Ryan Rakhmat Setiadi
"Pada penelitian ini, struktur akan dimodelkan beserta tanah disekelilingnya dengan program SAP2000 dimana tanah dimodelkan sebagai linear solid 3D element. Analisis gempa yang digunakan berupa analisa linear time history. Variasi yang model mencakup ketinggian struktur dan juga variasi perletakan, yaitu berupa perletakan jepit dan perletakan tanah dengan nilai modulus elastisitas yang dibeda ? bedakan pada lapisan tanah dimana pondasi berada. Hasil dari penelitian ini diperoleh kesimpulan bahwa efek pengaruh dari SSI tidak terlalu banyak berbeda dengan struktur perletakan jepit baik untuk periode getar struktur maupun respon linear struktur.
In this study, structure will be modeled along with the surrounding soil with finite element program SAP2000, where the soil will be modeled as a linear 3D solid element. Earthquake anaysis used in this study are Linear Time History analysis. Model variations are variations in the height of the structure and variations of boundary condition in the foundation. First variation in boundary are fixed foundation where the building asumming laying in the rock, and the second variation are the soil around the building will be modeled with variations of modulus elasticity. The result of this study concluded that the effect of soilstructure interaction are not too much different from the structure where the fixed foundation asumming, the period of structure and linear response of structure are almost same."
Depok: Fakultas Teknik Universitas Indonesia, 2012
S42973
UI - Skripsi Open Universitas Indonesia Library
Geraldi Othanius Hardymulia
"Terdapat kenaikan permintaan terhadap mobil baru di Indonesia beberapa tahun belakangan ini. Hal ini tentunya sejalan dengan kenaikan permintaan terhadap showroom mobil, sehingga konstruksi showroom mobil menjadi hal yang penting untuk dilakukan. Dalam desain showroom mobil diperlukan suatu sistem struktur yang memiliki bentang lebar pada ruang pertemuan, hall, lobby, dan ruang display. Disinilah post-tensioned (PT) flat slab hadir menyelesaikan permasalahan tadi, karena jenis pelat ini dapat digunakan untuk bentang yang lebih panjang dari struktur beton konvensional sehingga lebih cocok untuk digunakan pada bangunan showroom mobil yang membutuhkan bentang lebar. Pada penelitian ini digunakan studi kasus bangunan showroom mobil dua lantai yang berlokasi di Depok. Metode analisis yang digunakan dalam penelitian ini adalah metode FEM (finite element method) dengan bantuan software ETABS V20 untuk memodelkan struktur bangunannya. Struktur akan dibandingkan respon gempanya menggunakan dua metode analisa gempa dinamik yaitu respon spektrum dan linear time history. Ditemukan bahwa untuk semua respon gempa (story drift, story displacement, story shear, overturning moment), metode respon spektrum memberikan respon yang lebih besar pada kedua arah X dan Y. Untuk perbandingan antara struktur konvensional dan PT flat slab ditemukan bahwa struktur PT flat slab memberikan respon gempa yang lebih besar, dan harga (biaya) material yang lebih murah dibandingkan dengan struktur konvensional.
There has been an increase in demand for new cars in Indonesia in recent years. This trend correlates with the rising demand for car showrooms, making the construction of these showrooms crucial. The design of car showrooms requires a structural system with wide spans for meeting rooms, halls, lobbies, and display areas. This is where post-tensioned (PT) flat slabs come in to solve the aforementioned issues, as these slabs can be used for longer spans compared to conventional concrete structures, making them more suitable for wide-span showroom buildings. In this study, a two-story car showroom located in Depok was chosen as a case study. The analytical method employed in this research is the Finite Element Method (FEM) using ETABS V20 software to model the building structure. The structure's seismic response will be compared using two dynamic earthquake analysis methods: response spectrum and linear time history analysis. It was found that for all seismic responses (story drift, story displacement, story shear, overturning moment), the response spectrum method yields larger responses in both X and Y directions. Comparing conventional structures with PT flat slabs, it was found that PT flat slabs exhibit larger seismic responses but offer cheaper material costs compared to conventional structures."
Depok: Fakultas Teknik Universitas Indonesia, 2024
S-pdf
UI - Skripsi Membership Universitas Indonesia Library
Tambunan, Michael Loreantz Steven
"Dalam penelitian ini dilakukan evaluasi desain seismik berbasis performa pada sebuah struktur laboratorium dengan alternatif sistem lantai konvensional dan alternatif sistem lantai posttensioned flat slab (PTFS). Penelitian dilakukan dengan mengevaluasi hasil desain linier kedua alternatif struktur dengan pendekatan metode pushover analysis dan non-linear time history analysis. Model non-linier dibangun dengan mendefinisikan sendi plastis yang sesuai dengan klausul yang berlaku. Khusus pada model PTFS, dilakukan simplifikasi model analisis menggunakan equivalent beam width. Hasil penelitian ini menunjukkan bahwa hasil desain kedua alternatif struktur sudah memenuhi level performa life safety (LS). Lebih lanjut diketahui performa elemen equivalent beam width pada sistem PTFS masih berada pada level immediate occupancy (IO), menunjukkan sistem struktur posttensioned flat slab masih dapat diterima di wilayah dengan aktivitas seismik yang tinggi bila didesain dan dievaluasi dengan baik.
In this research, a performance-based seismic design evaluation is used to a laboratory building structure with conventional floor system alternative and posttensioned flat slab (PTFS) floor system alternative. The research is conducted by evaluating the resulting linear design of the two alternatives using pushover analysis and non-linear time history analysis. Non-linear models are constructed by defining plastic hinges adhering to building codes. Specific to the PTFS model, simplified analysis model using equivalent beam width is used. The result of this study shows that both structural system alternatives have fulfilled the life safety (LS) performance level. It is further known that the equivalent width model in the PTFS system still complies the immediate occupancy (IO) level, showing that posttensioned flat slab structural system may be acceptable in a high seismic activity with proper design and evaluation procedures. "
Depok: Fakultas Teknik Universitas Indonesia, 2024
T-pdf