Hasil Pencarian

Ditemukan 55 dokumen yang sesuai dengan query
cover
Siti Mutmainnah
Abstrak :
Planning Target Volume (PTV) merupakan area treatment radioterapi yang diperoleh dengan melakukan penambahan margin pada Clinical Target Volume (CTV). Margin tersebut merupakan kompensasi dari ketidakpastian geometri yang terjadi pada saat treatment. Nilai margin diperoleh dari data online On-Board Imaging (OBI) match result 26 pasien kanker serviks yang mendapatkan penanganan dengan mesin linac Halcyon di RSUPN Dr. Cipto Mangunkusumo. Data OBI dalam arah vertikal (anterior-posterior), longitudinal (cranial-caudal), dan lateral (left-right) digunakan untuk menghitung kesalahan pengaturan, yakni berupa kesalahan sistematik dan acak sebagai variabel dari formulasi Stroom dan Van Herk. Berdasarkan formula Stroom, diperoleh nilai margin sebesar 1 cm untuk arah vertikal dan longitudinal, serta 1,6 cm untuk arah lateral. Sedangkan formula Van Herk, yaitu 1,2 cm untuk arah vertikal, 1,1 cm untuk arah longitudinal, dan 1,9 cm untuk arah lateral. Hasil tersebut menunjukkan nilai yang jauh lebih besar dibandingkan dengan margin yang digunakan pada approved treatment plan yaitu 0,7 cm untuk segala arah. Evaluasi dilakukan dengan cara pengonturan ulang PTV dan planning ulang pada 4 kasus pasien. Hasil penelitian ini menunjukkan bahwa dosis yang diterima target pada approved treatment plan lebih baik dibandingkan target yang menggunakan margin Stroom dan Van Herk. Hal ini dikarenakan nilai margin yang lebih besar berisiko mengenai organ lebih banyak, sehingga optimasi yang dilakukan harus lebih optimal agar organ at risk (OAR) menerima dosis serendah mungkin sesuai dengan constraint guidelines menurut QUANTEC. ......Planning Target Volume (PTV) is a radiotherapy volume concepts that obtained by adding margin to the Clinical Target Volume (CTV). The margin is a compensation for geometric uncertainty that occurs during treatment. PTV margin was obtained from online data on On-Board Imaging (OBI) match results of 26 cervical cancer patients treated with the Halcyon Linac machine in RSUPN. Dr. Cipto Mangunkusumo. OBI data in the vertical (anterior-posterior), longitudinal (cranial-caudal), and lateral (left-right) axis used to count setup errors, namely systematic and random errors, variables from the Stroom and Van Herk formulations. Based on the Stroom formula, the margin values ​​are 1 cm for the vertical and longitudinal axis, and 1.6 cm for the lateral axis. On the other hand, the margin from Van Herk formula was 1.2 cm for the vertical axis, 1.1 cm for the longitudinal axis, and 1.9 cm for the lateral axis. These results are larger than the margin in approved treatment plan, which is 0.7 cm for all axis. We evaluated the dosimetric difference by re-contouring PTV and replanning 4 cases of the treated patients. This study indicate that the dose received by the target in the approved treatment plan is better than the target using Stroom and Van Herk margins. That cause a large margin has a bigger risk of affecting more normal tissue area. Therefore, optimization must be more optimal to reduce organ at risk (OAR) dose as low as possible according to QUANTEC constraint guidelines.
