Hasil Pencarian  ::  Simpan CSV :: Kembali

Hasil Pencarian

Ditemukan 190790 dokumen yang sesuai dengan query
cover
Dika Aning Diyani
"ABSTRAK
Air merupakan salah satu unsur penting tubuh dan salah satu zat gizi makro selain
karbohidrat, lemak, dan protein. Namun, air sering dilupakan sehingga tanpa disadari banyak
remaja yang mengalami dehidrasi ringan. Tujuan penelitian ini adalah untuk mengetahui
hubungan aktivitas fisik, pengetahuan dan faktor lainnya dengan konsumsi air putih pada
mahasiswa FKM UI. Desain penelitian ini adalah cross sectional. Penelitian dilaksanakan
pada bulan April 2012 di FKM UI dengan total sampel 123 orang yang diambil dengan
simpel random sampling. Variabel independen yang diambil adalah karakteristik responden
(jenis kelamin, uang saku, pendidikan orangtua, pekerjaan orangtua, dan luas permukaan
tubuh), pengetahuan, kebiasaan, cara mendapatkan air minum, dan aktivitas fisik. Konsumsi
air minum diperoleh dengan pengisian FFQ semi kuantitatif sementara variabel lainnya
diperoleh dengan pengisian kuesioner. Untuk luas permukaan tubuh diperoleh dari perkalian
dengan rumus Du Bois antara berat badan yang diambil dengan timbangan seca dan tinggi
badan yang diambil dengan microtoise. Analisis bivariat dilakukan dengan uji chi square.
Terdapat 49,6% responden yang konsumsi air minumnya masih kurang dengan rata-rata
minum 2.233 ml/hari. Hasil uji statistik menunjukkan bahwa konsumsi air minum
mempunyai hubungan signifikan dengan aktivitas fisik, kebiasaan minum dan pengetahuan.
Mahasiswa diharapkan dapat meningkatkan pengetahuan dan kebiasaan minum yang baik
sehingga dapat menyadari pentingnya air bagi tubuh.

ABSTRACT
Water is one important element of the body and one of the macro nutrients
other than carbohydrates, fats, and proteins. However, water is often forgotten that
many teens who unwittingly mild dehydration. The purpose of this study was to
determine the relationship of physical activity, knowledge and other factors with
the consumption of water in FKM UI students. The study design was cross
sectional. The experiment was conducted in April 2012 in FKM UI with total
sample 123 people are taken by simple random sampling. Independent variables
taken are the characteristics of the respondents (gender, allowances, parental
education, parental employment, and body surface area), knowledge, habits, how
to get drinking water, and physical activity. Consumption of drinking water is
obtained by semi-quantitative FFQ while the other variables obtained by filling a
questionnaire. Body surface area obtained from the multiplication formula of Du
Bois weight taken with Seca scales and height are taken with microtoise. Bivariat
analysis is carried out by chi square test. There were 49.6% of respondents still
lack drinking water consumption by an average drink 2233 ml / day. The results
of statistical tests indicate that the consumption of drinking water has a significant
relationship with physical activity, drinking habits and knowledge. Students are
expected to increase the knowledge of good and drinking habits so as to realize
the importance of water for the body.
"
Depok: Fakultas Kesehatan Masyarakat Universitas Indonesia, 2012
S-Pdf
UI - Skripsi Open  Universitas Indonesia Library
cover
Armaji Kamaludi Syarif
"ABSTRAK
Laporan UNICEF pada tahun 2014 menyatakan bahwa Indonesia adalah negara terbesar kedua di
dunia dengan praktik buang air besar sembarangan. Puskesmas adalah garis depan dalam
menangani masalah ini, salah satu programnya adalah memastikan cakupan sanitasi air bersih dan
jamban sehat di wilayahnya. Penelitian ini bertujuan untuk memperoleh informasi terkait
pengaruh kepemimpinan dan kegiatan operasional terhadap kinerja UKM terkait cakupan sanitasi
air bersih dan jamban sehat dengan menggunakan kriteria Baldrige Excellence Framework. Data
yang relevan dari penelitian indeks kualitas pelayanan kesehatan masyarakat yang dilakukan oleh
Badan Litbangkes dianalisis lanjut secara deskriptif dan analitik dengan menggunakan Structural
Equation Modeling (SEM). Kepemimpinan berhubungan signifikan dengan kegiatan operasional
dengan standardized coefficient 0,99 (p-value 0,05); kegiatan operasional berhubungan tidak
signifikan dengan kinerja dengan standardized coefficient 0,09 (p-value 0,05); kepemimpinan
berhubungan tidak langsung secara tidak signifikan dengan kinerja melalui kegiatan operasional
dengan standardized coefficient 0,09 (p-value 0,05). Berbagai faktor dapat menyebabkan hal
tersebut namun ketidakcocokan kovarian dari variabel di populasi dan sampel serta kemungkinan
peran sektor lain yang lebih besar menjadi dua hal yang menonjol. Kesimpulannya, kinerja UKM
puskesmas terkait cakupan sanitasi air bersih dan jamban sehat masih kurang baik, sehingga perlu
adanya peningkatan capaian indikator-indikator kepemimpinan dan kegiatan operasional yang
harus bekerjasama erat dengan sektor lain.

