatan kelas 1, VIP, dan VVIP dan menganalisis faktor lingkungan yang dapat mempengaruhi keberadaan bioaerosol dalam ruangan. Dari penelitian yang telah dilakukan, hasil uji perbedaan konsentrasi bakteri pada ruang rawat inap yang diperoleh adalah 0,02 dengan tingkat signifikansi (α) 0,05 dengan menggunakan uji Kruskal-Wallis, sedangkan untuk jamur sebesar 0,002. Sehingga ada perbedaan konsentrasi bakteri dan jamur pada ruang perawatan kelas 1, VIP, dan VVIP. Suhu dan kelembaban diketahui sebagian besar tidak memiliki hubungan dengan kualitas bioaerosol dalam ruang rawat inap. Hasil uji korelasi Spearman untuk suhu dan bakteri adalah 0,085; 0,567; 0,000, sedangkan untuk suhu dan jamur adalah 0,058; 0,168; 0,05. Uji korelasi Spearman untuk kelembaban dan bakteri 0,095; 0,688; 0,320, sedangkan untuk kelembaban dan jamur adalah 0,399; 0,008; 0,920. Dari data tersebut dapat dijelaskan bahwa pada beberapa ruangan rawat inap tidak ada hubungan antara faktor lingkungan dengan konsentrasi bakteri dan jamur.

Air quality in the patient room is an notable point that need to be considered to avoid risk and some health problems that can be spread through the air. Bioaerosol indicator for indoor air pollutants are bacteria and fungi. Air samples were taken by EMS with TSA and MEA culture media. This research was taken in Gedung A RSCM. Bacteria sampel would be incubated at 37oC for 24 hours, while fungi would be incubated at ±27oC for ±48 hours. This research wanted to know the difference between bacteria and fungi concentration at kelas 1, VIP, and VVIP inpatient rooms. The results showed that there is a difference of bacteria and jamur concentration between the class of inpatient rooms, because the level significant of Kruskal-Wallis (α = 0,05) for bacteria concentration is 0,02 and 0,002 for fungi concentration. Temperature and humidity mainly did not have any specific relation with bioaerosol quality in inpatient rooms. The results for Spearman’s corelation for humidity and bacteria are 0,085; 0,567; 0,000. Meanwhile, for temperature and bacteria area 0,095; 0,688; 0,320 and for humidity and fungi are 0,399; 0,008; 0,920. From those data known that some of the inpatient rooms were not had relation between environment factors with bacteria and fungi concentration."
Depok: Fakultas Teknik Universitas Indonesia, 2019
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Hutagalung, Winny Laura Christina
"Lumpur pada sludge drying bed Instalasi Pengolahan Lumpur Tinja (IPLT) Kalimulya Depok dimanfaatkan masyarakat sekitar sebagai penyubur tanah. Padahal, lumpur tersebut belum memenuhi kriteria untuk dijadikan penyubur tanah. Oleh karena itu, diperlukan satu pengolahan untuk memperbaiki kualitas lumpur tersebut. Pengolahan yang digunakan dalam penelitian ini adalah pengomposan yang mencampur lumpur dari sludge drying bed dan sampah organik pasar dengan menggunakan metode open windrow. Pengomposan merupakan proses eksotermik yang akan menghasilkan panas dan pengukuran suhu dilakukan selama proses pengomposan berlangsung. Dalam percobaan pengomposan ini, dua perlakuan pengadukan yang berbeda diberikan pada dua buah komposter. Kompos diaduk dengan frekuensi dua dan empat hari. Kualitas yang diteliti dalam penelitian ini adalah Fecal coliform dan Salmonella sp.
Hasil penelitian menunjukkan bahwa pengadukan empat hari mampu mencapai suhu hingga 66,40C, sedangkan kompos dengan pengadukan dua hari hanya mencapai suhu 65,20C. Hasil pengukuran jumlah Fecal coliform adalah 23 MPN/gr pada hari ke-15, sedangkan jumlah Salmonella sp adalah <2 MPN/4gr pada hari ke-30. Ketika suhu mencapai suhu termofilik (35-650C), maka jumlahkedua bakteri tersebut akan berkurang. Dengan demikian, pengomposan mampu menurunkan jumlah bakteri Fecal coliform dan Salmonella sp sehingga dapat memenuhi SNI 19-7030-2004 tentang Spesifikasi Kompos dari Sampah Organik Domestik. Namun, terjadi pertumbuhan kembali bakteri dan secara signifikan ditunjukkan dengan jumlah Fecal coliform yang meningkat pada hari ke-30 dan 40, yaitu mencapai 50 MPN/gr dan 300 MPN/gr. Titik maturasi kompos tidak hanya dilihat dari kualitas mikrobiologisnya, tetapi juga dari kestabilan suhu, reduksi volume, bau, warna, dan tekstur kompos. Secara umum, variasi frekuensi pengadukan dua dan empat hari sekali tidak menghasilkan perbedaan yang mencolok. Untuk percobaan pengomposan yang lebih efektif, maka pengadukan yang lebih disarankan adalah frekuensi pengadukan 4 hari.