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2022
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Khaerunnisa
Abstrak :
ABSTRAK
Film EBT3 merupakan model film radiochromic yang didisain khusus untuk keperluan radioterapi eksternal (external beam therapy, EBT) respon film terhadap radiasi pengion mengakibatkan perubahan pada spektrum serapan dan sifat optiknya membuat film radiochromic menjadi pilihan yang banyak digunakan dalam bidang oncologi. Respon film terhadap radiasi biasanya diukur dalam hal perubahan kerapatan optik (netOD) yang nilainya bergantung dari banyaknya berkas yang melewati film dan juga panjang gelombang cahaya dari alat pembaca (densitometer optik). Penelitian ini bertujuan menyelidiki pengaruh penggunaan densitometer optik yang berbeda, yakni scanner, densitometer dan spektrofotometer dalam mengukur respon dosimeter film terhadap radiasi pengion. Penyelidikan respon film dilakukan dengan mengirradiasi film menggunakan pesawat Linac Varian Trilogy dengan energi 6 MV. netOD yang terbaca pada film dilakukan dengan mengekstrak mean pixel value dari kanal merah ketika menggunakan scanner. Ketika menggunakan densitometer netOD dihasilkan dari perubahan nilai OD yang terbaca secara langsung. Sedangkan nilai netOD didapat dengan melihat perubahan spektrum serapan film sesudah dan sebelum irradiasi menggunakan spektrofotometer. Evaluasi penggunaan metode dosimetri dilakukan menggunakan fantom homogen untuk evaluasi dosis uji dan juga untuk evaluasi pada variasi lapangan penyinaran, dan fantom non-homogen (rando) untuk implementasi metode pada perlakuan klinis radioterapi. Untuk mendapatkan hasil pengukuran yang optimum juga dilakukan penyelidikan karakteristik spektrum serapan pada variasi level dosis dan variasi waktu pengukuran pasca irradiasi. Hasil pengukuran respon film menunjukkan tidak terjadi perubahan pita serapan film terhadap perubahan level dosis ataupun terhadap perubahan waktu pasca irradiasi, yakni berada pada pusat pada panjang gelombang 635 nm untuk pita serapan maksimum, dan pita serapan ke-dua berpusat pada 583 nm. Penyelidikan sensitivitas ketiga metode menghasilkan tren kurva sensitivitas yang mirip namum memiliki besar yang berbeda dimana sensitivitas tertinggi didapat ketika menggunakan spektrofotometer. Sementara ketidakpastian (1σ) netOD untuk ketiga metode menghasilkan nilai ketidakpastian yang cukup besar untuk dosis dibawah 100 cGy dan nilai ketidakpastian mulai membaik ketika level dosis meningkat. Pada aplikasi klinis ketiga metode dosimeteri dievaluasi dengan melihat besar diskrepansi yang dihasilkan pada adaerah target kepala, paru-paru dan prostat. Penggunaan scanner dan spektrofotometer menghasilkan rata-rata diskrepansi dibawah 2% untuk semua target pengukuran, sedangkan densitometer menghasilkan rata-rata diskrepansi sampai 3%.
ABSTRACT
EBT3 film is a radiochromic film model specially designed for external radiotherapy (EBT). The response of the film to ionizing radiation results in changes in the absorption spectrum and its optical properties making radiochromic films a widely used choice in oncology. The response of the film to radiation is usually measured in terms of the change in optical density (netOD) whose value depends on the number of beams passing through the film and also the wavelength of light from the reader (optical densitometer). This study aims to investigate the effect of using different optical densitometers, namely scanners, densitometers and spectrophotometers in measuring the response of film dosimeters to ionizing radiation. The investigation of the film response was carried out by irradiating the film using a Linac Varian Trilogy with an energy of 6 MV. The netOD read on the film was done by extracting the mean pixel value from the red channel when using a scanner. When using a densitometer the netOD results from changes in OD values that are read directly. While the netOD value was obtained by measuring changes in the absorption spectrum of the film after and before irradiation using a spectrophotometer. Evaluate the use of the dosimetric methods was carried out using homogeneous phantom for the evaluation of test doses and also for evaluation of variations in the radiation field, and non-homogeneous phantom (rando) for the implementation of the method in clinical radiotherapy treatment. To obtain the optimum measurement results, an investigation of the characteristics of the absorption spectrum was also carried out at variations in dose levels and variations in measurement time after irradiation. The results of the measurement of the response of the film showed that there was no change in the absorption band of the film due to changes in dose levels or to changes in time after; irradiation, which was at the center at a wavelength of 635 nm for the maximum absorption band, and the second absorption band was centered at 583 nm. The sensitivityinvestigation of the three methods resulted in a trend of similar sensitivity curves but different magnitudes with the highest sensitivity obtained when using a spectrophotometer. Meanwhile, the uncertainty (1σ) netOD for the three methods resulted in a fairly large uncertainty value for doses below 100 cGy and the uncertainty value began to decrease as the dose level increased. In clinical application, the three dosimetric methods were evaluated by measuring the resulting discrepancy in the target areas of the head, lungs and prostate. The use of a scanner and a spectrophotometer resulted in an average discrepancy of below 2% for all measurement targets, while the use of a densitometer resulted in an average discrepancy of up to 3%.
