Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 3 dokumen yang sesuai dengan query
cover
Rini Rahmasari
"Perilaku perawat tentang self-care behavior yang tepat dibutuhkan untuk mencegah komplikasi akibat pemasangan permanent pacemaker, seyogyanya selalu dilakukan dalam membantu adaptasi pasien dengan permanent pacemaker. Namun, hal tersebut masih didapatkan belum optimal. Oleh karena itu, penelitian ini bertujuan mengidentifikasi faktor-faktor yang memengaruhi perilaku perawat tentang self-care behavior pada pasien terpasang permanent pacemaker. Penelitian ini dilakukan kepada 131 perawat pelaksana di Rumah Sakit Jantung dan Pembuluh Darah Harapan Kita Jakarta dengan menggunakan desain cross sectional, teknik purposive sampling, analisis uji chi square dan regresi logistik berganda. Hasil penelitian menunjukkan bahwa terdapat hubungan signifikan antara pengetahuan perawatan permanent pacemaker dengan perilaku perawat tentang self-care behavior pada pasien terpasang permanent pacemaker (p-value = 0,000; α = 0,05; OR = 20,63). Pengetahuan tentang perawatan permanent pacemaker perlu dilakukan secara berkala untuk meningkatkan perilaku perawat terkait self care behavior pada pasien dengan permanent pacemaker.

Nurses' behavior regarding proper self-care behavior is needed to prevent complications due to the installation of a permanent pacemaker. It should always be done in helping patients adapt to a permanent pacemaker. However, this is still not optimal. Therefore, this study aims to identify the factors that influence nurses' behavior about self-care behavior in patients with permanent pacemaker attached. This research was conducted on 131 nurses at Harapan Kita Heart and Blood Vessel Hospital Jakarta using a cross-sectional design, purposive sampling technique, chi square test analysis and multiple logistic regression. The results showed that there was a significant relationship between knowledge of permanent pacemaker care with nurses' behavior about self-care behavior in patients with permanent pacemaker installed (p-value = 0,000; α = 0.05; OR = 20.63). Knowledge about permanent pacemaker care needs to be done regularly to improve nurse behavior related to self-care behavior in patients with permanent pacemaker."
Depok: Fakultas Ilmu Keperawatan Universitas Indonesia, 2021
T-pdf
UI - Tesis Membership  Universitas Indonesia Library
cover
Simon Salim
"Latar Belakang : Implantasi pacu jantung permanen telah menjadi prosedur umum saat ini. Tujuan tindakan pemasangan pacu jantung permanen tidak lagi hanya sebatas morbiditas dan mortalitas, tetapi juga kualitas hidup. Dalam menilai kualitas hidup dibutuhkan kuesioner yang dapat merubah sesuatu yang kualitatif menjadi data kuantitatif. Kuesioner kualitas hidup yang ada saat ini belum ada yang berbahasa Indonesia. Untuk dapat digunakan dalam menilai kualitas hidup di Indonesia perlu adaptasi bahasa dan budaya. Selain itu, kuesioner terjemahan tersebut harus memiliki validitas dan reliabilitas yang baik. Metode : Studi ini adalah studi cross sectional yang terbagi dalam 2 tahap. Tahap awal berupa adaptasi bahasa dan budaya untuk dapat menghasilkan kuesioner SF-36 dan Aquarel berbahasa Indonesia. Tahap akhir berupa uji validitas dan reliabilitas kuesioner SF-36 dan Kuesioner Aquarel. Subjek berjumlah 30 orang pada tahap awal, dan 20 orang pada tahap akhir. Subjek merupakan pasien dengan pacu jantung permanen, yang kemudian akan dilakukan Tes Jalan 6 Menit (6MWT) dan pemeriksaan NT pro-BNP. Validitas SF-36 dinilai berdasarkan