Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 178890 dokumen yang sesuai dengan query
cover
Wairara, Tricia Lusia Novalia
"Pelayanan air perpipaan di Indonesia yang masih kurang mendorong masyarakat untuk menggunakan sumber air nonperpipaan seperti air tanah dan air isi ulang. Namun berdasarkan beberapa penelitian, air nonperpipaan diketahui memiliki risiko akibat kontaminasi bakteri dan patogen. Studi ini dilakukan sebagai upaya peningkatan kualitas air minum dengan mengetahui persebaran kontaminasi E. coli, faktor yang mempengaruhinya, serta membandingkan risiko kesehatan air minum nonperpipaan di Kota Bekasi dan Metro. Penelitian dilakukan dengan metode Most Probable Number (MPN) untuk mengetahui konsentrasi bakteri dan metode Quantitative Microbial Risk Assessment (QMRA) dengan indikator bakteri E. coli dan patogen indeks Salmonella. Pengujian kualitas air minum menunjukkan bahwa terjadi kontaminasi E. coli sekitar 26,7% dari total 202 sampel di Kota Bekasi dengan rata-rata 18,7 MPN/100 mL. Sedangkan di Kota Metro 30,0% dari 190 sampel terkontaminasi E. coli dengan rata-rata 77,3 MPN/100 mL. Berdasarkan uji korelasi Spearman¸ faktor seperti sumber air, pewadahan, dan pengolahan air tidak menunjukkan adanya korelasi terhadap konsentrasi E. coli, kecuali untuk faktor pewadahan di Kota Metro yang berhubungan signifikan dengan E. coli ≥100 MPN/100 mL. Kemudian hasil penelitian mengenai rasio patogen indeks Salmonella dengan sampel air tanah di kota Bekasi (n=7) diperoleh nilai rasio sebesar 0,03. Hasil perhitungan analisis QMRA dengan simulasi Monte-Carlo di Kota Bekasi menunjukkan bahwa air tanah memiliki nilai median beban penyakit sebesar 0,01 ± 0,03 DALY/orang/tahun dan air isi ulang dengan nilai sebesar 0,003 ± 0,02 DALY/orang/tahun. Sedangkan, untuk Kota Metro diperoleh sebesar 0,04 ± 0,04 DALY/orang/tahun untuk air tanah dan air isi ulang sebesar 0,03 ± 0,04 DALY/orang/tahun. Seluruh nilai yang diperoleh melebihi batas nilai maksimum menurut WHO yaitu sebesar 10-4 DALY/orang/tahun. Oleh karena itu, intervensi yang tepat perlu dilakukan oleh pemerintah untuk mengedukasi masyarakat tentang konsumsi air minum yang aman dan layak

Piped water services in Indonesia are still relatively low. This condition encourages people to use non-piped water sources such as groundwater and refilled water. However, based on several studies, non-piped water is known to have risks due to bacterial and pathogen contamination. This study was conducted as an effort to improve drinking water quality by knowing the distribution of E. coli contamination, the factors that influence it, and comparing the health risks of non-piped drinking water in Bekasi City and Metro. The research was conducted using the Most Probable Number (MPN) method to determine the concentration of bacteria and the Quantitative Microbial Risk Assessment (QMRA) method with E. coli as indicators and Salmonella as reference pathogen. The drinking water quality testing showed that there was around 26.73% E. coli contamination from a total of 202 drinking water samples in Bekasi City with an average of 18.74 MPN/100 mL. Whereas in Metro City 30% of 190 samples were contaminated with E. coli with an average of 77.31 MPN/100 mL. Based on the Spearman correlation test¸ risk factors such as water sources, containers, and water treatment did not show a correlation with E. coli concentrations, except for the container factor in Metro City which is significantly related to E. coli ≥100 MPN/100 mL. Then to find out the reference pathogen ratio, a Salmonella concentration test was carried out for groundwater in the city of Bekasi (n=7) and a ratio value of 0.03 was obtained. The results of QMRA analysis calculations using Monte-Carlo simulations in Bekasi City show that groundwater has a median disease burden value of 0.01 ± 0.03 DALY/person/year and refill water with a value of 0.003 ± 0.02 DALY/person/year year. Whereas for Metro City, the median disease burden of groundwater was 0.04 ± 0.04 DALY/person/year and for refill water it was 0.03 ± 0.04 DALY/person/year. All values ​​obtained exceeded the maximum value limit according to WHO, namely 10-4 DALY/person/year, therefore proper intervention from the government is needed to educate the public about consumption of safe drinking water."