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2020
T-pdf
UI - Tesis Membership  Universitas Indonesia Library
cover
Didin
Abstrak :
Halcyon 2.0 memiliki EPID yang dapat digunakan untuk Patient-Specific Quality Assurance (PSQA) dan selalu merekam dosis transit selama penyinaran. PSQA merupakan metode untuk menilai kesesuaian hasil perencanaan radioterapi dengan pengukuran, sedangkan dosis transit memiliki kaitan terhadap distribusi dosis pasien. Penelitian ini menganalisis hasil PSQA pada Halcyon 2.0 dan dosis transit setiap fraksi pada kasus nasofaring, servik, dan payudara. Analisis dilakukan berdasarkan metode pengukuran dan evaluasi yang direkomendasikan TG-218. Selain itu, analisis dosis transit dilakukan pada setiap fraksi dan fluence map fraksi pertama dijadikan sebagai baseline. Nilai tolerance limit dan action limit Halcyon 2.0 memenuhi kriteria dari TG-218. Metode dan kriteria gamma index yang direkomendasikan TG-218 memiliki performa baik. Berbeda hal, nilai GPR dosis transit kasus nasofaring terjadi penurunan lebih curam dibandingkan kasus servik dan payudara, hal yang sama untuk korelasi berat badan dengan GPR. Penurunan GPR dari memiliki korelasi dengan berat badan, terutama untuk kasus nasofaring. Selain itu, kasus payudara tidak memiliki subjek dengan korelasi signifikan (p < 0,05) antara GPR dengan berat badan. Kesimpulan dari penelitian ini, berdasarkan metode TG-218 Halcyon 2.0 memiliki hasil PSQA yang baik. Nilai GPR untuk ketiga kasus mengalami penurunan seiring bertambahnya waktu dan memiliki kaitan terhadap berat badan. ......Halcyon 2.0 has an EPID that can be used for Patient-Specific Quality Assurance (PSQA) and continuously records transit doses during irradiation. PSQA is a method for assessing the suitability of the results of radiotherapy planning with measurements, while the transit dose has a bearing on the patient's dose distribution. This study analyzed PSQA results on Halcyon 2.0 and transit doses for each fraction in the nasopharynx, cervix, and breast cases. The analysis was carried out based on the measurement and evaluation methods recommended by TG-218. In addition, transit dose analysis was carried out for each fraction, and the fluence map of the first fraction was used as a baseline. The tolerance limit and action limit values of Halcyon 2.0 meet the criteria of TG-218. The method and gamma index criteria recommended by TG-218 have good performance. In contrast, the transit dose GPR values for nasopharyngeal cases decreased more steeply than cervical and breast cases, the same for the correlation of body weight with GPR. The decrease in GPR correlates with body weight, especially for nasopharyngeal cases. In addition, no breast cases had a significant correlation (p <0.05) between GPR and body weight. The conclusion of this study, based on the TG-218 Halcyon 2.0 method, has good PSQA results. The GPR values for the three cases decreased over time and were related to body weight.
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2022
T-pdf
UI - Tesis Membership  Universitas Indonesia Library
cover
Rafika Fitria Puspasari
Abstrak :
Kalibrasi berkas radiasi di beberapa rumah sakit di seluruh dunia membutuhkan validasi sehingga dapat memverifikasi dosis radioterapi bahwa telah sesuai dengan preskripsi dosis. Verifikasi terhadap dosis yang dihasilkan oleh mesin radioterapi bertujuan untuk mereduksi ketidakpastian dalam melakukan perawatan ke pasien kanker dan mencegah terjadinya kesalahan radiasi sehingga dapat memberikan perawatan terbaik ke pasien. Pendekatan umum dari IAEA untuk verifikasi keluaran dosis adalah TLD dikirimkan ke institusi untuk dilakukan penyinaran. Pengukuran dosis untuk berkas foton pada kondisi referensi, menggunakan sistem TLD dengan protokol TRS 398. Sepuluh buah TLD disinari masing-masing dengan dosis sebesar 2 Gy di dalam air dengan 10 buah TLD sebagai kontrol. Penyinaran untuk mendapatkan dosis absorbsi juga dilakukan pada ionisasi chamber pada posisi TLD sesuai dengan protokol IAEA Technical Reports Series No. 398 (TRS-398). Pengukuran dilakukan pada kondisi referensi menggunakan holder standar IAEA di phantom air dengan volume 30 cm x 30 cm x 30 cm, kedalaman di air 10 cm, luas lapangan 10 cm x 10 cm serta menggunakan pengaturan SSD yang dipakai di klinis. Enam pusat kanker dengan tujuh akselerator linier energi ganda dan satu energi tunggal berkontribusi dalam pengukuran ini. TLD disediakan oleh departemen fisika sebagai dosimeter independen dan kemudian dibandingkan dengan ionisasi chamber. Persentase penyimpangan dosis antara TLD dan ionisasi chamber dilakukan dalam pengukuran ini. Terdapat tujuh dari 15 pengukuran (46,67%) berada di batas optimal ± 2,5%, delapan pengukuran di batas toleransi ± 3% dimana lima pengukuran berada di atas batas tolerensi yang ditentukan oleh IAEA. Selisih rata-rata antara pengukuran dosis keluaran Linac yang dilakukan oleh IAEA dan penelitian ini adalah 1,96% untuk 6 MV dan 2,56% untuk 10 MV. Hasil pengukuran dosis keluaran Linac pada penelitian ini didistribusikan sebagai rasio dengan rata-rata sebesar 0,96 ± 0,06. ......Radiation beam calibration in several hospitals around the world requires