Sludge that is coming from sludge drying bed in Kalimulya Waste Water Treatment Plant City of Depok was used as soil fertilizer by community nearby. In fact, these sludge do not meet with standard as soil fertilizer and requires other treatment to improve its quality. This research was conducted to treat this sludge by open windrow composting method. This sludge was mixed with organic waste from traditional market. Composting is an exothermic process that is produced heat. The temperature increased due to the heat was measured during process takes place. There are two different turning frequencies performed which are every two and four days. The compost quality parameters that is examined are Fecal coliform and Salmonella sp. SNI No. 19-7030-2004 - Specification of The Domestic Organic Waste Composting was used as a base for compost quality standard.
The result shows that four days turning frequency could reach highest temperature at approximately 66.40C. Meanwhile, two days frequency only could reach highest temperature approximately 65.20C. The average number of Fecal coliform at day 15 is approximately 23 MPN/gr and Salmonella sp at day 30 is not more than 2 MPN/4gr. Composting could reduce the number of both bacteria. However, bacterial regrowth occurred and significantly indicated by number of Fecal coliform that increased at day 30 and 40, those are 30 MPN/gand 300 MPN/g. The matured compost is not only seen from its microbial quality, but also temperature, volume reduction, odor, color, and texture stability. In general, the compost quality did not show significant difference between two and four days turning frequency. But, four days turning frequency is preffered for effectivity and keeping temperature high during composting.
"
Depok: Fakultas Teknik Universitas Indonesia, 2012
S43231
UI - Skripsi Open  Universitas Indonesia Library
cover
Fatma Nur Rosana
"Rumah sakit merupakan salah satu fasilitas kesehatan yang berhubungan dengan obat-obatan, antibiotik, dan bahan kimia. Hal tersebut menyebabkan air limbah yang dihasilkan cenderung bersifat infeksius sehingga diperlukan pengolahan terlebih dahulu agar memenuhi baku mutu yang ditetapkan dalam Pergub DKI Jakarta No. 69 Tahun 2013. Namun, IPAL juga dapat menjadi sumber pencemaran lain, berupa pencemaran udara mikrobiologis. Penelitian ini bertujuan untuk mengetahui konsentrasi bakteri dan fungi akibat keberadaan IPAL serta menganalisis jeni bakteri yang ada melalui pewarnaan Gram. Pengambilan sampel udara menggunakan alat EMS E6 sesuai pedoman AIHA. Hasil pengukuran menunjukan konsentrasi rata-rata bioaerosol pada IPAL rumah sakit sekitar 1.100-3.200 CFU/m3 untuk bakteri dan 1.500-2.700 CFU/m3 untuk fungi dengan konsentrasi bakteri dan fungi tertinggi pada bak ekualisasi, sekitar 3.200 CFU/m3, dan pada bak aerasi, sekitar 2.680 CFU/m3. Hasil tersebut telah melebihi nilai background, yaitu 80 CFU/m3 untuk bakteri dan 440 CFU/m3 untuk fungi. Tingginya konsentrasi bioaerosol dapat dipengaruhi oleh faktor teknis IPAL maupun lingkungan disekitarnya. Selain itu, hasil pewarnaan Gram menunjukan 94% merupakan bakteri Gram negatif yang cenderung bersifat patogen. Oleh karenanya, diperlukan upaya pencegahan paparan bioaerosol bagi kesehatan maupun lingkungan, seperti mengisolasi IPAL dengan membangun dinding beton dan ventilasi, pemilihan teknologi unit pengolahan yang digunakan, dan penggunaan APD untuk pekerja di IPAL.

Hospital is one of health facilities associated to drugs, antibiotics, and chemicals. Those cause wastewater tends to be infectious so that must be processed to comply with the quality standard based on DKI Jakarta Governor Regulation No. 65 of 2013. However, WWTP can also be other sources of pollution, such as microbiology air pollution. The objective of this research are to determine bacteria and fungi concentration due to the presence of the WWTP and to analyze the types of bacteria that exist through Gram staining. Microbial air samples were taken by using EMS E6 according to AIHA guideline. The measurements showed that the average of bioaerosol concentration at hospital WWTP about 1.100-3.200 CFU/m3 for bacteria and 1.500-2.700 CFU/m3 for fungi, with the highest concentration of bacteria and fungi is found in equalization tank, about 3.200 CFU/m3, and aeration tank, about 2.680 CFU/m3. These results exceed the background value, about 80 CFU/m3 for bacteria and 440 CFU/m3 for fungi. The high concentration of bioaerosol can be affected by technical factors of WWTP and the surrounding area. Identification of Gram staining showed that 94% of bacteria found are Gram-negative that tend to be pathogenic. Therefore, it is necessary to prevent bioaerosol exposure to health and the surrounding environment, such as to build concrete walls and ventilation which surround WWTP, to specify technology of treatment plant used, and the use of PPE for workers at WWTP."
