Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 143752 dokumen yang sesuai dengan query
cover
Athaya Putri Indrani
"Latar Belakang: Material restorasi yang paling berkembang pesat sampai saat ini adalah resin komposit. Resin komposit yang beredar di pasaran dan menurun klaim pabrik memiliki sifat estetika yang baik, mudah dimanipulasi, serta dapat dipakai secara universal adalah Resin Komposit Supra-Nano Palfique Universal Flow. Suatu material restorasi harus mengalami polimerisasi yang adekuat agar menghasilkan sifat fisik, kimia, mekanik, dan biologis yang optimal. Sifat kekerasan mikro dan depth of cure material dapat menjadi indikator seberapa baik polimerisasi suatu material. Pada keadaan klinis, anatomi gigi dapat menghalangi sinar untuk berada tepat di atas permukaan restorasi sehingga jarak dan durasi penyinaran memengaruhi kekerasan mikro dan depth of cure resin komposit. Tujuan: Menganalisis pengaruh jarak dan durasi penyinaran terhadap kekerasan mikro dan depth of cure Resin Komposit Supra-Nano Palfique Universal Flow. Metode: Tiga puluh spesimen Resin Komposit Supra-Nano Palfique Universal Flow berbentuk silinder berdiameter 6 mm dan tinggi 2 mm dipersiapkan untuk penelitian ini. Spesimen terbagi menjadi 6 kelompok berdasarkan jarak penyinaran (0,3, dan 6 mm) dan durasi penyinaran (10 dan 15 detik) yang disinari light curing unit dengan iradiansi 1050 mW/cm2. Uji kekerasan dilakukan pada permukaan atas spesimen, dan diuji juga kekerasan pada permukaan bawah spesimen untuk menghitung depth of cure (DoC). DoC dihitung dengan menggunakan metode bottom/top hardness ratio (%). Data dianalisis menggunakan uji statistik One-way ANOVA dan Independent Sample T-test. Hasil: Kekerasan mikro dan DoC semakin tinggi pada jarak yang semakin dekat baik pada durasi 10 maupun 15 detik. Nilai kekerasan mikro dan DoC pada durasi penyinaran 15 detik lebih tinggi dibandingkan durasi penyinaran 10 detik pada jarak yang sama secara signifikan (p<0.05). DoC > 80% hanya didapatkan pada kelompok dengan jarak penyinaran 0 mm dengan durasi penyinaran 10 dan 15 detik yaitu 81,44 ± 0,02% dan 92,64 ± 0,01% secara berurutan, serta pada kelompok dengan jarak penyinaran 3 mm dan durasi penyinaran 15 detik, yaitu 88,78 ± 0,02%. Kesimpulan: Semakin dekat jarak penyinaran dan semakin lama durasi penyinaran, maka kekerasan mikro dan DoC akan semakin tinggi.

Background: The most rapidly developing restoration material to date is composite resin. The composite resin on the market and according to manufacturer claims has good aesthetic properties, is easy to manipulate and can be used universally is Palfique Universal Flow Supra-Nano Composite Resin. A material restoration must have an adequate polymerization to produce optimal physical, chemical, mechanical, and biological properties. The microhardness and depth of cure properties of a material can be an indicators of how well a material is polymerized. In clinical situations, anatomical teeth can prevent light from being directly above the surface of the restoration so that the distance and duration of light-curing affect the microhardness and depth of cure of the composite resin. Objective: To analyze the effect of light-curing distance and duration on the microhardness and depth of cure of Supra-Nano Palfique Universal Flow Composite Resin. Methods: Thirty specimens of Palfique Universal Flow Supra-Nano Composite Resin in a cylindrical shape with a diameter of 6 mm and a height of 2 mm were prepared for this study. Specimens were divided into 6 groups based on the light-curing distance (0,3, and 6 mm) and duration (10 and 15 seconds) which were exposed to a light curing unit with an irradiance of 1050 mW/cm2. The hardness test was on the top surface of the specimen, and hardness was also tested on the bottom surface of the specimen to calculate the depth of cure (DoC). DoC was calculated using the bottom/top hardness ratio (%) method. Data was analyzed statistically by One-way ANOVA and Independent Sample T-test. Results: Microhardness and DoC were higher at closer light-curing distances for both 10 and 15 seconds. Microhardness and DoC values at a light-curing duration of 15 seconds were significantly higher than at a duration of 10 seconds at the same distance (p<0.05). DoC > 80% was only obtained in the group with a light-curing distance of 0 mm with a duration of 10 and 15 seconds, that is 81.44 ± 0.02% and 92.64 ± 0.01% respectively, and 88.78 ± 0.02% in the group with a light-curing distance of 3 mm and a duration of 15 seconds. Conclusion: The closer the light-curing distance and the longer the light-curing duration, the higher the microhardness and DoC."