Depok: Fakultas Teknik Universitas Indonesia, 2023
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Vina Fadhya Rahman
"Air tanah merupakan sumber air minum utama bagi 73,7% masyarakat Indonesia. Pencemaran tinja pada air tanah berpotensi menimbulkan dampak buruk bagi kesehatan manusia, di mana ditandai dengan ditemukannya bakteri E. coli dan Enterococci pada air tanah. Penelitian ini dilakukan untuk menganalisis konsentrasi E. coli dan Enterococci pada sampel air tanah di Kota Depok, serta menganalisis risiko kesehatan yang ditimbulkan akibat paparan mikroorganisme tersebut. Kandungan E. coli dan Enterococci pada air tanah diidentifikasi menggunakan kultur bakteri, sedangkan penilaian risiko menggunakan metode Quantitative Microbial Risk Assessment (QMRA). Hasil penelitian menunjukkan rata-rata konsentrasi E. coli dan Enterococci berkisar antara 0–1716,67 CFU/100 mL dan 0–266,67 CFU/100 mL, di mana hanya 1 dari 6 sampel yang memenuhi baku mutu kesehatan. Hasil uji korelasi menunjukkan terdapat hubungan yang berbanding terbalik antara konsentrasi bakteri pada air dengan jarak sumur terhadap pencemar (rEc= -0,142; rEn= -0,120) maupun dengan kedalaman sumur (rEc= -0,561; rEn= -0,896). Penilaian risiko menggunakan metode QMRA dilakukan menggunakan rasio E. coli O157:H7 serta Enterococcus faecalis dan Enterococcus faecium sebagai strain dan spesies yang paling umum dijumpai yang dapat menyebabkan penyakit diare pada manusia. Beban penyakit (DB) diare akibat E. coli dan Enterococci adalah sebesar 0,00137 DALY/orang/tahun, dan 0,000986–0,00109 DALY/orang/tahun, di mana nilai ini belum sesuai dengan health outcome target dari WHO untuk negara berkembang (0,0001 DALY/orang/tahun). Penelitian ini menunjukkan bahwa konsumsi air yang terkontaminasi bakteri E. coli dan Enterococci akibat tangki septik dan lindi dapat berbahaya bagi kesehatan. Sehingga perlu dilakukan intervensi, seperti perbaikan dan perawatan tangki septik sesuai SNI 2398:2017, peningkatan efektivitas praktik pengolahan air di rumah tangga, serta peningkatan manajemen lindi oleh TPA Cipayung Depok.

Groundwater is the main source of drinking water for 73.7% of Indonesian population. Fecal contamination in groundwater has the potential to cause adverse impacts on human health, which is characterized by the presence of E. coli and Enterococci in groundwater. This study was conducted to analyze the concentration of E. coli and Enterococci in groundwater samples in Depok City, and to analyze the health risks posed by exposure to these microorganisms. The concentration of E. coli and Enterococci in groundwater was identified using bacterial culture. While risk assessment was conducted using the Quantitative Microbial Risk Assessment (QMRA) method. The results showed that the average concentration of E. coli and Enterococci in groundwater samples ranged from 0-1716.67 CFU/100 mL and 0-266.67 CFU/100 mL, respectively, where only 1 of 6 samples met the health quality standards. The correlation test showed that there is an inversely proportional relationship between the concentration of bacteria in the water with the distance of the well to the pollutant (rEc = -0.142; rEn = -0.142) as well as with the depth of the well (rEc = -0.868; rEn = -0.904). Risk assessment using the QMRA method was conducted using the ratio of E. coli O157:H7 and Enterococcus faecalis and Enterococcus faecium as the most preavelent strains and species that can cause diarrheal disease in humans. The disease burden (DB) of diarrhea due to the exposure of E. coli and Enterococci were 0,00137 DALY/person/year and 0,000986–0,00109 DALY/person/year, respectively, which exceeded the WHO health outcome target for developing countries (0,0001 DALY/person/year). This study showed that consumption of water contaminated with E. coli and Enterococci from septic tanks and leacheate could be harmful to human health. Thus, interventions need to be taken, such as repairing and maintaining septic tanks as specified in SNI 2398:2017, increasing the effectivity of water treatment practices in households, and improving leachate management by TPA Cipayung Depok.