Depok: Fakultas Teknik Universitas Indonesia, 2016
S63646
UI - Skripsi Membership  Universitas Indonesia Library
cover
Almira Nur Hanifah
"Skripsi ini membahas tentang gambaran karakteristik wanita yang melakukan kunjungan deteksi dini kanker leher rahim pada Kecamatan Cilodong, khususnya Kelurahan Cilodong, Jatimulya, Kalibaru, Kalimulya, dan Sukamaju, Kota Depok Tahun 2018. Penelitian ini adalah penelitian mixed method, yaitu secara kuantitatif dan kualitatif dengan desain studi deskriptif. Variabel yang akan diteliti pada penelitian kuantitatif adalah usia, pendidikan, pekerjaan, riwayat kanker keluarga, usia pertama kali berhubungan seksual, frekuensi menikah, usia pertama kali hamil, paritas, penggunaan kontrasepsi, riwayat merokok, dan riwayat merokok pasangan pada kunjungan deteksi dini kanker leher rahim. Hasil penelitian kuantitatif menunjukkan bahwa adanya perbedaan karakteristik pada variabel usia, pendidikan, pekerjaan, riwayat kanker keluarga, dan frekuensi menikah pada kelima kelurahan di Kecamatan Cilodong. Sedangkan hasil penelitian kualitatif adalah program safari IVA gratis setiap tahun, promosi dilakukan pada media sosial dan oleh kader, kader memberikan penyuluhan di posyandu, pengetahuan informan yang baik, faktor pendorong adalah gratis, khwatir akan kesehatan, malu, dan merasa sehat, serta ajakan dari Kader berpengaruh terhadap pelaksanaan deteksi dini.

This thesis disscus about characteristic distribution of women who came to cervical early detection in Cilodong Distrcit, escecially Cilodong, Jatimulya, Kalibaru, Kalimulya, and Sukamaju Sub-district by the year 2018. This thesis is using mixed method, quantitative and qualitative with descriptive study design. Variables that are analyzed are age, education, occupation, family history of cancer, first age of sexual encounter, marriage frequancy, age of first pregnancy, parity, contraception use, smoking history, and partner’s smoking history in early detection visit. Quantitative analysis shows there are differences of characteristic distribution of age, education, occupation, family history of cancer, and marriage frequency in all five sub-district. Qualitative analysis results are there are free-charge IVA every year, promotion are done in social media and by Kader, Kader gives promotions in Posyandu, informants’ good knowledge, free-charge IVA, worried of their own health, and feel healthy are reinforce factor, also Kader influences to persuade women are important in cervical cancer ealy detection visit."
Depok: Fakultas Kesehatan Masyarakat Universitas Indonesia, 2021
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Dita Dwi Astuti
"Kantin banyak digunakan oleh mahasiswa sebagai tempat untuk berbagai kegiatan sehingga kualitas udara mikrobiologis pada lingkungan kantin menjadi diperhatikan terkait dengan risiko kesehatan. Oleh karena itu, perlu dilakukan penelitian untuk mengetahui sumber pencemar mikrobiologis pada kantin, seberapa besar konsentrasi bakteri dan jamur di udara, faktor-faktor apa saja yang mempengaruhi pertumbuhan dan perkembangan bakteri dan jamur di udara, serta menganalisis penyebaran bakteri dan jamur yang dilakukan pada kantin FT dan FEB UI. Identifikasi sumber pencemar dilakukan menggunakan checklist yang mengacu pada Keputusan Menteri Kesehatan Republik Indonesia Nomor 1098/MENKES/SK/VII/2003 tentang Persyaratan Hygiene Sanitasi Rumah Makan dan Restoran Lampiran II Formulir Inspeksi Pemeriksaan Kelaikan Hygiene Sanitasi Rumah Makan dan Restoran. Kemudian sampel udara diambil menggunakan EMS E6 Bioaerosol Sampler Single-Stage dengan debit aliran udara sebesar 28,3 L/menit. Sampel diambil selama dua menit pada media Tryptic Soy Agar dan diiinkubasi pada temperatur 35 C selama 24jam untuk bakteri serta pada media Malt Extract Agar dan diinkubasi pada temperatur 25 C selama 48jam untuk jamur. Pengambilan sampel dilakukan selama lima hari. Lokasi-lokasi yang diduga sebagai sumber pencemar berdasarkan hasil identifikasi yang telah dilakukan adalah Dapur Kantin Dosen FT; Depan Ruang Cuci Piring Kantin Mahasiswa FT; Depan Meja Piring Kotor Lantai 1 