ABSTRACT
The 2014 UNICEF report stated that Indonesia is the second largest country in the world in
practicing open defecation. The puskesmas is the front line in dealing with this problem, one of
the programs is to ensure the coverage of clean water sanitation and healthy toilets in the area.
This study aims to obtain information regarding the influence of leadership and operational
activities on the performance of public health effort related to the coverage of clean water and
healthy toilet by using the Baldrige Excellence Framework criteria. Relevant data from the
research on the quality index of public health services carried out by the National Institute of
Health and Research Development were further analyzed descriptively and analytically using
Structural Equation Modeling (SEM). Leadership was significantly related to operational
activities with a standardized coefficient of 0.99 (p-value 0.05); operational activities were not
significantly related with performance with a standardized 0.09 coefficient (p-value 0.05);
leadership was not indirectly related significantly to performance through operational activities
with a standardized coefficient of 0.09 (p-value 0.05). Various factors can cause this situation
but covariance mismatches of variables in the population and the sample; and the possibility of
the role of other sectors are the two most probable explanations. In conclusion, the performance
of UKM health centres related to the coverage of clean water and healthy latrines is still not good,
so there are needs to increase in the achievement of leadership indicators and operational activities
which are followed by working closely with other sectors.
"
2019
T53871
UI - Tesis Membership  Universitas Indonesia Library
cover
Verena Amanda
"

Air minum yang aman menjadi salah satu kebutuhan yang krusial bagi manusia. Air tanah merupakan salah satu sumber utama untuk memperoleh air minum. Kualitas air dapat bervariasi berdasarkan sumber kontaminan dan waktu atau musim pada tahun tersebut, sehingga diperlukan langkah tambahan untuk memastikan kualitas air. Data penelitian diperoleh dari data historis parameter kimia pH dan konduktivitas untuk sumber air pada salah satu perusahaan Fast Moving Consumer Goods (FMCG) di Indonesia dari bulan Januari 2021 hingga Februari 2023. Data dibagi menjadi dua bagian, training set dan testing set yang kemudian digunakan untuk memprediksi kualitas sumber air menggunakan pendekatan Recurrent Neural Network (RNN) dengan arsitektur Long Short-Term Memory (LSTM) dan Gated Recurrent Units (GRU). Dari penelitian ini, didapatkan pendekatan terbaik yang dapat digunakan untuk mendapatkan akurasi tertinggi pada setiap model yang dibangun. Secara keseluruhan, pendekatan RNN dengan arsitektur LSTM dan GRU dapat digunakan untuk memprediksi kualitas sumber air dengan akurasi yang tinggi.


Safe drinking water is a crucial need for humans. Groundwater is one of the main sources to get drinking water. Water quality varies based on contaminants and time or season of the year, therefore extra steps to ensure water quality are needed. This research used pH and conductivity chemical parameters historical data for source water at one of Fast Moving Consumer Goods (FMCG) companies in Indonesia from January 2021 until March 2023. Data is divided into two sections, the training set and testing set which were used to predict source water quality using Recurrent Neural Network (RNN) with Long Short-Term Memory (LSTM) and Gated Recurrent Units (GRU) architectures. This research aims to know the best approach to use to get the highest accuracy for each developed model. Overall, the RNN approach with LSTM and GRU architectures can be used to predict source water quality with high accuracy.