"
Depok: Fakultas Teknik Universitas Indonesia, 2023
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Virly Ferliani Aswirta
"Kota Metro merupakan salah satu kota dengan tingkat pelayanan air perpipaan yang rendah (5,05%), sehingga sebagian besar masyrakatnya menggunakan air tanah dengan sistem self-supply. Akan tetapi, keamanan sistem sumber self supply saat ini menjadi isu di masyarakat. Metode continuous monitoring dari April – Oktober 2021 melalui telepon setiap bulan dilakukan untuk membantu penilaian tingkat layanan air minum. Tujuan dari penelitian ini adalah menganalisis variabilitas sumber air bersih dan air minum, menganalisis variabilitas tingkat pelayanan air minum yang dipersepsikan aman, menganalisis variabilitas biaya operasional dan pengelolaan layanan sumber air minum di rumah tangga, dan menganalisis intervensi pengolahan air minum di rumah tangga untuk meningkatkan kualitas air minum. Analisis dilakukan dengan analisis statistik deskriptif dan software SPSS 24 untuk uji Regresi Logistik Biner. Hasil menunjukkan 97% sumber air masyarakat Kota Metro adalah sumber air self-supply, yang didominasi oleh sumur gali tak terlindungi milik pribadi (45% sumber air bersih dan 30% sumber air minum). Berdasarkan persepsi rumah tangga (keamanan, rasa, penampilan, bau, keandalan, dan ketersediaan air minum), air isi ulang dan air kemasan memiliki tingkat keamanan paling konsisten selama 6 bulan survei (100%). Sistem non-self-supply diketahui lebih aman dari sistem self-supply dengan persentase 98% dan 95%. Variabel kejadian banjir diketahui signifikan terhadap penilaian tingkat pelayanan sumber air minum yang dipersepsikan aman dengan peluang 0,059 kali dalam mempengaruhinya. Rata-rata biaya yang dibutuhkan untuk maintenance mesin pompa adalah Rp 683.750,00 dan untuk maintenance lainnya (pipa, kran air, dll) sekitar Rp 85.833,00 per rumah tangga. Sedangkan biaya yang dihabiskan oleh 1 rumah tangga dalam 1 minggu untuk air isi ulang adalah sekitar Rp 19.751,00, sedangkan untuk air kemasan sekitar Rp 40.986,00. Variabel yang mempengaruhi biaya air minum adalah pengolahan air dengan perebusan yang berpeluang 0,029 kali. Berdasarkan persepsi rumah tangga, masalah sumber air minum yang paling banyak terjadi pada sumber air baku adalah penampilan (29,4%) dan bau (28,3%), serta kadar E.coli (72%) pada air minum. Dengan demikian, dibutuhkan intervensi strategi pengolahan air minum untuk mengatasi permasalahan yang ada dan meningkatkan kualitas air minum. Adapun intervensi pengolahan air minum yang direkomendasikan untuk menyelesaikan masalah tersebut adalah Slow Sand Filter (SSF) dengan media tambahan berupa Granular Activated Carbon (GAC) serta unit disinfeksi sinar UV.

Metro City is one of the cities with a low level of piped water service (5,05%), so that most of the people use groundwater with a self-supply system. However, the safety of the self-supply source system is currently an issue in society. A continuous monitoring method from April – October 2021 by telephone every month was carried out to help assess the level of drinking water services. The purpose of this study are to analyze the variability of clean water and drinking water sources, to analyze the variability of the level of drinking water services that are perceived as safe, to analyze the variability of operational and maintenances costs of drinking water facility in households, and to analyze the intervention of drinking water treatment in households to improve the quality of drinking water. The analysis was carried out using descriptive statistical analysis and SPSS 24 software for the Binary Logistics Regression test. The results show that 97% of Metro City's water sources are self-supply water sources, which are dominated by private unprotected dug wells (45% for clean water sources and 30% for drinking water sources). Based on household perceptions (safety, taste, appearance, smell, reliability, and availability of drinking water), refill and bottled water had the most consistent level of safety during the 6 months of the survey (100%). Non-self-supply systems are known to be safer than self-supply systems with a percentage of 98% and 95%, respectively. The flood incident variable is known to be significant to the assessment of the service level of drinking water sources that are perceived as safe with a 0,059 times chance of influencing it. The average cost required for pump engine maintenance is Rp 683.750,00 and for other maintenance (pipes, water faucets, etc.) it is around Rp 85.833,00 per household. Meanwhile, the cost spent by 1 household in 1 week for refill water is around Rp 19.751,00, while for bottled water it is around Rp 40.986,00. The variable that affects the cost of drinking water is water treatment by boiling which has a chance of 0.029 times. Based on household perceptions, the most common drinking water source problems that occur in raw water sources are appearance (29,4%) and smell (28,3%) and E.coli (72%) in drinking water. Thus, intervention strategies for drinking water treatment are needed to overcome existing problems and improve drinking water quality. The recommended drinking water treatment intervention to solve this problem is the Slow Sand Filter (SSF) with additional media in the form of Granular Activated Carbon (GAC) and UV disinfection unit."