validation so that it can verify that the radiotherapy dose is in accordance with the dosage prescription. Verification of the dose produced by the radiotherapy machine aims to reduce uncertainty in treating cancer patients and prevent radiation errors so that they can provide the best care for patients. The IAEA’s general approach for output verification is for the TLD to be sent to the institution for irradiation. Dose measurements for photon beams at reference conditions, using the TLD system with the TRS 398 protocol. Ten TLDs were irradiated with a dose of 2 Gy each in water with 10 TLDs as controls. Irradiation to obtain the absorbed dose was also carried out in the ionization chamber at the TLD position according to the IAEA Technical Reports Series No. protocol. 398 (TRS-398). Measurements were carried out at reference conditions using IAEA standard holders in phantom water with a volume of 30 cm x 30 cm x 30 cm, depth in water 10 cm, field area 10 cm x 10 cm and using the SSD setting used in clinical practice. Six cancer centers with seven dual-energy and one single-energy linear accelerator contributed to this measurement. The TLD was provided by the physics department as an independent dosimeter and then compared to the ionization chamber. The percentage deviation of the dose between the TLD and the ionization chamber is carried out in this measurement. There are seven out of 15 measurements (46.67%) which are within the optimal limit of ± 2.5%, eight measurements were within the ±3% tolerance limit of which five measurements were above the tolerance limit specified by the IAEA. The mean difference between Linac output dose measurements performed by the IAEA and this study was 1.96% for 6 MV and 2.56% for 10 MV. The results of Linac output dose measurements in this study were distributed as a ratio with an average of 0.96 ± 0.06.
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2022
T-pdf
UI - Tesis Membership  Universitas Indonesia Library
cover
Allam Ubaidillah
Abstrak :
Pemanfaatan CBCT (Cone Beam Computed Tomography) radioterapi adaptif dipengaruhi oleh paremeter akuisisi dan rekonstruksi citra dalam akurasi kalkulasi dosis dan kualitas citra dipelajari dalam penelitian ini. Kurva kalibrasi dihasilkan melalui pemindaian fantom CIRS menggunakan CBCT XVI Elekta 5.0.4 dan CT Simulator Somatom, yang bekerja sebagai citra CT referensi. Fantom Rando dan Catphan dipindai dengan parameter akuisisi dan rekonstruksi yang sama untuk menguji akuasi kalkulasi dosis dan kualitas citra. Pengujian kualitas citra sesuai panduan modul XVI Image Quality Test. Parameter akuisisi dan rekonstruksi memiliki dampak pada nilai HU yang digunakan dalam kurva kalibrasi HU-RED. Perbedaan dosis untuk seluruh kurva kalibrasi di bawah 1% dan lolos kriteria gamma passing rate. Citra yang menggunakan 120 kVp, F1 (dengan Filter Bowtie), dan 50 mA (F1-120-50-10) menghasilkan skor GI tertinggi 98,5%. Pengujian kualitas citra menghasilkan skor sebesar 1,2% pada uji uniformitas, 2.14% pada uji low contrast visibility, dan 11 lp/cm pada tes resolusi spasial. Dengan, protokol rekonstruksi yang berbeda menunjukan skor 3,83% dan 4 lp/cm dalam pengujian low contrast visibility dan resolusi spasial, secara berturut-turut. Parameter rekonstruksi CBCT bekerja sebagai koreksi hamburan (scatter correction). Hal ini meningkatkan akurasi dosis dan kualitas citra. Protokol akuisisi CBCT yang tidak cocok menghasilkan citra dengan ketidakpastian tinggi dan protokol rekonstruksi tidak bisa memperbaikinya. Protokol F1-120-50-10 menghasilkan akurasi dosis dan kualitas citra tertinggi. ......The impact of the modified image acquisition and preset reconstruction parameter available in XVI on improving CBCT image quality and dose calculation accuracy were evaluated. Calibration curves were generated by scanning the CIRS phantom using CBCT XVI Elekta 5.0.4 and CT Simulator Somatom, that served as CT image reference. Rando and Catphan phantom were scanned with same acquisition and reconstruction parameters for dose accuracy and image quality tests. The image quality test is uniformity, low contrast visibility, spatial resolution, and geometrical scale test for each image by following the XVI image quality test module. Acquisition and reconstruction parameters have an impact on the HU value that is used as the HU-RED calibration curve. The dose difference for all the calibration curves was within 1% and passed the gamma passing rate. Images acquired using 120 kVp, F1 (with Bowtie Filter), and 50 mA (F1-120-50-10) scored the highest GI of 98.5%. It also scored 1.20% on the uniformity test, 2.14% on the low contrast visibility test, and 11 lp/cm on the spatial resolution test. However, using different reconstructions the score is 3.83% and 4 lp/cm in contrast and spatial resolution test, respectively. Reconstruction protocls work as a scatter correction. It could improve the dose accuracy and image quality. Nevertheless, without adequate CBCT acquisition protocols, it would produce an image with high uncertainty and cannot be fixed with reconstruction protocols. The F1-120-50-10 protocols generate the highest dose accuracy and image quality.