Jakarta: Fakultas Kedokteran Gigi Universitas Indonesia, 2023
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Ferditya Harley Perdana
"Latar belakang: Resin komposit nanofill dan bulkfill memiliki tampilan warna yang estetik. Warna resin komposit dapat berubah setelah dilakukan polimerisasi dengan light curing unit. Mode penyinaran pulsa yang memberikan suhu relatif rendah pada jaringan pulpa mulai dikembangkan sebagai alternatif penyinaran konvensional atau kontinu. Tujuan: Mengetahui pengaruh penyinaran mode kontinu dan pulsa terhadap perubahan warna resin komposit nanofill serta bulkfill. Metode: Penelitian eksperimental laboratorik menggunakan 24 spesimen resin komposit yang dibagi menjadi 4 kelompok perlakuan terdiri dari 2 kelompok penyinaran (pulsa dan kontinu) dan 2 kelompok resin komposit (nanofill dan bulkfill). Spesimen berbentuk silindris dengan diameter 6 mm dan tebal 2 mm yang direndam dalam 5 ml akuades serta disimpan dalam inkubator 37˚C selama 24 jam setelah dilakukan penyinaran untuk menyelesaikan polimerisasi. Pengujian warna dilakukan sebelum dan setelah polimerisasi dengan penyinaran pada spesimen menggunakan Colorimeter sebanyak 3 kali pada sisi yang sama namun posisi berbeda lalu diambil rata-rata untuk merepresentasikan seluruh permukaannya. Hasil: ΔL*, Δa*, Δb* dan ΔE hasil penyinaran kontinu baik pada resin komposit nanofill maupun bulkfill berturut-turut berkisar -1,03 – 1,30, 0,98 – 1,78, 1,24 – 2,66, dan 2,05 – 3,37. Sebagai pembanding, resin komposit nanofill dan bulkfill menghasilkan ΔL*, Δa*, Δb*, dan ΔE masing-masing berkisar dari -1,08 – 1,16, 0,97 – 1,69, 1,30 – 2,66, dan 2,04 – 3,34. Uji statistik menggunakan Independent T-Test menunjukkan ΔL*,Δa*, Δb* dan ΔE resin komposit nanofill hasil penyinaran mode kontinu dan pulsa berbeda tidak bermakna (p>0,05). Perbedaan tidak bermakna turut pula ditemui pada ΔL*,Δa*, Δb*, dan ΔE resin komposit bulkfill hasil kedua penyinaran (p>0,05). Kesimpulan: Mode penyinaran kontinu dan pulsa menghasilkan ΔL*, Δa*, Δb*, dan ΔE resin komposit nanofill maupun bulkfill yang tidak berbeda signifikan.

Background: Nanofill and bulkfill composite resins have an aesthetic color that could changed due to light curing polymerization. Pulse-lighting mode developed as an alternative to conventional or continous one in order to reduce temperature change on dental pulp cells. Aims: To evaluate the influence of continous-lightning and pulse-lightning mode on the discoloration of nanofill and bulkfill composite resins. Methods: Twenty four composite resin specimens devided into 2 groups of lighting mode (continous and pulse) and 2 materials (nanofill and bulkfill), 6 mm in diameter and 2 mm in thick prepared, then immersed in 8mL of aquadest and keep 37˚C incubator for 24 hours post irradiation in order to completion of polymerization. Changes in color parameter were measured using CIEL*a*b* system before and after composite resin polymerization for each specimen. Data were analyzed using Independent T-Test (p<0,05). Result: The ranges of ΔL*, Δa*, Δb* dan ΔE after continous-lighting on nanofill and bulkfill were -1,03 – 1,30, 0,98 – 1,78, 1,24 – 2,66 dan 2,05 – 3,37 respectively. In comparison, ΔL*, Δa*, Δb* dan ΔE after pulse-lighting on nanofill and bulkfill were -1,08 – 1,16, 0,97 – 1,69, 1,30 – 2,66 dan 2,04 – 3,34 respectively. ΔL*,Δa*, Δb* dan ΔE of nanofill composite resin on continous-lighting compared to pulse on nanofill composite resin exhibited no significant difference (p>0,05). The same result also found in bulkfill composite resin cured with continous-lighting compared to the pulse-lighting (p>0,05). Conclusion: Discolorization of nanofill and bulkfill composite resin induced by continous-lighting and pulse-lighting did not exhibit significanct difference.