Depok: Fakultas Teknik Universitas Indonesia, 2021
T-pdf
UI - Tesis Membership  Universitas Indonesia Library
cover
Michelle Natasya Tanuwijaya
"Terlepas dari usaha untuk meningkatkan akses berkelanjutan ke air minum yang aman, ratusan juta orang masih bergantung pada sumber air unimproved. Untuk meningkatkan kualitas air minum, berbagai pengolahan air rumah tangga dan metode penyimpanan aman telah dikembangkan dan dikenalkan sebagai intervensi alternatif. Namun, informasi mengenai kualitas air minum dan prevalensi praktik pengolahan air minum rumah tangga, terutama dari perspektif dan tingkat kepuasan masyarakat masih sangat minim. Penelitian ini dilakukan untuk mengkaji kualitas air minum di Kota Metro, menganalisis persepsi dan tingkat kepuasan masyarakat terhadap air minumnya, serta menganalisis hubungan antar variabel. Survei lapangan dan observasi (n=281), serta pengambilan sampel air minum (n=79) dilakukan pada rumah tangga di Kota Metro. Pengujian kualitas sampel air minum dilakukan untuk parameter kekeruhan, Total Dissolved Solid (TDS), dan E. Coli. Pada uji kekeruhan dengan turbidimeter, ditemukan 4% sampel (n=79) memiliki kekeruhan yang melebihi baku mutu dengan rata-rata 1,3 NTU sedangkan uji TDS dengan multi-parameter probe menemukan bahwa tidak terdapat sampel yang melebihi baku mutu dengan rata-rata 82,46 mg/l. Tingkat risiko E. Coli pada air minum E. Coli beragam dengan rata-rata melebihi baku mutu Permenkes No. 492 Tahun 2010 yaitu sebesar 43,14 MPN/100 ml. Berdasarkan uji analisis korelasi Spearman Rank’s, ditemukan bahwa seluruh variabel memiliki korelasi yang signifikan antara persepsi serta tingkat kepuasan dengan kualitas air minum. Nilai korelasi Spearman dari tiap hubungan berada dalam rentang 0,232 hingga 0,276 sehingga seluruh variabel berkorelasi lemah dengan arah hubungan positif dan menunjukkan bahwa terdapat hubungan berkekuatan lemah antara persepsi dan tingkat kepuasan masyarakat dengan kualitas air minum dimana semakin baik kualitas air minum, persepsi dan tingkat kepuasan masyarakat juga semakin baik. Adapun rekomendasi yang perlu dilakukan dari studi ini ialah melakukan pemantauan dan pemeliharaan rutin pada sumber air minum mulai dari air tanah hingga depot air minum isi ulang dimana ditemukan kontaminasi E. Coli dengan risiko tinggi dan mengkomunikasikannya, mengadakan kampanye yang merekomendasi pengolahan air minum rumah tangga dan perawatan wadah penyimpanan air minum sesuai rekomendasi STBM pilar ke-3. 