Depok: Fakultas Matematika Dan Ilmu Pengetahuan Alam Universitas Indonesia, 2023
T-pdf
UI - Tesis Membership  Universitas Indonesia Library
cover
Ahcdriany
Abstrak :
Prospek penggunaan kurva kalibrasi dalam perhitungan dosis antar modalitas menjadi tantangan baru dalam penggunaan film gafchromic EBT3. Tujuan utama penelitian ini adalah membandingkan hasil perhitungan dosis pada pesawat brakhiterapi sumber Ir-192 dan Co-60 dengan menggunakan fungsi kalibrasi pada brakhiterapi Ir-192, brakhiterapi Co-60, teleterapi LINAC 6 MV dan Co-60. Pengukuran dilakukan dengan melakukan kalibrasi pada keempat modalitas menggunakan film gafchromic EBT3. Hasil kalibrasi berupa fungsi kalibrasi digunakan dalam mengkonversi densitas optik pada hasil perencanaan dengan dosis perskripsi 2 Gy, 3 Gy dan 6 Gy pada tiga buah aplikator silinder dengan fantom akrilik pada kedalaman 5 mm, 6 mm dan 7 mm. Hasil menunjukkan kurva kalibrasi keempat modalitas tampak hampir berimpit dengan pola polinomial. Koefisien korelasi R2 pada modalitas menunjukkan linearitas kalibrasi berturut-turut sebersar 0,9991; 0,9989; 0,9981 dan 0,990. Nilai dosis terukur tampak berkuran pada jarak yang lebih besar dari pusat aplikator ke fantom. Hasil perhitungan gamma indeks bernilai lebih kecil pada toleransi yang lebih kecil dengan nilai minimum dan maksimum sebesar 74% dan 98,4%. ......The prospect of using calibration curves in calculating intermodality doses is a new challenge in the use of EBT3 gafchromic films. The main objective of this study was to compare the dose calculations on the Iridium (Ir)-192 and Cobalt (Co)-60 brachytherapy by using the calibration function of Ir-192 brachytherapy, LINAC 6 MV, Co-60 brachytherapy, and Co-60 teletherapy. The calibration functions were obtained from the exposure of the EBT3 gafchromic film with dose references of 0 to 10 Gy by using the calibration function of Ir-192 brachytherapy, LINAC 6 MV, Co-60 brachytherapy, and Co-60 teletherapy. The dose references of the treatment planning system (TPS) were 2 Gy, 3 Gy and 6 Gy. The experiment was conducted with three cylindrical applicators. R2 of the LINAC 6 MV, Ir-192 brachytherapy, Co-60 brachytherapy, and Co-60 teletherapy are about 0.9991, 0.9989, 0.9981 and 0.990 respectively. The use of the Co-60 teletherapy calibration function shows the greatest discrepancy. Measured dose values ​​appear to be reduced at a greater distance from the center of the applicator to the phantom. The results of the calculation of the gamma index are smaller at a smaller tolerance. The minimum and maximum value of 74% and 98.4% respectively.