"
Depok: Fakultas Teknik Universitas Indonesia, 2023
S-pdf
UI - Skripsi Membership  Universitas Indonesia Library
cover
Cheremisinoff, Paul N.
Englewood Cliffs, N.J.: Prentice-Hall, 1993
628.1 CHE w
Buku Teks  Universitas Indonesia Library
cover
Rohmania Prihatini
"Banyak masyarakat yang menggunakan Air Minum Isi Ulang (AMIU), meskipun kualitas AMIU masih diragukan terutama bila dilihat dari segi kontaminasi biologi. Tujuan dari penelitian ini adalah untuk mengukur bagaimana kualitas AMIU pada Depot Air Minum (DAM) di Kabupaten Bogor Tahun 2008- 2011. Penelitian menggunakan studi analitik deskriptif dengan desain cross sectional. Jumlah sampel yang diambil adalah DAM yang telah terdaftar di Dinas Kesehatan Kabupaten Bogor dan telah memiliki sertifikat Laik Higiene Sanitasi DAM serta hasil uji laboratorium untuk bakteri Escherichia coli yang berjumlah 88 depot.
Hasil penelitian menunjukkan aspek penilaian sumber air baku sangat baik karena 79 (90%) DAM memiliki skor ≥70, aspek penilaian tandon air baku baik karena 76 (86%) DAM memiliki skor ≥70 , aspek penilaian sanitasi depot kurang karena 33 (38%) DAM memiliki skor ≥210, aspek penilaian higiene perorangan kurang karena 41 (47%) DAM memiliki skor ≥70, aspek penilaian alat produksi sangat baik karena 80 (91%) DAM memiliki skor ≥70, aspek penilaian proses pengemasan kurang karena 40 (45%) DAM memiliki skor ≥70, serta aspek penilaian manajemen dan pengendalian mutu kurang karena hanya 11 (13%) DAM memiliki skor ≥140. Hasil uji bivariat menunjukkan tidak ada perbedaan nilai skor pada ketujuh aspek penilaian kecuali pada aspek penilaian manajemen dan pengendalian mutu menunjukkan ada perbedaan nilai antara DAM yang memenuhi syarat dan tidak memenuhi syarat (P value 0,001) terhadap kualitas air minum isi ulang.
Kesimpulan dari penelitian ini adalah dari 88 DAM yang diteliti, hanya 3 depot (3%) yang kualitas produk air minumnya tidak memenuhi persyaratan uji mikrobiologis sesuai dalam Kepmenkes RI No 492/MENKES/PER/IV/2010, sehingga kualitas air minum isi ulang di wilayah Kabupaten Bogor dapat dikatakan masih berada dalam kualitas yang baik.