Despite efforts to improve sustainable access to safe drinking water, hundreds of millions of people still depend on unimproved water sources. To improve drinking water quality, various household water treatment and safe storage methods have been developed and introduced as alternative interventions. However, information on drinking water quality and the prevalence of household drinking water treatment practices, especially from the perspective and level of community satisfaction, is still very minimal. This study was conducted to examine the quality of drinking water in Metro City, analyze the perception and level of community satisfaction with drinking water, and analyze the relationship between variables. Field surveys and observations (n=281), as well as drinking water sampling (n=79) were conducted on households in Metro City. Testing the quality of drinking water samples was carried out for the parameters of turbidity, TDS, and E. Coli. In the turbidity test with a turbidimeter, it was found that 4% of the samples (n=79) had turbidity that exceeded the quality standard with an average of 1,3 NTU, while the TDS test with a multi-parameter probe found that there were no samples that exceeded the quality standard with an average of 82,46 mg/l. The level of risk of E. Coli in drinking water of E. Coli varies with the average exceeding the quality standard of Permenkes No. 492 of 2010 which is 43,14 MPN/100 ml. Based on the Spearman Rank's correlation analysis test, it was found that all variables had a significant correlation between perceptions and levels of satisfaction with drinking water quality. The Spearman correlation value of each relationship is in the range of 0.232 to 0.276 so that all variables are weakly correlated with the direction of the positive relationship and indicate that there is a weak relationship between perceptions and levels of community satisfaction with drinking water quality where the better the quality of drinking water, perceptions and levels of community satisfaction also getting better The recommendations that need to be carried out from this study are carry out routine monitoring and maintenance on drinking water sources ranging from ground water to refill drinking water depots where high-risk E. Coli contamination is found and communicate it, conduct campaigns recommending household drinking water treatment and maintenance of drinking water storage containers according to the recommendations of the STBM-3rd pillar."
Depok: Fakultas Teknik Universitas Indonesia, 2022
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Endang Krisnawaty
"Penelitian ini bertujuan untuk melakukan analisis risiko pajanan timbal dalam air minum terhadap kejadian hipertensi pada penduduk yang bermukim di sekitar TPA Cipayung Kota Depok, Tahun 2019. Penelitian ini menggunakan metode PHA (Public Health Assessment) yaitu terdapat dua metode penelitian: ARKL (Analisis Risiko Kesehatan Lingkungan) dan EKL (Epidemiologi Kesehatan Lingkungan) dengan desain studi cross sectional. Hasil penelitian didapatkan tingkat risiko terhadap efek non karsinogenik pada pajanan timbal dalam air sumur yang dikonsumsi oleh penduduk di sekitar TPA Cipayung masih berada dibawah batas aman yaitu RQ real-time ≤1 (RQ real-time maksimal pada 0.669). Sedangkan pada perhitungan RQ lifespan 40 tahun didapatkan nilai RQ>1 yaitu RQ=1.071. Artinya responden yang mengkonsumsi air sumur terpajan timbal akan berisiko tidak aman terhadap gangguan kesehatan non karsinogenik pada 40 tahun yang akan datang. Perhitungan tingkat risiko terhadap efek karsinogenik pada pajanan timbal dalam air sumur yang dikonsumsi oleh penduduk di sekitar TPA Cipayung, pada jangka waktu 100 tahun yang akan datang berada pada batas aman (ECR 100 tahun = 1.37x10-6). Analisis bivariat yang dilakukan antara tingkat risiko pajanan timbal dalam air sumur dengan kejadian hipertensi tidak didapatkan hubungan yang signifikan dengan nilai p=0.322. Hasil analisis multivariat didapatkan peluang pada responden yang mengkonsumsi air sumur terpajan timbal sebesar 0.193 kali menderita hipertensi dibandingkan dengan responden yang tidak mengkonsumsi air sumur terpajan timbal setelah dikontrol oleh variabel konsumsi lemak jenuh, umur, kebiasaan merokok, aktivitas fisik kurang dan konsumsi garam tinggi.