Depok: Fakultas Matematika Dan Ilmu Pengetahuan Alam Universitas Indonesia, 2023
T-pdf
UI - Tesis Membership  Universitas Indonesia Library
cover
Cica Yulinar
Abstrak :
Dalam kalibrasi keluaran berkas elektron linear accelerator (LINAC) medis mengikuti protokol TRS-398 IAEA atau AAPM TG-51. Pada tahun 2020, muncul penelitian tentang modifikasi kalibrasi keluaran berkas elektron, didapatkan hasil bahwa modifikasi kalibrasi tersebut memiliki ketidakpastian yang lebih rendah daripada protokol AAPM TG-51. Kemudian, sebagai pembanding telah dilakukan penerapan modifikasi kalibrasi keluaran berkas elektron berdasarkan TRS-398 dan memberikan hasil yang masih di bawah toleransi yang diperbolehkan. Pada penelitian ini akan dilakukan penerapan modifikasi kalibrasi dan dibandingkan dengan protokol AAPM TG-51 dan TRS-398. Kalibrasi berkas elektron dilakukan pada energi 6, 8, 10, 12, dan 15 MeV dari Linear Accelerator Elekta Synergy Platform dan Versa HD. Bacaan muatan akan dihitung oleh kamar ionisasi PTW 30013, IBA CC13, and Exradin A11. Dosis di kedalaman referensi dihitung dengan tiga metode, sesuai dengan AAPM TG 51, TRS 398, dan menggunakan modifikasi kalibrasi keluaran berkas elektron. Dosis di kedalaman maksimum dinyatakan dalam dosis per monitor unit (cGy/MU). Rata-rata rasio dosis serap menggunakan modifikasi kalibrasi dan TRS-398 adalah 1,004. Rata-rata rasio dosis serap menggunakan modifikasi kalibrasi dan TG-51 adalah 1,009. Hasil tersebut di bawah batas toleransi (±2%) berdasarkan IAEA TRS-398. ......The electron beam output calibration follows the IAEA TRS-398 or AAPM TG-51 protocols. Muir proposed electron beam dosimetry modification and provided a lower deviation than AAPM TG-51. The modified calibration was applied based on TRS-398 and obtained results still below the permissible tolerance. This study aimed to compare the absolute calibration output based on IAEA TRS-398, AAPM TG-51, and modified calibration. Beam calibration at energies of 6, 8, 10, 12, and 15 MeV were carried out with Synergy Platform and Versa HD linear accelerator. Charge reading measurement is obtained using ionization chamber PTW30013, IBACC13, and ExradinA11. Electron beam dosimetry follows the AAPM TG-51, TRS-398, and modified calibration were performed to measure the dose at the maximum depth and expressed in dose/monitor unit (cGy/MU). The average absorbed dose ratio using the modified calibration and TRS-398 is 1,004. The average absorbed dose ratio using the modified calibration and TG-51 is 1,009. The results are below the tolerance limit (±2%) based on IAEA TRS-398.
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2022
T-pdf
UI - Tesis Membership  Universitas Indonesia Library
cover
Brigitha Dwinesti
Abstrak :
Intensity Modulated Radiotherapy (IMRT) adalah teknik radioterapi yang kompleks, sehingga verifikasi independen atau audit dosimetri harus dilakukan untuk memastikan bahwa dosis yang akurat diberikan kepada pasien. Penelitian ini melakukan audit multicenter dengan menggunakan metode audit dosimetri yang dikembangkan dari audit dosimetri IAEA untuk IMRT/VMAT. Fantom dalam penelitian ini terbuat dari bahan akrilik dengan dua struktur insert: planning target volume (PTV) berbentuk C dan organ at risk (OAR). Citra fantom diambil dengan CT simulator milik centre, kemudian perencanaan radiasi dibuat dengan dosis PTV 4 Gy/2 fraksi (D95% = 95%, D2% < 107%, dan Dmax < 110%) dan dosis OAR maksimum 2,8 Gy. Evaluasi dosis pada penelitian ini menggunakan TLD-rod untuk dosis titik dan Gafchromic Film EBT3 untuk distribusi dosis 2D. Evaluasi gamma dilakukan untuk distribusi dosis film dengan kriteria 3%/3mm dan 3%/2mm. Audit dosimetri IMRT menggunakan fantom C-shape dilakukan di tujuh linac (dynamic MLC dan static MLC) dari enam centre di Jakarta. Hasil TLD untuk dosis poin PTV dan OAR menunjukkan bahwa semua 12 IMRT plan memenuhi toleransi deviasi ±5%. Evaluasi EBT3 film mengidentifikasi bahwa hampir semua plan memiliki pass rate diatas 95% untuk kriteria 3%/3mm dan diatas 90% untuk 3%/2mm. Tiga rencana dari tiga centre juga dibandingkan dengan data studi sebelumnya dari pusat yang sama. ......Intensity Modulation Radiation Therapy (IMRT) is a complex radiotherapy technique, so independent verification or dosimetry audits must be performed to ensure that accurate dosing is delivered to patients. This study conducted a multicenter audit using a dosimetry audit method developed from the IAEA dosimetry audit for IMRT/VMAT. The phantom in this study is made of acrylic material with two insert structures: planning target volume (PTV) and organ at risk (OAR). Phantom was scanned with a CT simulator at each hospital, and dose distribution was simulated with a PTV prescription dose of 4 Gy/2 fraction (D95% = 95%, D2% < 107%, and Dmax < 110%) and a maximum OAR dose of 2.8 Gy. Dose evaluation in this study used TLD-rod for point dose and Gafchromic Film EBT3 for 2D dose distribution. Gamma evaluation was performed for film dose distribution with 3%/3mm and 3%/2mm criteria. The IMRT dosimetry audit using a C-shape phantom was tested in seven linacs (dynamic and static MLC) from six centres in Jakarta. The TLD results for PTV and OAR point dose show that all 14 IMRT plans meet deviation tolerance within ±5%. The film EBT3 evaluation identified that almost all plans pass the minimum 95% gamma passing rate for 3%/3mm criteria and the minimum of 90% for 3%/2mm. Three plans from three centres were also compared to the previous study data from the same centres.
