Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 33 dokumen yang sesuai dengan query
cover
Ginting, Mbantun
Abstrak :
Telah dibuat kapasitor lapisan tipis Ta205 dengan evaporasi berkas elektron Tantalum, yang dilanjutkan dengan elektrolisa oksidasi anodik secara arus konstan dalam elektrolit Amonium Borat ( 0,25 M, pH 8,2 ). Laju oksidasi pada rapat arus 0,33 mA cm-2 adalah sebesar 0,5 Ås-1. Dibuat beberapa sampel dengan leas berbeda ( 50, 100 dan 150 mm2 ), juga ketebalan yang bervariasi dart 229.67 --414,70 nm. Pengukuran kapasitansi dilakukan dengan tiga Cara yaitu 1.) RCL Bridge, 2.) Arus AC / Reaktansi Kapasitif dan 3.) Muatan tersimpan. Kapasitansi bervariasi antara 21,88 s/d 151,22 nF dan konstanta dielektrik 23,62 ( ± 5 % ). Faktor disipasi dapat bervariasi antara 0,01 s/d 0,39 dalam interval frekuensi 50 sampai 40.000 Ha. Kuat dielektrik salah satu sampel mencapai 0,6 MV cm-1. Kemasan kapasitor dalam resin ditemukan mengalami degradasi. Walaupun menunjukan sifat-sifat kapasitor yang baik, masih dapat disempurnakan pada eksperimen mendatang, terutama dalam usaha mengurangi porositas lapisan Tipis yang terbentuk.
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 1994
T-Pdf
UI - Tesis Membership  Universitas Indonesia Library
cover
Acep Musliman
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2004
T39808
UI - Tesis Membership  Universitas Indonesia Library
cover
Galih Prabowo
Abstrak :
Telah dibuat kVp meter Sinar-X radiodiagnostik dalam penelitian yang terdiri dari rangkaian sensor Photodiode Transimpedance OPT 101, rangkaian Operational Amplifier, rangkaian Analog to Digital Converter (ADC) dan mikrokontroller ATMEL 89S52. Pengukuran tegangan tabung pesawat sinar-X dengan kVp meter berdasarkan konsep perbedaan atenuasi berkas radiasi oleh dua absorber berbeda dan dideteksi oleh sepasang Photodiode yang identik. Rasio dari sinyal output photodioda merupakan fungsi kVp yang kemudian dikalibrasi dengan kVp meter yang telah terkalibrasi RMI. Penyinaran dilakukan pada rentang tegangan 60 kVp sampai dengan 90 kVp dan dengan filter 1 mm, 2 mm, 3 mm, dan 4 mm. Hasil dari penelitian ini adalah hubungan linear antara bacaan kVp meter dengan bacaan panel pesawat namun masih belum konsisten dan membutuhkan penelitian lebih lanjut. Pasangan filter 1 dan 4 mm memperlihatkan hasil yang paling baik dan konsisten.
Voltage peak measurement device has been made that consists circuit of photodiodes transimpedance sensor OPT 101, Operational Amplifier, Analog to Digital Converter (ADC), and ATMEL 89S52 microntroller. Kilovoltage peak is maximum voltage that is applied across an X-ray tube that yields maximum X-ray energy. The measurement makes use of different attenuation of X-ray beam by two different absorbers and were detected by two identical photodiodes. The ratio of the signals from the two diodes is a function of peak kilovoltage. Results were calibrated by comparing with a calibrated commercial kVp meter. Series of exposures are made using peak voltage ranging from 60 kVp to 90 kVp for four different thicknesses of Alumunium pair filter. The result show a linear relationship between output kVp metre and panel X-ray machine but otherwise were not sufficiently stable and consistent. Pair of 1 and 4 mm Al filter was found to produce best and consistent results.
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2006
S28886
UI - Skripsi Membership  Universitas Indonesia Library
cover
Gunawan Hiroshi
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 1994
S28174
UI - Skripsi Membership  Universitas Indonesia Library
cover
Sinaga, Oskar
Depok: Universitas Indonesia, 1995
S28330
UI - Skripsi Membership  Universitas Indonesia Library
cover
Dedy Yumanta
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 1995
S28369
UI - Skripsi Membership  Universitas Indonesia Library
cover
Widy Harsanto
Abstrak :
Telah dilakukan studi penggunaan photostimulable phospor (PSP) dari unit Computed Radiography Fuji FCR XG-1 untuk menentukan distribusi dosis pada pesawat radiografi konvensional. Penyinaran dilakukan dengan menyisipkan PSP di antara fantom akrilik dengan ketebalan bervariasi 1-26 cm baik untuk penyinaran vertikal (inplane dan crossplane) maupun horizontal dengan variasi tegangan tabung (kVp) dan luas lapangan. Kalibrasi pixel intensity terhadap dosis dilakukan dengan meletakkan detektor TLD di bawah setiap step dari stepwedge aluminium pada 100 kV. Hubungan pixel intensity dan dosis ditemukan tidak linier namun lebih ke cubic spline. File citra diperoleh dalam bentuk baku DICOM yang kemudian diolah menggunakan Software MATLAB. Hasil olahan dapat memperlihatkan distribusi dosis maupun profil berkas dan dipermudah juga dengan pemetaan kontour untuk memperoleh garis isopixel/ isodosis. Hasil analisa dari berbagai citra ini mampu memberikan gambaran mengenai distribusi dosis dari sinar-X pada jaringan termasuk kontribusi berkas primer maupun sekunder dan membuktikan flexibilitas computed radiography dibandingkan dengan radiologi film konvensional.