This study aims to analyze the risk of lead exposure in drinking water to the incidence of hypertension in residents living around the TPA Cipayung in Depok City, 2019. This study uses the PHA (Public Health Assessment) method, there are two research methods: ARKL (Health Risk Analysis Environment) and EKL (Epidemiology of Environmental Health) with a cross sectional study design. The results showed that the level of risk for non-carcinogenic effects on lead exposure in well water consumed by residents around the TPA Cipayung was still below the safe limit of real-time RQ ≤1 (maximum real-time RQ at 0.669). The calculation of 40 years lifespan RQ is >1 (RQ = 1.071). This means that respondents who consume lead-exposed well water will be at risk of being unsafe for non-carcinogenic health problems in the next 40 years. Calculation of risk level for carcinogenic effects on lead exposure in well water consumed by residents living around the TPA Cipayung, in the period of 100 years to come is at the safe limit (ECR 100 years = 1.37x10-6). Bivariate analysis conducted between the level of risk of lead exposure in well water and the incidence of hypertension did not show a significant relationship with the value of p = 0.322. The results of multivariate analysis showed that respondents who consumed lead water exposed to 0.193 times had hypertension compared to respondents who did not consume lead-exposed well water after being controlled by variables of saturated fat consumption, age, smoking habits, lack of physical activity and high salt consumption"
Depok: Fakultas Kesehatan Masyarakat Universitas Indonesia, 2019
T52784
UI - Tesis Membership  Universitas Indonesia Library
cover
Firda Alfianti
"Latar Belakang : Air merupakan salah satu sumber daya yang menjadi kebutuhan dasar manusia untuk bertahan hidup. Air berhubungan erat dengan kesehatan manusia, sehingga kualitas air perlu mendapatkan perhatian khusus. Salah satu parameter yang mejadi indikator kualitas air minum adalah parameter mikrobiologi yaitu bakteri Escherichia coli dan Coliform. Kedua bakteri tersebut dapat menyebabkan masalah kesehatan seperti diare, kolera dan disentri. Universitas Indonesia merupakan salah satu Universitas terbaik di Indonesia telah berupaya menyediakan air minum melalui pemurni air untuk warga Universitas Indonesia. Tujuan : Menganalisis perbandingan kualitas mikrobiologi pada air sebelum filtrasi dan sesudah filtrasi di Universitas Indonesia. Metode : Penelitian ini merupakan penelitian analitik dengan pendekatan kuantitatif dan desain studi eksperimental yang dilakukan pada air sebelum dan sesudah filtrasi di 8 Fakultas Universitas Indonesia. Hasil : Hasil uji beda dua mean menunjukan bahwa bakteri Coliform (p = 0,028) terdapat perbedaan dan bakteri Escherichia coli (p = 1,000) tidak terdapat perbedaan kualitas pada air sebelum dan sesudah filtrasi. Kesimpulan : Terdapat perbedaan kandungan Coliform pada air sebelum dan sesudah filtrasi. Tidak terdapat perbedaan kandungan Escherichia coli pada air sebelum dan sesudah filtrasi.

Background: Water is one of the resources that is a basic human need for survival. Water is closely related to human health, so water quality needs special attention. One of the parameters that serve as an indicator of drinking water quality is the microbiological parameter, the bacteria Escherichia coli and Coliform. Both bacteria can cause health problems such as Diarrhoea, Cholera and Dysentery. Universitas Indonesia, one of the best universities in Indonesia, has endeavoured to provide drinking water through a water purifier for the citizens of Universitas Indonesia. Objective: Analyse the comparison of microbiological quality in pre-filtration and post-filtration water at Universitas Indonesia. Methods: This research is an analytical study with a quantitative approach and experimental study design conducted on water before and after filtration in 8 faculties of the University of Indonesia. Results: The results of the two-mean t-test showed that Coliform bacteria (p = 0.028) had a difference and Escherichia coli bacteria (p = 1.000) had no difference in quality before and after filtration. Conclusion: There is a difference in the coliform content of the water before and after filtration. There is no difference in Escherichia coli content in water before and after filtration.
"
Depok: Fakultas Kesehatan Masyarakat Universitas Indonesia, 2023
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Benita Dian Purnamasari
"Kondisi saat ini, cakupan layanan air PDAM Kota Bekasi masih sangat rendah hanya 27 persen dari total rumah tangga. Berdasarkan kondisi tersebut, pemerintah Kota Bekasi saat ini mengembangkan proyek Sistem Penyediaan Air Minum. Tujuan dari pengembangan Sistem Penyediaan Air Minum di Kota Bekasi untuk mendukung aktivitas berkaitan dengan edukasi, ekonomi lokal, pemerintah dan kegiatan lain yang mengarah dalam kebutuhan pelayanan air minum. Pembangunan Sistem Penyediaan Air Minum membutuhkan biaya investasi yang tinggi sehingga diperlukan analisis berbasis risiko untuk mengurangi kegagalan proyek, terutama dari segi aspek finansial.
Penelitian ini dilakukan dengan menggunakan metode Project Risk Management untuk menghitung dampak risiko terhadap investasi. Output penelitian berupa model risiko finansial yang kemudian dianalisa untuk disusun rekomendasi Risk Response Planning berupa keputusan alternatif untuk menghindari, memitigasi atau pun menerima risiko yang akan terjadi.

The existing condition of water service coverage of the district drinking water companies (PDAMs) Bekasi Municipal is very low with only 27 percent of the total household. According to this condition, Bekasi Municipal Government is currently developing a Drinking Water Supply project. The purpose of Drinking Water Supply System Development in Bekasi Municipal is to support activities of education, local economic, government and other activities which lead to enhance need of water services. The construction of water supply system requires a high investment costs which then resulted in the need of risk-based analysis to reduce of failure in financial aspects of the project.