Kantin Mahasiswa FT; Kedai Pedagang Kantin Mahasiswa FT; Depan Meja Piring Kotor Lantai 2 Kantin Mahasiswa FT; Ruang Cuci Peralatan Kantin Mahasiswa FEB; serta Depan Kedai Pedagang dan Ruang Makan Kantin Mahasiswa FEB. Hasil penelitian menunjukkan bahwa Konsentrasi bakteri tertinggi ditemukan pada FT2 sebesar 561 100 CFU/m3 dan terendah pada FT5 156 69 CFU/m3. Konsentrasi jamur tertinggi pada FT5 461 224 CFU/m3 dan terendah pada FT1 144 81 CFU/m3. Berdasarkan uji statistik menggunakan metode korelasi Pearson didapatkan hasil dimana temperatur dan kelembaban udara memiliki korelasi yang lemah terhadap konsentrasi bakteri r=0,218;r=0,211 namun memiliki korelasi yang kuat terhadap konsentrasi jamur r=0,701;r=0,659 pada kedelapan lokasi sampling. Sedangkan intensitas cahaya memiliki korelasi yang sangat lemah terhadap konsentrasi bakteri r=0,115 dan korelasi lemah terhadap konsentrasi jamur r=0,226 pada kedelapan lokasi sampling. Kecepatan angin dan kegiatan manusia diduga menjadi beberapa faktor yang mempengaruhi penyebaran mikroorganisme. Sedangkan ukuran partikel menjadi salah satu faktor kecepatan pengendapan dimana jamur memiliki ukuran yang lebih besar dibandingkan bakteri sehingga kecepatan jatuh jamur lebih cepat dibandingkan bakteri. Kecepatan pengendapan partikel bakteri dan jamur berada pada kisaran 0,0005-0,28 cm/detik.

Canteen is widely used by students as a place for various activities so that microbiological air quality in the canteen environment to be considered related to health risks. Therefore, research needs to be completed to find out the source of microbiological pollutant in the canteen, knowing the concentration of bacteria and fungi in the air, analyze what factors influence the growth and expansion of bacteria and fungi in the air, and analyze the pathway of bacteria and fungi at Canteen of Faculty of Engineering and Faculty of Economic and Business UI. Identification of souce of microbiological pollutant using a checklist referring to the Minister of Health Decree No. 1098 MENKES SK VII 2003 about Hygiene Requirements for Sanitation of Restaurants. Air Sampling was conducteb by using EMS E6 Bioaerosol Sampler Single Stage and worked at a flowrate of 28.3 l min. Sampels were collected for two min on Tryptic Soy Agar and were incubated at 35 C for 24 h for bacteria and on Malt Extract Agar and were incubate at 25 C for 48 h for the fungal. Sampling was conducted for five days. Locations suspected to be souce of pollutants based on the results of identification that have been done are kitchen of FT rsquo s lecturer canteen In front of the dish washer room of FT 39 s student canteen In front of unwashed dish table 1st floor of FT rsquo s student canteen Between Food Stall of FT rsquo s student canteen In front of 2nd Floor FT rsquo s student canteen In washing room of FEB rsquo s student canteen and in front of food stall and dining room of FEB rsquo s student canteen. The results showed that the highest bacterial concentrations were found in FT2 561 100 CFU m3 and the lowest at FT5 156 69 CFU m3. The highest fungal concentration at FT5 461 224 CFU m3 and the lowest on FT1 144 81 CFU m3. Based on statistical test using Pearson correlation method got result where temperature and humidity have weak correlation to airborne bacteria concentration r 0,218 r 0,211 but have strong correlation to airborne fungal concentration r 0,701 r 0,659 at eight sampling location. While the light intensity has a very weak correlation to airborne bacterial concentration r 0,115 and weak correlation to airborne fungal concentrations r 0,226 in the eight sampling location. Wind speed and human activity are suspected to be several factors affecting the spread of microorganisms. While the particle size becomes one of the factors of settling speed where fungal have a larger size than bacteria so the speed falls faster than bacteria. The rate of deposition of bacterial and fungal particles in the range 0,0005 0,28 cm sec."
Depok: Fakultas Teknik Universitas Indonesia, 2018
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
<<   1 2 3 4 5 6 7 8 9 10   >>