"
Depok: Fakultas Kedokteran Gigi Universitas Indonesia, 2021
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Anindya Fiza
"Latar Belakang: Resin komposit merupakan bahan restorasi yang telah dikembangkan komposisinya sehingga memiliki sifat estetika, fisik, dan mekanik yang lebih baik dan diharapkan dapat mengatasi masalah yang disebabkan oleh material restorasi lainnya. Resin komposit PALFIQUE® Universal Flow dari Tokuyama Dental merupakan resin komposit yang telah dikembangkan partikel filler-nya dan diklaim memiliki kemampuan pemolesan yang tinggi serta estetika yang sempurna. Salah satu sifat permukaan restorasi resin komposit, surface gloss, memegang peranan penting terhadap estetika restorasi. Surface gloss dipengaruhi oleh berbagai faktor intrinsik dan ekstrinsik dan diantara faktor ekstrinsik yaitu sistem pemolesan. Tujuan: Menganalisis pengaruh sistem pemolesan terhadap surface gloss resin komposit supra-nano PALFIQUE® Universal Flow tipe Super Low dan Medium. Metode: Empat puluh delapan spesimen resin komposit supranano PALFIQUE® Universal Flow berbentuk silinder berdiameter 6 mm dan tinggi 2 mm dibuat untuk penelitian ini. Spesimen dibagi menjadi 6 kelompok berdasarkan tipe resin komposit (Super Low dan Medium) dan sistem pemolesan (Sof-LexTM Spiral, Sof- LexTM XT Polishing Discs, Tanpa Pemolesan). Penyinaran resin komposit dilakukan dengan light curing unit iradiansi 1050 mW/cm2 selama 12 detik. Setiap spesimen dilakukan pengujian surface gloss dengan glossmeter sebanyak tiga kali. Data dianalisis menggunakan uji statistik One-Way ANOVA dan Independent Sample T-Test. Hasil: Nilai surface gloss semua kelompok berada pada rentang 76–96 GU. Surface gloss tertinggi dimiliki oleh kelompok tanpa pemolesan. Sistem pemolesan Sof-LexTM XT Polishing Discs menghasilkan surface gloss lebih tinggi dibandingkan Sof-LexTM Spiral dengan perbedaan yang signifikan (p<0,05). Surface gloss resin komposit tipe Super Low lebih tinggi dibandingkan tipe Medium dengan perbedaan yang signifikan (p<0,01). Kesimpulan: Surface gloss turut dipengaruhi oleh tipe resin komposit dan sistem pemolesan.

Background: Composite resin is a restorative material with composition that has been developed so that it has better aesthetic, physical, and mechanical properties and is expected to overcome problems caused by other restorative materials. PALFIQUE® Universal Flow composite resin from Tokuyama Dental is a composite resin with developed filler particles and is claimed to have high polishing ability and perfect aesthetics. One of the surface properties of composite resin restorations, surface gloss, plays an important role in the aesthetics of the restoration. Surface gloss is influenced by various intrinsic and extrinsic factors and among the extrinsic factors is the polishing system. Objectives: The aim of this study was to analyze the influence of different polishing systems on surface gloss of Super Low and Medium PALFIQUE® Universal Flow composite resin. Materials and Methods: Forty-eight specimens of PALFIQUE® Universal Flow supra-nano composite resin in cylindrical shape (diameter of 6 mm and height 2 mm) were used in this study. The specimens were divided into six groups by type (Super Low and Medium) and by polishing systems (Sof-LexTM Spiral, Sof-LexTM XT Polishing Discs, mylar strip). Specimens were polymerized with light curing unit for 12 seconds with light irradiance of 1050 mW/cm2. Each specimen was tested for surface gloss with a glossmeter three times. Data then were analyzed with One-Way ANOVA and Independent Sample T-Test. Results: Surface gloss value of all groups were above the clinically acceptable threshold (76–96 GU). Highest surface gloss value was shown on the mylar strip group. Higher surface gloss values were produced by Sof-LexTM XT Polishing Discs compared to Sof-LexTM Spiral, statistically significant (p<0,05). Surface gloss values were significantly higher on type Super Low compared to Medium (p<0,01). Conclusion: In this study, surface gloss value was influenced both by the type of composite resin and differences in polishing systems."
Depok: Fakultas Kedokteran Gigi Universitas Indonesia, 2024
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Syarifah Auliyah Pratiwi
"Latar belakang: Pengaruh paparan klorheksidin 0,2% dan povidone iodine 1% atau aplikasi CP 10% pada bulkfill lebih sedikit dibandingkan nanofill atau jenis resin komposit lainya. Padahal nanofill dan bulkfill banyak digunakan sebagai restorasi estetik gigi anterior dan posterior. Oleh karena itu, perlu diketahui kekerasan resin komposit nanofill dan bulkfill setelah paparan dengan obat kumur klorheksidin 0,2% dan povidone iodine 1% yang sesuai aturan pakai diikuti dengan aplikasi CP 10%.
Tujuan: Menganalisa pengaruh pengaplikasian bleaching karbamid Peroksida 10% terhadap kekerasan resin komposit nanofill dan bulkfill setelah terpaparan obat kumur klorheksidin 0,2 % dan povidone iodine 1%.
Metode: Spesimen resin komposit nanofill dan bulkfill (n=24) dibagi menjadi 4 kelompok, lalu direndam dalam obat kumur Klorheksidin 0,2 % (n=6) dan Povidone iodine 1% (n=6) selama 2 menit/hari dalam 14 hari. Kemudian dilakukan pengaplikasian bleaching Karbamid Peroksida 10% selama 4 jam/hari dalam 14 hari. Pengujian kekerasan dilakukan pada awal, setelah paparan obat kumur, dan setelah aplikasi bleaching.