The study was conducted by using Project Risk Management method to calculate the impact of risks in project investment. The output of the research is a financial risk model which is then analyzed to develop a risk responses planning which provides an alternative decision whether to avoid, mitigate, or accept the risks that might occur.
"
Depok: Fakultas Teknik Universitas Indonesia, 2014
S57227
UI - Skripsi Membership  Universitas Indonesia Library
cover
Wulan Maulidiah
"Pertumbuhan penduduk yang pesat diiringi dengan pembangunan infrastruktur pendukung pariwisata yang tidak terkontrol di daerah Bali Selatan berakibat pada persediaan air bersih yang kian menipis. Melihat kondisi tersebut, Pemerintah Provinsi Bali saat ini mengembangkan proyek pembangunan Sistem Penyediaan Air Minum (SPAM) dengan cakupan wilayah Denpasar, Badung, Gianyar, Tabanan, dan Klungkung. Proyek pembangunan SPAM ini membutuhkan biaya investasi yang sangat tinggi sehingga perlu adanya analisis berbasis risiko untuk mengurangi kemungkinan terjadinya kegagalan proyek baik dalam aspek operasional maupun pendanaan. Penelitian dilakukan dengan menggunakan metode Project Risk Management dengan pendekatan Value at Risk (VaR) untuk menghitung dampak risiko terhadap investasi. Output penelitian ini berupa model risiko finansial yang kemudian dianalisis untuk menyusun rekomendasi rencana penanganan risiko yaitu berupa keputusan untuk mencegah, mitigasi, atau menerima risiko yang mungkin akan terjadi. Hasil analisis menunjukkan bahwa dari tiga faktor risiko yang menjadi prioritas, risiko fluktuasi nilai tukar Rupiah terhadap U.S. Dollar memiliki pengaruh yang paling besar terhadap nilai arus kas bersih proyek.

Rapid population growth aligned with the uncontrolled development of tourism facilities leads South Bali to the depletion of clean water supply. According to this condition, Bali Provincial Government is currently developing a drinking water supply project that will cover area of Denpasar, Badung, Gianyar, Tabanan, and Klungkung. The construction of water supply system requires a high investment costs which then resulted in the need of risk-based analysis to reduce the likelihood of failure in both the operational and financial aspects of the project. The study was conducted by using Project Risk Management method with Value at Risk approach to calculate the impact of risks in project investment. The output of the research is a financial risk model which is then analyzed to develop a risk responses planning which provides an alternative decision whether to avoid, mitigate, or accept the risks that might occur. The analysis showed that of the three prority risk factors, exchange rate has the greatest influence on the net present value of the project.
"
Depok: Fakultas Teknik Universitas Indonesia, 2014
S57627
UI - Skripsi Membership  Universitas Indonesia Library
cover
Nur Hikmah Okvianti
"Pada pertambangan emas rakyat, akan terjadi pencemaran air raksa akibat proses pengolahan emas secara amalgamasi yang akan mempengaruhi kesehatan, disamping kerusakan alam lain seperti kerusakan bentang alam, erosi dan pendangkalan sungai. Penelitian ini bertujuan untuk mengetahui besaran risiko kesehatan akibat pajanan merkuri pada air yang dikonsumsi oleh penduduk di wilayah pertambangan emas skala kecil, Desa Lebaksitu, Kecamatan Lebakgedong , Kabupaten Lebak. Untuk menghitung besarnya risiko dilakukan sampling sebanyak 7 titik yang tersebar di 3 dusun dan dilakukan survey antropometri serta wawancara terhadap 72 penduduk yang tinggal di lokasi penelitian. Dari hasil pengukuran didapatkan nilai konsentrasi yang sama pada setiap sampel yaitu 0,0004 mg/L. Nilai RQ tertinggi jatuh pada responden dengan nilai 5.6522 dan nilai RQ terendah ada pada responden di Lebakpari dengan nilai RQ 0.2483.

In gold mining, mercury pollution will occur due to the processing of gold amalgamation that will affect the health, in addition to other environmental damage such as damage to the landscape, erosion and silting of the river. This study aims to determine the amount of the health risks from exposure to mercury in water consumed by residents in the area of ??small-scale gold mining, the village Lebaksitu, Lebakgedong subdistrict, Lebak. To calculate the amount of risk sampling as much as 7 point spread in 3 hamlets and performed anthropometric survey and interviews with 72 people living at the sites. From the measurement results obtained concentration values ??were the same in each sample was 0.0004 mg / L. The highest RQ score is 5.6522 and the lowest RQ values ??exist among respondents in Lebakpari with RQ value 0.2483."