So many people who use drinking water from water refill station, although the quality is still questionable especially when viewed in terms of biological contamination. The purpose of this study was to measure how the refill drinking water quality in water refill station in Bogor regency in time period from 2008- 2011. The study using descriptive analytical study with cross sectional design. Number of samples taken are all water refill station which has been registered in Health Department Bogor regency and have sanitation higiene certificate and laboratory test results of the bacterium Escherichia coli which is reached 88 water refill station.
The results of seven aspects assesment show that raw water source was very good because 79 (90%) water refill station has score ≥70, raw water reservoir was good because 76 (86%) water refill station has score ≥70, water refill station sanitation was less because 33 (38%) water refill station has score ≥210, personal hygiene was lack because 41 (47%) water refill station has a score ≥70, tools of production was very good because 80 (91%) water refill station has a score ≥70, packaging process was less because 40 (45%) water refill station has a score ≥70 and quality control assessment was less because 11 (13%) water refill station has a score ≥140. Bivariate test results showed no differences on seven aspects score of assessment except management and quality control assessment aspects between water refill station value which eligible and ineligible (P value 0.001) with the quality of refill drinking water.
The conclusion in this study from 88 water refill station studied only 3 water refill station (3%) does not appropriate with drinking water microbiological testing requirements according to the Decree Health Department Decision 492/MENKES/PER/IV/2010, so the quality of refill drinking water in Bogor regency can be said is still in good quality.
"
Depok: Fakultas Kesehatan Masyarakat Universitas Indonesia, 2012
S-Pdf
UI - Skripsi Open  Universitas Indonesia Library
cover
Lina Damayanti
"Tesis ini menganalisis faktor-faktor yang mempengaruhi keberlanjutan sistem penyediaan air minum yang dikelola oleh masyarakat di pedesaan. Penelitian ini dilakukan di dua desa yaitu desa Sindanggalih dan desa Bayongbong, Kabupaten Garut. Metode penelitian yang digunakan adalah metoda kualitatif dengan desain deskriptif. Hasil penelitian menyimpulkan bahwa faktor-faktor yang mempengaruhi keberlanjutan sistem penyediaan air minum yang dikelola oleh masyarakat di pedesaan adalah teknik, keuangan, kelembagaan, sosial dan lingkungan, serta dukungan pihak luar terutama Pemerintah Daerah. Hal tersebut sejalan dengan amanat Undang-Undang No. 23 tahun 2014 tentang Pemerintahan Daerah, pelayanan dasar termasuk di dalamnya pelayanan air minum merupakan urusan pemerintah konkuren yang menjadi kewenangan pemerintah daerah yang bersifat wajib.
Hasil penelitian menyarankan agar Pemerintah Daerah membangun sistem dukungan yang lebih sistematik dan terstruktur agar tidak lagi bersifat ad hoc dan bisa menyentuh seluruh desa yang mempunyai pengelolaan dengan tipe serupa. Skema dukungan tersebut disarankan melibatkan pihak lain, baik itu lembaga pemerintah maupun non-pemerintah, misalnya balai pelatihan, PDAM, BLHD, swasta yang mempunyai program CSR, dan perbankan untuk akses pembiayaan komersil.

This thesis analyzes the factors that influence the sustainability of the community managed rural water supply system. The research was conducted in two villages, which are Sindanggalih and Bayongbong in district of Garut. The method used is qualitative method with descriptive design. The study concluded that the factors affecting the sustainability of community managed rural water supply are technical, financial, institutional, social and environmental, as well as external support, especially from Local Government. This is in line with the mandate of the Act No. 23 of 2014 on Regional Government, basic services including water services is a concurrent government affairs under the mandatory authority of local government.
The results of the study suggest that local governments should build a more systematic and structured supporting system so as no longer to be ad hoc and could provide continuous support to all villages that have similar management model. It is also suggested that the supporting scheme involving other parties, both government and non-government, for example, training institution, water utility, local environmental agency, private with CSR program, and bank to access commercial financing.
"
Depok: Fakultas Ilmu Sosial dan Ilmu Politik Universitas Indonesia, 2016
T45651
UI - Tesis Membership  Universitas Indonesia Library
cover
Bobby Demeianto
"ABSTRAK
Pada suatu Instalasi Pengolahan Air ( IPA ) terdapat proses pengolahan dan pendistribusian air, untuk mendistribusikan kebutuhan air dibutuhkan peralatan bantu yang mampu menyuplai air bersih sesuai dengan yang dibutuhkan. Dalam aplikasi penyuplaian air pada instalasi pengolahan air (IPA), kebutuhan air bersih khususnya di daerah ibu kota DKI Jakarta semakin lama semakin meningkat membuat kinerja pompa semakin besar dalam pendistribusiannya sehingga sering mengabaikan besarnya energi yang di pakai dalam menghasilkan dan mendistribusikan air bersih.
Jumlah energi listrik yang diperlukan untuk proses pemompaan sendiri sangatlah besar mengingat pola pengaturan pendistribusian air yang menggunakan metode buka-tutup valve pada outlet pompa yang mengakibatkan adanya pemakaian energi yang tidak efisien dan terbuang percuma. Sebagai informasi bahwa di IPA Pejompongan I persentase daya yang dipakai oleh pompa distribusi adalah sekitar 74% dari jumlah total pemakaian energi listrik. Untuk itu perlu dilakukan modifikasi terhadap pengaturan pemakaian energi listrik yang dikonsumsi oleh motor pompa menggunakan alat pengaturan kecepatan motor atau yang disebut dengan Variabel Speed Drive ( VSD ) agar energi yang dikonsumsi sesuai dengan energi dikeluarkan untuk proses pemompaan tanpa adanya pengaturan bukaan katup keluaran pompa.
Dari hasil pengukuran dan pengujian serta perhitungan yang dilakukan dengan menggunakan pendekatan regresi polynomial didapatkan bahwa penggunaan MV-VSD pada stasiun pompa Jakarta IPA 1 dapat menurunkan pemakaian energy listrik dari yang sebelumnya rata-rata konsumsi energy listrik pada stasiun pompa tersebut dapat mencapai 16,704.88 kWh/hari dapat diturunkan hingga mencapai 7,269.61 kWh/hari. Tentunya dengan adanya saving energy sebesar 56 % tersebut secara langsung dapat menurunkan biaya operasional berupa biaya tagihan listrik setiap bulannya.