nilai korelasi Kuesioner dengan pemeriksaan penunjang, dan validitas Aquarel dinilai berdasarkan nilai korelasi kuesioner Aquarel dengan Kuesioner SF-36, dan korelasi kuesioner dengan pemeriksaan penunjang. Reliabilitas kuesioner dinilai berdasarkan konsistensi internal dan repeatabilitas. Hasil : Kuesioner SF-36 berbahasa Indonesia memiliki korelasi positif antara 6MWT dengan domain PF (Physical Functioning) (r= 0,363; p=0,001), dan memiliki korelasi negatif antara NT Pro-BNP dengan domain GH (General Health) (r= 0,269; p = 0,020) dan MH (Mental Health) (r= -0,271; p = 0,019). Kuesioner Aquarel berbahasa Indonesia memiliki korelasi positif antara 6MWT dengan domain dyspneu (r=0,228; p=0,048), dan memiliki korelasi negatif antara NT proBNP dengan Domain Chest Discomfort (r = -0.231; p = 0.043) dan Dyspneu (r = 0.268; p = 0.020). Kedua kuesioner SF-36 berbahasa Indonesia (Cronbach α = 0.789) dan Aquarel berbahasa Indonesia (Cronbach α = 0.728) memiliki reliabilitas dan repeatabilitas yang baik. Kesimpulan : Pada proses adaptasi bahasa dan budaya tidak terdapat modifikasi yang berarti pada kedua kuesioner dan dapat diterima baik oleh pasien. Kuesioner SF-36 berbahasa Indonesia dan Kuesioner Aquarel berbahasa Indonesia bersifat valid dan reliable.

acemaker implantation has became common procedure in the last decades. The goal of our therapy was no longer about morbidity and mortality, but quality of life. In assessing the quality of life, we need a questionnaire that can change qualitative value to quantitative value. There is no quality of life questionnaires in Bahasa Indonesia, therefore we need language and cultural adaptation before we can use it in Indonesia. Moreover the translation questionnaire must has good validity and good reliability. We choose SF-36 as generic health related quality of life (HRQoL), as it is the most popular HRQoL questionnaire. Specifically for pacemaker patients, we choose Aquarel Questionnaire. Methods : This cross sectional study was divided into 2 steps. The first step was language and cultural adaptation to create SF-36 and Aquarel questionnaire in Bahasa Indonesia. The final step was validation and reliability test of the translated questionnaire. The subjects were 30 people for the first step , and 20 people for the final step. All the subject were patient with permanent pacemaker. We also conduct two diagnostic tests (6 Minutes Walk Test (6MWT) and NT pro-BNP). SF-36 validity was assessed by its correlation with diagnostic tests, and Aquarel validity was assessed by its correlation with SF-36 and with The diagnostic tests. Both questionnaire reliability assessed by its Internal consistency and repeatability. Results : Our indonesian version of SF-36 shows positive correlation between 6MWT and PF (Physical Functioning) ( r = 0.363 ; p = 0.001) and negative correlation between NT Pro-BNP value with GH (General Health) (r = -0.269; p = 0.020) and MH (Mental Health) (r = -0.271; p = 0.019). Our Indonesian version of Aquarel shows positive correlation between 6MWT with Dyspneu domain ( r = 0.228 ; p = 0.048 ) and shows negative correlation between NT Pro-BNP with Chest Discomfort (r = -0.231; p = 0.043) and Dyspneu (r = -0.268; p = 0.020). Both the Indonesian SF-36 (Cronbach ? = 0.789) and the Indonesian Aquarel (Cronbach ? = 0.728) shows good reliability and repeatability. Conclusions : We succed doing language and cultural adaptation of SF-36 and Aquarel questionnaire. Both Indonesian version questionnaire are valid and reliable .