Hasil: Kekerasan resin komposit nanofill dan bulkfill di awal, setelah paparan obat kumur, dan setelah aplikasi karbamid peroksida 10% berbeda bermakna (p<0,05). Perbedaan bermakna juga ditemui antara kekerasan resin komposit nanofill dan bulkfill dengan paparan obat kumur yang sama (p<0,05). Pada resin komposit nanofill dan bulkfill yang terpapar obat kumur yang berbeda tidak terdapat perbedaan bermakna (p>0,05).
Kesimpulan: Resin komposit nanofill dan bulkfill mengalami penurunan kekerasan setelah diaplikasikan bleaching karbamid peroksida 10% yang terpapar obat kumur klorheksidin 0,2% dan povidone iodine 1%.

Background: The effect of 0.2% chlorhexidine and 1% povidone iodine exposure or 10% CP application on bulkfill is less than nanofill or other types of composite resins. Whereas nanofill and bulkfill are widely used as aesthetic restorations for anterior and posterior teeth. Therefore, it is necessary to know the hardness of nanofill and bulkfill composite resins after exposure to 0.2% chlorhexidine and 1% povidone iodine mouthwash according to the instructions for use followed by 10% CP application.
Objective: To analyze the effect of 10% carbamide peroxide bleaching application on the hardness of nanofill and bulkfill composite resins after 0.2% chlorhexidine and 1% povidone iodine exposure.
Methods: The nanofill and bulkfill composite resin specimens (n=24) were divided into 4 groups, then immersed in 0.2% Chlorhexidine (n=6) and 1% Povidone iodine (n=6) for 2 minutes/day for 14 days. Then apply 10% Carbamide Peroxide bleach for 4 hours/day for 14 days. Hardness testing was carried out at baseline, after exposure to mouthwash, and after bleaching application.
Results: The hardness of nanofill and bulkfill composite resins at baseline, after exposure to mouthwash, and after 10% carbamide peroxide application were significantly different (p<0.05). A significant difference was also found between the hardness of the nanofill and bulkfill composite resins with the same mouthwash exposure (p<0.05). There was no significant difference between nanofill and bulkfill composite resins exposed to different mouthwashes (p>0.05).
Conclusion: The nanofill and bulkfill composite resins decreased in hardness after the application of 10% carbamide peroxide bleaching which exposed to 0.2% chlorhexidine and 1% povidone iodine.
"
Depok: Fakultas Kedokteran Universitas Indonesia, 2022
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Yogi Pamungkas
"Latar Belakang : Resin komposit menjadi salah satu jenis material restorasi yang banyak digunakan karena memiliki keunggulan dalam sifat fisik, mekanik, dan estetika. Salah satu resin komposit yang beredar di Indonesia adalah Resin Komposit Palfique Supra-Nano Universal Flow yang dikembangkan partikel filler-nya dan diklaim memiliki sifat fisik yang baik antara lain water sorption dan solubility. Penggunaan resin komposit seiring waktu akan terpapar oleh lingkungan rongga mulut akibat adanya saliva yang pH-nya bisa berubah seiring konsumsi makanan dan minuman sehingga mempengaruhi water sorption dan solubility-nya. Hingga saat ini, belum terdapat penelitian mengenai pengaruh perendaman pada berbagai pH saliva buatan terhadap water sorption dan solubility Resin Komposit Palfique Supra-nano Universal Flow. Tujuan : Menganalisis pengaruh perendaman Resin Komposit Supra-Nano Palfique Universal Flow tipe Super Low dan Medium pada berbagai pH saliva buatan terhadap water sorption dan solubility. Metode : Empat puluh delapan spesimen Resin Komposit Supra-Nano Palfique Universal Flow tipe Super Low dan Medium dengan dimensi 15 x 1 mm dibagi menjadi delapan kelompok uji berdasarkan tipe dan perendaman, yaitu pada perendaman di dalam akuades, saliva buatan pH 3, 5,5, dan 7 masing-masing selama 7 hari. Perhitungan dari nilai water sorption dan solubility dilakukan sesuai ISO 4049 : 2019. Analisis data menggunakan uji One way ANOVA dan Kruskall Wallis. Hasil : Nilai water sorption dan solubility pada kedua tipe Resin Komposit Palfique Supra-nano Universal Flow semakin tinggi pada perendaman pH yang semakin rendah. Perendaman di dalam akuades dan saliva buatan pH 3 mengalami kenaikan secara signifikan (p<0,05), dan tidak signifikan pada perendaman di dalam saliva buatan pH 3 dengan pH 5,5 dan pH 7 (p<0,05). Nilai solubility pada perendaman di dalam saliva buatan pH 3 dengan pH 5,5 mengalami kenaikan secara signifikan (p<0,05), sedangkan pada saliva buatan pH 5,5 dengan 7 tidak signifikan (p>0,05). Tipe Super Low memiliki nilai water sorption dan solubility yang lebih tinggi dibandingkan tipe Medium pada semua perendaman namun tidak signifikan (p>0,05). Kesimpulan : Terjadi peningkatan nilai water sorption dan solubility Resin Komposit Palfique Supra-nano Universal Flow setelah perendaman di dalam saliva buatan pH 3 dibandingkan pH 5,5, 7, dan akuades.