ABSTRACT
At a Water Treatment Plant in IPA there are the processing and distribution of water , to distribute water needs capable equipment for supplying clean water as required . In the application of water supplies at the water treatment plant ( WTP ) in IPA , the need for clean water , especially in the capital city of Jakarta progressively increasing pump performance makes greater in distribution so often overlook the amount of energy that is in use in generating and distributing clean water .
The amount of electrical energy required for pumping process itself is enormous considering the pattern of water distribution arrangement using the method of opening and closing the valve at the pump outlet which resulted in the inefficient use of energy and wasted.For information on IPA I potty percentage of power used by the pump distribution is approximately 74 % of the total electrical energy consumption . It is necessary modifications to the regulation of energy consumption of electricity consumed by the pump motor using a motor speed setting or the so-called Variable Speed Drive ( VSD ) so that the energy consumed in accordance with the energy released in the process of pumping without a pump outlet valve aperture settings .
From the results of measurements and testing as well as calculations performed using polynomial regression approach showed that the use of MV - VSD in Jakarta?s pump station at IPA 1, MV-VSD can reduce electrical energy consumption of the previous average consumption of electrical energy at the pump station can be reached 16,704.88 kWh / day can be lowered up to 7,269.61 kWh / day . Obviously with the energy saving of 56% can reduce the direct operating costs such as the cost of electricity bills every month"
Jakarta: Fakultas Teknik Universitas Indonesia, 2014
T42105
UI - Tesis Membership  Universitas Indonesia Library
cover
Gian Ratulangi Bhumindra
"Limbah padat lumpur IPA Pejompongan I dan II dari proses koagulasi-flokulasi-sedimentasi sampai saat ini dibuang ke sungai Krukut dan memiliki potensi untuk mencemarkan sungai tersebut. Studi pemanfaatan kembali lumpur IPA Pejompongan I dan II sebagai koagulan dilakukan untuk mengurangi residu yang dibuang ke sungai. Dalam penelitian penggunaan kembali lumpur sebagai koagulan yang dilakukan adalah menentukan kondisi terbaik yang dibutuhkan agar lumpur dapat digunakan sebagai koagulan. Metode jartest digunakan untuk mengaetahui kondisi optimum dan efisiensi pemakaian kembali lumpur. Kandungan aluminium merupakan senyawa yang sangat vital dan pemulihan aluminium dilakukan dengan pengeringan dan kalsinasi sampel lumpur terlebih dahulu.
Kondisi optimum untuk sampel lumpur IPA Pejompongan I dan II dengan dosis sebesar 9,01 dan 7,5 mg dengan kecepatan pengadukan cepat 140 dan 100 rpm selama 1 menit, lalu kecepatan pengadukan lambat sebesar 20 rpm selama 15 menit dan sedimentasi selama 60 menit. Efektivitas pemakaian lumpur sebagai koagulan untuk sampel I adalah sebesar 97,73 % dan sampel II sebesar 98,19 %. Hasil pemakaian dapat mencapai baku mutu kekeruhan yang telah ditetapkan pada Permenkes No. 492/menkes/per/iv/2010 Tentang Persyaratan Kualitas Air Minum yaitu 5 NTU sedangkan kekeruhan yang diperoleh adalah sebesar 4 NTU untuk kedua sampel. Hal ini membuktikan bahwa pemakaian kembali lumpur IPA Pejompongan I dan II sebagai koagulan dapat dilakukan.