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2024
T-pdf
UI - Tesis Membership  Universitas Indonesia Library
cover
Isnaini Nur Islami
Abstrak :
Sistem respiratory gating memiliki peran dalam pengobatan kanker pada area intrafraction motion. Sistem respiratory gating non-invasive umumnya menggunakan surrogate target pada permukaan tubuh pasien, yang dapat memberikan peningkatan dosis permukaan dan ketidaknyamanan pasien. Penelitian ini merupakan studi rancang tahap awal sistem gating berbasis laser tanpa adanya kontak pada pasien yang dapat mendeteksi pergerakan pernapasan. Sistem ini dikontruksi menggunakan laser Leuze dengan holder stand in-house menggunakan stepper motor untuk posisi sudut laser dan skrip program python sederhana untuk monitoring sistem napas menjadi trigger data beam on-off. Sistem ini diverifikasi melalui kalibrasi menggunakan phantom Anzai dan CIRS, menunjukkan kesalahan rata-rata sebesar 0,94±0,75% dan koefisien korelasi kalibrasi amplitudo rata-rata sebesar 0,975±0,004. Sistem ini divalidasi pula terhadap sistem klinis Anzai AZ-733V dan real-time position management (RPM) sebagai standard untuk uji praklinik pada 8 volunteer. Pada uji praklinik, menunjukkan koefisien korelasi area abdomen dan dada untuk Deep Inspiration Breath-Hold (DIBH) masing-masing sebesar 0,931±0,02 dan 0,936±0,03, dan untuk Free Breathing (FB) masing-masing adalah 0,85±0,08 dan 0,77±0,1. Data menunjukkan bahwa sistem gating berbasis laser in-house memiliki kinerja yang baik, dengan persentase kesalahan di bawah 10% dan koefisien korelasi yang baik menggambarkan bacaan yang diperoleh dari sistem laser konsisten dengan bacaan yang ditetapkan pada phantom dan sistem gating pernapasan klinis. Meskipun menjanjikan melalui proses kalibrasi dan uji praklinis, penelitian lebih lanjut diperlukan untuk menghasilkan data pemicu yang terhubung langsung dengan fasilitas CT dan linac, sehingga meningkatkan kelayakan klinis dari sistem gating berbasis laser yang inovatif ini. ......The respiratory gating system plays a role in addressing intrafraction motion in cancer treatment. Conventional non-invasive respiratory gating systems relying on a patient's body surface target surrogate may result in increased surface dose and diminished comfort. This early-stage design study introduces a laser-based gating system that eliminates patient contact while accurately detecting respiratory movements. Utilizing a Leuze laser, a custom in-house holder stands with a stepper motor and a Python-based program, the system converts respiratory data into a dataset for on-off beam triggers. The system performance is evaluated by calibration using Anzai AZ-773V phantom and CIRS motion phantom, also  preclinical testing is conducted on eight volunteers. Calibration with an Anzai AZ-773V phantom and a CIRS phantom demonstrated an average error of 0.94±0.75% and an average amplitude calibration correlation coefficient of 0.975±0.004. Preclinical tests, compared to the Anzai AZ-733V clinical system and real-time position management (RPM), revealed correlation coefficients for Deep Inspiration Breath-Hold (DIBH) is 0.931±0.02 and 0.936±0.03 respectively, and for Free Breathing (FB) is 0.85±0.08 and 0.77±0.1, respectively. The data suggests that the in-house laser-based gating system performs well, showing an error percentage below 10%. It has a reasonably good correlation coefficient, indicating that the readings obtained from the laser system are consistent with those set on the phantom and respiratory gating clinical. While promising through the calibration process and preclinical test, further studies are needed to generate trigger data linked directly for CT and linac facilities, advancing the clinical viability of this innovative laser-based gating system.