Background : Composite resin is one type of restoration material that is widely used because it has advantages in physical, mechanical, and aesthetic properties. One of the composite resins distributed in Indonesia is Palfique Supra-nano Universal Flow Composite Resin which developed its filler particles and claimed to have good physical and mechanical properties, one of which is the physical properties of water sorption and solubility. The use of composite resins over time will be exposed to the oral environment due to the presence of saliva which pH of saliva can change with the consumption of food and drinks, that affecting the water sorption and solubility of the Composite Resin. Until now, there’s not yet research the effect of immersion at various pH artificial saliva on water sorption and solubility of Palfique Supra-nano Universal Flow Composite Resin. Objective : To analyze the effect of immersion type Super Low and Medium Palfique Supra-Nano Universal Flow Composite Resin at various pH artificial saliva on water sorption and solubilty. Methods : Forty-eight type Super Low and Medium Palfique Supra-Nano Universal Flow Composite Resin specimens with dimensions of 15 x 1 mm were divided into eight test groups based on type and immersion ; distilled water, artificial saliva pH 3, 5,5, and 7 for 7 days. Calculations of water sorption and solubility values will be made according to ISO 4049: 2019. Data analysis used One way ANOVA and Kruskall Wallis test. Results : The value of water sorption and solubility for both types (Super Low and Medium) is higher in immersion at lower pH. Immersion in distilled water and artificial saliva pH 3 in both types increased significantly (p<0.05), and in artificial saliva pH 3 with pH 5.5 and pH 7 was not significant (p<0.05). The solubility value in pH 3 immersion with pH 5.5 increased significantly (p<0.05), while at pH 5.5 and 7 it was not significant (p>0.05). The Super Low type has higher water sorption and solubility values than the Medium type in all immersions but not significant (p>0.05). Conclusion : There is an increase on water sorption and solubility of Palfique Supra-nano Universal Flow Composite Resin after immersion at artificial pH 3 compared to pH 5,5, 7, and distilled water."
Jakarta: Fakultas Kedokteran Gigi Universitas Indonesia, 2024
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Sabrina Nabila Putri
"Latar Belakang: Resin komposit monokromatik cerdas merupakan jenis terbaru dari resin komposit yang menawarkan stabilitas warna yang lebih baik dibandingkan resin komposit konvensional. Kopi, sebagai minuman yang sering dikonsumsi, diklaim dapat menyebabkan perubahan warna pada restorasi gigi. Pasta gigi pemutih dianggap efektif untuk mengembalikan warna restorasi yang mengalami perubahan warna. Tujuan: Tujuan dari penelitian ini adalah untuk mengevaluasi efek dari beberapa pasta gigi pemutih terhadap stabilitas warna resin komposit, serta efektivitas pemutihannya setelah terdiskolorasi oleh larutan kopi. Metode: Spesimen resin komposit supra-nano-filled(Omnichroma; Tokuyama, Tokyo, Jepang) (n=50) disiapkan dan dibagi menjadi lima subkelompok (n=10) : Kelompok 1, Kontrol ; Kelompok 2, Pasta gigi pemutih mengandung komposisi material abrasif (Colgate Total White- Colgate-Palmolive); Kelompok 3, Pasta gigi pemutih mengandung komposisi material kimia (Vussen 28-Osstem Oral Care Company, South Korea); Kelompok 4, Pasta gigi pemutih mengandung komposisi blue covarine (Meridol gentle white-CP-GABA, Germany); dan Kelompok 5, Pasta gigi pemutih mengandung komposisi activated charcoal (Colgate Optic White (Charcoal)-Colgate-Palmolive). Setiap subkelompok sampel disimpan dalam inkubator bersuhu 37°C selama 24 jam, direndam dalam larutan kopi selama 24 jam dan disikat selama 4 menit dengan pasta gigi masing-masing. Pengukuran warna dilakukan sebelum perendaman dalam kopi, setelah perendaman dalam kopi, dan setelah proses penyikatan, dengan membersihkan sampel secara menyeluruh dengan ultrasonic cleaner selama 1 menit sebelum setiap pengukuran. Hasil perubahan warna dianalisis menggunakan Parametric One Way ANOVA dan diikuti dengan uji Post-Hoc Bonferroni untuk menentukan perbedaan signifikan antar kelompok jika data menunjukkan perbedaan yang signifikan.Hasil: Berdasarkan hasil perbandingan antar kelompok penyikatan, terdapat perbedaan ΔE* yang signifikan secara statistik antara kelompok penyikatan dengan pasta gigi pemutih mengandung material kimia, penyikatan dengan pasta gigi pemutih mengandung material blue covarine, dan pasta gigi pemutih mengandung activated charcoal ketika dibandingkan dengan kelompok kontrol, sedangkan antara kelompok pasta gigi pemutih mengandung material abrasif tidak berbeda signifikan ketika dibandingkan dengan kelompok kontrol.Kesimpulan: Pasta gigi pemutih menunjukkan efek pemutihan pada resin komposit. Perubahan warna terbesar diperoleh setelah menggunakan pasta gigi mengandung material kimia (hydrogen peroxide), sementara perubahan warna terkecil diamati setelah menggunakan pasta gigi pemutih mengandung activated charcoal.