"
Fakultas Kedokteran Universitas Indonesia, 2015
T55664
UI - Tugas Akhir  Universitas Indonesia Library
cover
Muhammad Rusydi
"Latar Belakang : Deteksi adanya penyakit jantung koroner PJK pada pasien bradikardi simptomatik yang memerlukan pemasangan pacu jantung permanen perlu diketahui secara dini. Saat ini penggunaan modalitas canggih seperti kateterisasi jantung dan CT kardiak menjadi pilihan utama dalam deteksi adanya PJK pada pasien blok nodus atrioventrikular AV total namun dengan risiko dan biaya yang masih relatif mahal. Gambaran fragmentasi kompleks QRS fQRS pada elektrokardiografi berkaitan dengan adanya jaringan parut atau iskemia pada miokard, namun belum ada studi sebelumnya yang menghubungkan fQRS dengan PJK pada pasien blok nodus AV total yang akan dilakukan pemasangan pacu jantung permanen. Tujuan : Mengetahui hubungan antara fragmentasi kompleks QRS dengan penyakit jantung koroner pada pasien dengan blok nodus AV total yang memerlukan pemasangan pacu jantung permanen. Metode : Penelitian ini merupakan studi analitik kasus kontrol dengan menggunakan data sekunder rekam medis pasien blok nodus AV total yang sudah dilakukan tindakan pemasangan pacu jantung permanen dan angiografi koroner di Rumah Sakit PJN Harapan Kita. Penelitian dilakukan pada bulan April-Agustus 2017. Dilakukan pencatatan karakteristik pasien, faktor-faktor yang diketahui mempengaruhi kejadian PJK serta hasil pemeriksaan ekokardiografi dan angiografi koroner. Pembacaan ekg dilakukan oleh dua orang spesialis jantung dan pembuluh darah konsultan di divisi aritmia. Hasil : Total sampel penelitian ini adalah 46 sampel yang terdiri atas 23 kasus dan 23 kontrol. Gambaran fQRS pada pasien blok nodus AV total menunjukkan kecenderungan 2,4 kali mengalami PJK dibandingkan dengan yang tanpa fQRS, walaupun secara statistik memperlihatkan hasil yang tidak bermakna OR = 2,4; p = 0,236 . Hasil uji Kappa menunjukkan kesepakatan yang baik kedua observer dengan nilai Kappa inter-observer 0,487 serta intra-observer 0,737 dan 0,783. Kesimpulan : Fragmentasi kompleks QRS pada pasien blok nodus AV total memiliki kecenderungan 2,4 kali untuk prediksi PJK namun tidak bermakna secara statistik.Kata Kunci : Fragmentasi kompleks QRS, penyakit jantung koroner, blok nodus AV total, pacu jantung permanen

Background Detection of coronary artery disease CAD in symptomatic bradycardia patients requiring permanent pacemaker implantation should be known early. Currently the use of advanced modalities such as cardiac catheterization and cardiac CT are the primary choice in detection of CAD in total atrioventricular blok patients with relatively high cost and risk. The description of fragmented QRS complex fQRS in electrocardiography associated with the presence of ischemia or scar in the myocardium that can be an alternative detection of CAD in patients with total AV block requiring permanent pacemaker implantation. Objectives To determine the relationship between fragmented QRS complex and coronary artery disease in patients with complete atrioventricular AV nodal block requiring permanent pacemaker implantion. Methods This study is an analytic study of case control using secondary data of medical record of complete AV block patients who have performed permanent pacemaker and coronary angiography at PJN Harapan Kita hospital. The study was conducted in April Agustus 2017. Recorded patient characteristics, factors known to influence CAD events as well as results of echocardiography and coronary angiography. The EKG readings were performed by two cardiologist consultants in the arrhythmia division. Results The total sample of this study was 46 consisting of 23 case and 23 control. The description of Fqrs in patients with total AV nodal block showed a trend of 2.4 times for CAD prediction compared with those without Fqrs, although statistically showed a non significant OR 2.4 p 0.236 . Kappa test results showed good agrreement both observers with Kappa inter observer value 0.487 and intra observer 0.737 and 0.783. Conclusion Fragmented QRS complex in patients with complete AV nodal block had a tendency of 2.4 times for CAD prediction but statistically not significant. "
Jakarta: Fakultas Kedokteran Universitas Indonesia, 2017
SP-pdf
UI - Tugas Akhir  Universitas Indonesia Library