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2024
T-pdf
UI - Tesis Membership  Universitas Indonesia Library
cover
Dwi Aprilia Mahfirotin
Abstrak :
Pengukuran standar dosimetri referensi berkas elektron di seluruh dunia hingga kini mengacu pada protokol IAEA TRS-398 dan AAPM TG-51. Kedua protokol ini tidak merekomendasikan penggunaan detektor silinder untuk kalibrasi berkas elektron pada energi rendah. Namun, perkembangan standar dosimetri ini terus dikembangkan guna meningkatkan akurasi kalibrasi dosimetri berkas elektron dalam bidang radioterapi. Terdapat penelitian terbaru yang didasarkan pada AAPM TG-51 yaitu modifikasi kalibrasi berkas elektron. Pada metode tersebut digunakan detektor silinder pada energi rendah dan faktor konversi kualitas berkas terbaru menggunakan simulasi Monte Carlo. Pada studi ini dilakukan implementasi modifikasi kalibrasi berkas elektron dengan energi sebesar 6, 8, 10, 12, dan 15 MeV. Berkas elektron yang digunakan berasal dari dua jenis linear accelerator yaitu Elektra Synergy Platform dan Versa HD. Hasil bacaan muatan diukur dengan detektor PTW 30013, IBA CC13, Extradin A1Sl, dan Extradin A11 yang terhubung pada elektrometer. Dosis serap elektron disajikan dalam bentuk dosis per monitor unit pada kedalaman maksimum (Zmax). Pada studi ini modifikasi kalibrasi dibandingkan dengan TRS-398 untuk mengetahui akurasi hasil pengukuran kalibrasi dosis serap berkas elektron. Hasil pengukuran faktor konversi kualitas berkas antara TRS-398 dengan modifikasi kalibrasi menghasilkan perbedaan sebesar 11,12%. Perbandingan dosis serap antara modifikasi kalibrasi terhadap TRS-398 (Dw) untuk detektor silinder sebesar 1,002 cGy/MU pada Synergy Platform dan 1,000 cGy/MU pada Versa HD sedangkan untuk detektor plan-paralel sebesar 1,013 cGy/MU pada Synergy Platform dan 1,014 cGy/MU pada Versa HD. Metode modifikasi kalibrasi menghasilkan variabilitas hasil yang baik berdasarkan hasil standar deviasi dari pengukuran dosis rata-rata yang diperoleh dari berbagai detektor sebesar 0,5% pada Synergy Platform dan 0,8% pada Versa HD. Oleh karena itu, metode modifikasi kalibrasi dapat meningkatan akurasi hasil pada detektor silinder yang lebih baik dan lebih sederhana untuk diterapkan secara klinis ......The recently worldwide standard measurement of electron beam reference dosimetry refers to the protocols IAEA TRS-398 and AAPM TG-51. Neither of these protocols recommend the use of cylindrical chamber for electron beam calibration at low energies. However, the development of this dosimetry standard continues to improve the accuracy of electron beam dosimetry calibration in the radiation therapy. There is a recent study based on the AAPM TG-51, which is a modified calibration of electron beam. This method uses a low energy cylindrical chamber and the updated beam quality conversion factor using Monte Carlo simulation. In this study, the modified calibration was carried out with energies of 6, 8, 10, 12, and 15 MeV. The electron beam generated from two types of linear accelerator Elektra Synergy Platform and Versa HD. The results of charge readings were measured with PTW 30013, IBA CC13, Extradin A1Sl, and Extradin A11 connected to the electrometer. The absorbed dose to water for electron beam is expressed in dose per unit (cGy/MU) monitor at the maximum depth (Zmax). The result of beam quality conversion factor between TRS-398 with modified calibration showed a difference of 11,12%. The ratio of absorbed dose between modified calibration to TRS-398 (Dw) for cylindrical chamber resulted in an average of 1.002 cGy/MU on Synergy Platform and 1.000 cGy/MU on Versa HD while for plane-parallel chamber it was 1.013 cGy/MU on Synergy Platform and 1.014 cGy/MU on Versa HD. The modified calibration produces good variability in results based on the standard deviation of the average dose per monitor unit obtained from different chambers of 0.5% for Synergy Platform and 0.8% for Versa HD. Therefore, the modified calibration can improve the accuracy of the results on cylindrical chamber which is better and simpler to implement clinically.
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2021
T-pdf
UI - Tesis Membership  Universitas Indonesia Library