Background: Smart monochromatic composite resin is the latest type of composite resin offering better color stability compared to conventional composite resins. Coffee, as a frequently consumed beverage, is claimed to cause discoloration of dental restorations. Whitening toothpastes are considered effective in restoring the color of discolored restorations.Objective: This study aims to evaluate the effects of several whitening toothpastes on the color stability of composite resin and their whitening effectiveness after being discolored by coffee solution.Methods: Supra-nano-filled composite resin specimens (Omnichroma; Tokuyama, Tokyo, Japan) (n=50) were prepared and divided into five subgroups (n=10): Group 1, Control; Group 2, Whitening toothpaste with abrasive material composition (Colgate Total White-Colgate-Palmolive); Group 3, Whitening toothpaste with chemical material composition (Vussen 28-Osstem Oral Care Company, South Korea); Group 4, Whitening toothpaste with blue covarine composition (Meridol gentle white-CP-GABA, Germany); and Group 5, Whitening toothpaste with activated charcoal composition (Colgate Optic White (Charcoal)-Colgate-Palmolive). Each subgroup sample was stored in an incubator at 37°C for 24 hours, immersed in coffee solution for 24 hours, and brushed for 4 minutes with each respective toothpaste. Color measurements were taken before immersion in coffee, after immersion in coffee, and after the brushing process, with thorough cleaning of the samples using an ultrasonic cleaner for 1 minute before each measurement. The color change results were analyzed using Parametric One-Way ANOVA followed by Bonferroni Post-Hoc test to determine significant differences between groups if the data showed significant variation.Results: Based on the intergroup comparison of brushing, a statistically significant difference in ΔE* values was found between the groups brushed with whitening toothpaste containing chemical material, whitening toothpaste containing blue covarine, and whitening toothpaste containing activated charcoal when compared to the control group. No significant difference was observed between the abrasive whitening toothpaste group and the control group. Conclusion: It can be concluded that whitening toothpastes showed a whitening effect on composite resins. The greatest color change was observed after using whitening toothpaste containing chemical materials (hydrogen peroxide), while the smallest color change was observed after using whitening toothpaste containing activated charcoal."
Depok: Fakultas Kedokteran Gigi Universitas Indonesia, 2024
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Elgiva Kallita Tafiana
"Latar Belakang: Palfique Universal Flow® merupakan resin komposit flowable yang digunakan untuk merestorasi gigi anterior dan posterior. Untuk dapat beredar di pasaran, material restorasi harus memenuhi karakteristik standar, salah satunya adalah kekuatan fleksural. Material restorasi akan terpapar oleh lingkungan mulut yang kondisi pH-nya selalu berubah sehingga dapat berdampak pada kekuatan fleksuralnya. Tujuan: Menganalisis pengaruh perendaman resin komposit supra-nano Palfique Universal Flow® tipe medium pada berbagai pH saliva buatan terhadap kekuatan fleksural. Metode: Sejumlah dua puluh empat spesimen resin komposit supra-nano Palfique Universal Flow® tipe medium dengan dimensi 25 x 2,8 x 2 mm dikelompokkan menjadi empat, yaitu kelompok tanpa perlakuan, perendaman di saliva buatan pH 3, pH 5,5, dan pH 7. Setelah direndam selama 7 hari, kekuatan fleksural diukur menggunakan Universal Testing Machine. Data dianalisis menggunakan uji Kruskal Wallis, Mann-Whitney, dan Independent T-Test. Hasil: Nilai kekuatan fleksural pada kelompok tanpa perlakuan merupakan yang tertinggi dan semakin rendah pada perendaman di dalam saliva buatan pH 7; 5,5; dan 3 secara berturut-turut dengan perbedaan signifikan (p≤0,05). Nilai antar kelompok berbeda signifikan pada seluruh kelompok (p≤0,05), kecuali pada pH 3 dengan pH 5,5 dan pH 5,5 dengan pH 7 (p>0,05). Kesimpulan: Saliva buatan yang asam menyebabkan nilai kekuatan fleksural resin komposit supra-nano Palfique Universal Flow® tipe medium menjadi lebih rendah.