Depok: Fakultas Kesehatan Masyarakat Universitas Indonesia, 2016
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Ahmad Mursidi
"Air merupakan sumber kehidupan bagi manusia. tidak ada satupun mahluk hidup termasuk manusia dapat bidup tanpa air, Air yang baik dan sehat adalah air yang teiah memenuhi persyaratan kesehatan baik fisikimia, biologi maupun radioaktivitas, sesuai dengan persyaratan kualitas air minum Kepmenkes nomor 907/MENKES/SK/VII/2002, Kualitas air minum parameter kimla kromium heksavalen dan arsen di kelurahan Karanganyar telah melebihi persyaratan kualits air minum Kepmenkes tersebut.
Tujuan penelitian adalah untuk mengetahui perkiraan risiko kesehatan akibat pajanan logam kromiun heksavalen dan arsen dalam air minum. Penelitian ini dilakukan terhadap penduduk Karanganyar yang menggunakan sarana air bersih sumur gali sebagai sumber air minum sebanyak 200 orang, dan pemeriksaan sampel air minum sebanyak 32 sampel.
Hasil penelitian didapatkan bahwa persentase responden yang mempunyai risiko penyakit non kanker akibat pajanan kromium heksavalen (RQ !) sedangkan persentase responden yang telah me!ampaui batas risiko penyakit non kanker akibat pajanan arsen (RQ> I) sebesar 59%.Besar risiko kanker akibat pajanan arsen rata­ rata pada responden sehesar 1,5 per !0.000 penduduk. Konsentrasi krornium heksava!en terbukti mempunyai huhungan dengan risiko kesehatan (p < 0,05) dengan nilai r = 0,927 dan hubungannya sangat kuat Konsentrasi arsen juga mempunyai hubungan dengan risiko kesehatan (p < 0,05) dengan nilai r = 0,936 dan hubungannya sangat kuat.
Kandungan kromium heksavalen dan arsen merupakan risk agent yang mempunyai hubungan sangat kuat dengan risiko kesehatan. maka perlu kirnnya dilakukan pemantauan dan pengendaiian terhadap risk agent tersebut dengan melakukan perbaikan dan penyedirum air minum yang haik dan sebat. Pemerintah daerah sudah seharusnya melalui dinas terkait untuk melakukan perencanaan program penyediaan dan perbalkan kualitas air, agar masyarakat terhindar dari risiko kesehatan akibat air minum yang tidak sehat.

Water is 1ife source for human, no creature including human could Jife without water. Good and healthy water is fulfilling health prerequirement whether physical, chemical. biology or radioactivity, according to water quality prerequirement of Kepmenkes number 9071MENKES/SKN1Ii2002. Chemical parameter of water quality of chromium heksavalen and arsenic at Kalanganyar chief of village has surpassing surpassing water quality prerequirement of Kepmenkes.
Research objective is to identity consequance of health risk measurement from chronium heksavalen metal exposure and arsenic in drinking water. This research performed to Kalanganyar residence that using hygiene well medium as drinking water source of 200 people, and drinking water sample examination of 32 samples.
Research result ob!ained that respondent percen!age, which has non-cancer disease risk because of chromium heksavalen exposure (RQ>l) as much as 16%, while Ii respondent percentage that has surpassing limitation of non cancer of arsenic exposure (RQ>I) as much as 59%. Cancer risk mte because of arsenic exposure averagely in respondent is 1.5 per 10,000 residences. Concentration of chromium heksava!en sho\ved has a relation with health risk (p < 0.05) with r-value = 0.927 and the relation is very strong. Concentration of arsenic also showed has a relation with health risk (p < 0.05) with r-value = 0.936 and the relation is very strong.
Substances of chromium heksavalen and arsenic is risk agent that has strong relation with health risk, therefore require to performed monitoring and controlling toward risk agent by performing maintenance and providing good and healthy drinking water. Regency government through related department of providing and maintaining water quality. so that public avoided from health risk of unhealthy drinking water.
"
Depok: Fakultas Kesehatan Masyarakat Universitas Indonesia, 2007
T31654
UI - Tesis Membership  Universitas Indonesia Library
<<   1 2 3 4 5 6 7 8 9 10   >>