A study on the use of photostimulable phosphor (PSP) from a Fuji FCR XG-1 Computed Radiography System (CR) to determine dose distribution from a conventional radiography unit has been investigated. Exposures were taken on slabs of acrylic phantom where PSP was inserted at certain thickness (1-26 cm) both vertically and horizontally at varying tube voltage (kVp) and field sizes. Pixel intensity was calibrated to dose by placing TLDs below each steps of a standard Al stepwedge at 100 kVp and was found to fit a cubic spline curves. Image files were taken in DICOM standard but was read and directly analyzed using MATLAB applications including CONTOUR determination that helps to show isodose / isopixel lines clearly. The results of image analysis were found to sufficiently describe dose distribution, beam profiles and other X-ray beam parameters. This also showed the flexibility of CR as a mean of imaging system as compared to conventional film radiography.
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2006
S29262
UI - Skripsi Membership  Universitas Indonesia Library
cover
Gomgom
Abstrak :
Telah dilakukan studi respon imaging plate tipe C BW Fuji Computed Radiography terhadap berkas sinar gamma Cobalt 60 dengan penyinaran horizontal dan vertikal dan didapatkan image digital dalam format DICOM yang diolah dengan bantuan software MATLAB. Hasil respon IP mengalami saturasi pada kedalaman 1- 4 cm pada penyinaran horizontal dan penurunan nilai pixel intensity terjadi pada kedalaman 5 - 10 cm. Saturasi disebabkan oleh oversensitivitas sinar gamma Co-60 walaupun dengan waktu penyinaran terpendek (0.03 menit.). Kalibrasi dengan bilik tidak terlalu baik pada dosis yang sangat rendah dan menghasilkan data kalibrasi yang tidak konklusif. Penyinaran vertikal secara kualitatif memperlihatkan respons IP terhadap kedalaman namun tidak digunakan dalam perhitungan dosis karena oversensitivitas IP pada energi rendah dominan pada daerah ini. Penggunaan IP tipe C BW Fuji Computed Radiography tidak cocok untuk merespon energi sinar Cobalt 60. Pada kedalaman yang cukup hasil penyinaran horizontal dapat memperlihatkan distribusi dosis dua dimensi pada bidang target. Penggunaan perintah CONTOUR pada MATLAB juga sangat memudahkan visualisasi distribusi dosis lengkap dengan garis-garis isodosis / isopixel.
A study on imaging plate tipe C BW Fuji Computed Radiography to determine its response to Co-60 gamma ray irradiation both vertically and horizontally has been done using acrylic slabs phantom with varying thicknesses or depths. Image was egistered in DICOM standard file and then read and analyzed using MATLAB. IP reponse showed saturation at low depths (1-4 cm) on horizontal irradiation and showed normal decrease at higher depths. Saturation was caused by oversensitivity of IP to Cobalt gamma ray even using the shortest irradiation time (0.03 minute.). Calibration using ionization chamber was found to be highly inaccurate at this low dose level and should not be used in this manner. Vertical irradiation showed IP response to gamma ray at depths qualitatively but should not be used quantitatively due to high oversensitivity at depths. IP type C BW Fuji Computed Radiography is not suitable for radiotherapy uses and should be avoided in the future. In sufficient depths horizontal irradiation can show clear dose distribution in 2D on target irradiation fields. The use of Contouring in MATLAB is also useful in showing isodose / isopixel lines.
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2006
S29229
UI - Skripsi Membership  Universitas Indonesia Library
cover
Rr. Winda Kusuma Ningrum
Abstrak :
Telah dilakukan studi perbandingan kurva karakteristik film konvensional dan film laser pada CR pada kVp dan mAs dan tegangan kVp yang dibutuhkan pada penyinaran fantom berbagai ketebalan (0-15 cm) untuk mencapai Eksposure Indeks CR sebesar 1800-2000. Dari hasil percobaan diketahui bahwa imaging plate lebih sensitive dibanding film konvensional namun detail dan kontras gambar lebih rendah. Pada percobaan kVp versus ketebalan fantom diperoleh hubungan tidak linier (cubic spline) dan ini semua diperoleh pada kVp lebih tinggi dari film konvensional untuk ketebalan fantom yang sama dan semua penyinaran menghasilkan Eksposure indeks rata-rata 1838 ± 39.
A study has been performed to compare characteristic curve of conventional film and laser film of a CR unit at the same kVp and mAs. The results showed that laser film is more sensitive than conventional film but should be carefully used since the study lacks contrast and detail measurements. Measurements of kVp needed to expose varying thicknesses of phantoms to obtain CR exposure index of 1800-2000 showed non linear relationship between kVp and thickness with. Overall CR index for last measurements was 1838 ± 39.
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2006
S29227
UI - Skripsi Membership  Universitas Indonesia Library
cover
Dian Milvita
Depok: Fakultas Matematika dan Ilmu Pengetahuan Alam Universitas Indonesia, 2004
S39708
UI - Tesis Membership  Universitas Indonesia Library
<<   1 2 3 4   >>