Background: Palfique Universal Flow® is a flowable composite resin that used for restoring both anterior and posterior teeth. To be marketed, restorative materials must meet standard characteristics, one of which is flexural strength. Restorative materials are exposed to the oral environment, where pH conditions continuously change, potentially affecting their flexural strength. Objective: To analyze the effect of immersion medium-type supra-nano composite resin Palfique Universal Flow®in artificial saliva at various pH levels on the flexural strength. Methods: Twenty-four specimens of medium-type supra-nano composite resin Palfique Universal Flow®, with dimensions of 25 x 2.8 x 2 mm, divided into four groups: untreated, immersion in artificial saliva with pH 3, pH 5.5, and pH 7. After a 7-days immersion, the flexural strength was measured using a Universal Testing Machine. The data were analyzed using Kruskal-Wallis, Mann-Whitney, and Independent T-Test. Results: The flexural strength values in the untreated group were the highest, decreasing within immersion in artificial saliva at pH 7, 5.5, and 3 with significant differences observed (p≤0.05). Significant differences were noted between groups in all cases (p≤0.05), except between pH 3 and pH 5.5, as well as between pH 5.5 and pH 7 (p>0.05). Conclusion: Artificial saliva with acidic pH levels leads to lower flexural strength values of the medium-type supra-nano composite resin Palfique Universal Flow®.
"
Depok: Fakultas Kedokteran Gigi Universitas Indonesia, 2024
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Alamsyah Putra
"Latar belakang : Resin komposit bulkfill merupakan resin terbaru yang dapat direstorasi dengan kedalaman 4-5 mm dalam sekali penyinaran. Polimerisasi dipengaruhi oleh durasi penyinaran dan besaran irradiansi lightcuring untuk mendapatkan kekerasan permukaan dan depth of cure yang optimal. Tujuan: Penelitian ini bertujuan untuk mengetahui perbedaan nilai kekerasan resin komposit dan depth of cure resin komposit Tetric® N- Ceram bulk-fill yang disinari lightcure dengan durasi 5 detik, 10 detik dan 15 detik. Metode Penelitian: Dalam penelitian ini digunakan 24 spesimen resin komposit Tetric® N-Ceram bulk-fill berbentuk silinder dengan ukuran diameter 6 mm dan tebal 4 mm. Selembar mylar strip diletakkan diatas permukaan resin komposit sebelum dilakukan proses curing. Polimerisasi dilakukan menggunakan Light Curing Unit (LED DBA iLed) selama 5 detik, 10 detik dan 15 detik dengan irradiansi 1100 mW/cm2. Setelah polimerisasi, spesimen direndam dalam akuades pada suhu 37oC selama 24 jam. Spesimen dibagi menjadi tiga kelompok (n=8) yaitu; kelompok resin komposit dengan penyinaran 5 detik, penyinaran 10 detik dan penyinaran 15 detik. Spesimen diuji menggunakan HMV-G Series Micro Vickers Hardness Tester (Shimadzu, Jepang) dengan beban 100 gram selama 10 detik untuk mendapatkan nilai kekerasan. Data dianalisis dengan uji statistik Kruskall Wallis dan Post-Hoc Mann Whitney. Hasil Penelitian: Hasil uji statistik menunjukkan kenaikan bermakna nilai kekerasan permukaan dan depth of cure pada resin komposit Tetric® N-Ceram bulk-fill. Nilai kekerasan dan depth of cure tertinggi terlihat pada resin komposit Tetric® N-Ceram bulk-fill pada kelompok penyinaran 15 detik, yaitu sebesar 41,61 ± 1,25 KHN dan 72,71 ± 1,88. Kesimpulan: Disimpulkan bahwa semakin bertambah durasi penyinaran lightcure yang disinari, semakin bertambah nilai kekerasan permukaan dan depth of cure resin komposit Tetric® N-Ceram bulk-fill.

Background : Bulkfill composite resin is the newest resin that can be restored to a depth of 4-5 mm in one step. Polymerization is determined by the irradiation time and the amount of light curing irradiance to obtain optimal microhardness and depth of cure. Objective: The aim of this study was to determine the difference in the value of the microhardness of the composite resin and the depth of cure of the Tetric® N-Ceram bulk- fill composite resin irradiated by lightcure with a duration of 5 seconds, 10 seconds and 15 seconds. Method: Twenty four specimens of Tetric® N-Ceram bulk-fill Composite Resin were used in this study. All materials were prepared into disk-shaped specimens of 6 mm in diameter and 4 mm in thickness. A piece of mylar strip was placed on the top of the specimens just before the polymerization.. Polymerization was carried out using a Light Curing Unit (LED DBA iLed) for 5 seconds, 10 seconds and 15 seconds with an irradiance of 1100 mW/cm2. After polymerization, specimens were immersed in 37 aquadest solution for 24 hours. Specimens were divided into three groups (n=8) that is; composite resin group with 5 seconds of irradiation, 10 seconds of irradiation and 15 seconds of irradiation. Specimens were tested with HMV-G Series Micro Vickers Hardness Tester (Shimadzu, Jepang) with 100 gram indentation in 10 seconds. Data were analyzed using Kruskall Wallis and Post-Hoc Mann Whitney to assess the significant differences among groups Result: The results of statistical tests showed a significant increase in the value of microharhardness and depth of cure on Tetric® N-Ceram bulk- fill composite resin. The highest microhardness and depth of cure values were seen in the Tetric® N-Ceram bulk-fill composite resin in the 15 second irradiation group, namely 41.61 ± 1.25 KHN and 72.71 ± 1.88. Conclusion: It was concluded that the longer the duration of irradiation of the irradiated lightcure, the higher the microhardness value and depth of cure of the Tetric® N-Ceram bulk-fill composite resin."
Jakarta: Fakultas Kedokteran Gigi Universitas Indonesia, 2022
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Vina Arlia Shafadilla
"Resin komposit termasuk dalam material restoratif direk yang proses pengerasannya melalui proses polimerisasi dibantu dengan bantuan cahaya. Penelitian ini bertujuan untuk mengetahui pengaruh jarak dan durasi penyinaran terhadap kekerasan permukaan resin komposit nanofilled. 60 spesimen resin komposit yang ditumpat dalam mold dibagi ke dalam 6 kelompok berdasarkan jarak dan durasi penyinaran yang berbeda yaitu 2 mm, 5 mm, dan 8 mm; serta 20 detik dan 40 detik. Rerata nilai tertinggi dimiliki oleh kelompok dengan jarak terkecil dan durasi penyinaran terlama sedangkan nilai rerata terendah terdapat pada kelompok dengan jarak terbesar dan durasi penyinaran tersingkat. Terdapat perbedaan bermakna antar tiap kelompok perlakuan dengan jarak yang berbeda, namun pada 2 kelompok yang memiliki jarak tip LED Light Curing Unit sebesar 8 mm, tidak ada perbedaan bermakna. Dapat disimpulkan, jarak tip LED Light Curing Unit dan durasi penyinaran berpengaruh terhadap kekerasan permukaan resin komposit nanofilled. Pengaruh durasi penyinaran hanya signifikan apabila jarak tip LED Light Curing Unit terhadap permukaan resin komposit kurang atau sama dengan 5 mm.

Composite resin is a material of choice for direct restorations. Hardening process of composite resin is triggered by light to begin the polymerization process. The aim of this research was to assess the effect of LED light curing unit's tip distance and curing time to surface hardness of nanofilled composite resin. 60 specimens were prepared into a mold and they were divided into 6 groups based on the different curing distance and time which is 2 mm, 5 mm, and 8 mm along with 20 seconds and 40 seconds. The highest surface hardness was seen in group with 2 mm tip's distance and 40 seconds curing time, while the lowest was seen in group with 8 mm tip's distance and 20 seconds curing time. Significant differences were seen between different tip's distances but in 2 groups which has 8 mm tip's distances and different curing time, there is no significant differences. In coclusion, LED light curing unit's tip distance and curing time is affecting surface hardness of nanofilled composite resin. Curing time only affect the surface hardness if the tip's distance is less than 8 mm."
Jakarta: Fakultas Kedokteran Gigi Universitas Indonesia, 2016
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Anggia Nadya Andjani
"Penelitian ini bertujuan untuk mengetahui pengaruh ketebalan resin terhadap depth of cure resin komposit serat sebagai substruktur. Lima belas spesimen dibagi menjadi 3 kelompok ketebalan berbeda: 3, 4, dan 5 mm n=5 . Masing-masing spesimen disinari dengan iradiansi 800 mW/cm selama 20 detik. Hasil penelitian menunjukkan depth of cure kelompok 1 adalah 81 , kelompok 2 adalah 78 dan kelompok 3 adalah 34. Nilai tersebut berbeda bermakna secara statistik melalui uji One-way ANOVA dan Post-hoc. Games-Howell. Disimpulkan bahwa ketebalan mempengaruhi depth of cure resin komposit serat sebagai substruktur.

The aim of this study is to know the effect of resin thickness on the depth of cure of fiber reinforced resin composite as substructure. Fifteen specimens are divided into 3 different thickness groups 3, 4, and 5 mm n 5 . Each specimen was cured with irradiation of 800 mW cm for 20 seconds. The result showed the depth of cure of group 1 was 81 , group 2 78 and group 3 34. The result was significantly different using One way ANOVA and Games Howell Post hoc test. It was concluded that resin thickness has effect on the depth of cure of fiber reinforced resin composit as substructure."
Depok: Fakultas Kedokteran Gigi Universitas Indonesia, 2016
S-Pdf
UI - Skripsi Membership  Universitas Indonesia Library
<<   1 2 3 4 5 6 7 8 9 10   >>