Sludge residu from coagulaton-flocculation-sedimentation process of Pejompongan I and II water treatment plant, have been disposed at Krukut river until the present day and the residue may be a threat of pollution to the river. Studies of reusing the sludge residu of Pejompongan I and II water treatment plant as a coagulant may decrease the amount of residu which are disposed at the river. In the study of reusing sludge as a coagulant, the search of the optimum conditions of the sludge is needed to be done by using jar test methode. Aluminium recovery is the vital core of this study, where to recover the remaining aluminium in the sludge residu, dewatering and calcination treatment has to be implemented to the sample.
The optimum condition for the sludge sample from Pejompongan I and II is 9,01 and 7,5 mg dosage of the sample with a fast mixing rate of 140 and 100 rpm for 1 minute and slow mixing rate of 20 rpm for 15 minutes then 60 minutes of sedimentation for settling. Effectivity of sludge reuse as a coagulant for sample I (Pejompongan I) is 97,73 % and sample II (Pejompongan II) IS 97,73 %. The result of the usage of the sample has reached the standard of turbidity which is stated by Permenkes No. 492/menkes/per/iv/2010 Tentang Persyaratan Kualitas Air Minum with the standard of 5 NTU, where as turbidity obtained is equal to 4 NTU for both samples. The reuse of sludge residu from Pejompongan I and II water treatment plant as a coagulant has been proven successful.
"
Depok: Fakultas Teknik Universitas Indonesia, 2016
S65026
UI - Skripsi Membership  Universitas Indonesia Library
cover
Astri Syativa
"ABSTRAK
Dua puluh tahun terakhir ini kondisi lingkungan dan kualitas air di
sepanjang Sungai Citarum semakin menurun. Akses penduduk di sekitar Citarum
terhadap air bersih dan sarana sanitasi dasar pun masih rendah, dengan angka
kesakitan diare yang tinggi. Integrated Citarum Water Resources Management
Investment Program (ICWRMIP) merupakan upaya yang dilakukan oleh
pemerintah untuk mengatasi berbagai permasalahan yang ada di DAS Sungai
Citarum dan Saluran Tarum Barat. Kementerian Kesehatan berperan dalam
ICWRMIP Sub Komponen 2.3 yang bertujuan untuk meningkatkan penyediaan
air bersih, sanitasi, dan meningkatkan derajat kesehatan masyarakat. Penelitian ini
bertujuan untuk menganalisis pengaruh ICWRMIP Sub Komponen 2.3 terhadap
akses air bersih, akses jamban sehat dan kejadian diare serta menganalisis
pengaruh akses air bersih dan jamban sehat terhadap kejadian diare. Penelitian ini
menggunakan rancangan studi cross-sectional berulang. Data dikumpulkan
sebelum dan sesudah program, di lokasi program dan non program, dengan besar
sampel 300 responden pada tiap kelompok. Hasil penelitian menunjukkan bahwa
kegiatan ICWRMIP Sub Komponen 2.3 berpengaruh meningkatkan akses air
bersih dan akses jamban sehat serta menurunkan kejadian diare. Semua variabel
berhubungan dengan kejadian diare: akses air bersih (OR=1,74; 1,33-2,28), akses
jamban sehat (OR=2,48; 1,88-3,28), program (OR=7,17; 4,68-10,99), dan waktu
(OR=5,10; 3,33-7,80). Disimpulkan bahwa rumah tangga di lokasi non program
tanpa akses jamban sehat pada saat sebelum ada program berisiko 7,75 kali lebih
besar mengalami kejadian diare dibandingkan dengan rumah tangga di lokasi
program yang akses jamban sehat setelah program.

ABSTRACT
The condition of the environment and water quality along the Citarum River
has declined in the last twenty years. Access people around Citarum to clean
water and basic sanitation facilities is low, with high diarrhea morbidity. Integrated
Citarum Water Resources Management Investment Program (ICWRMIP) is an effort by
the government to solve the problems that exist in Citarum and West Tarum
Canal. Ministry of Health is involve on Sub Component 2.3, that aims to improve
water supply, sanitation, and improving public health. This study aims to analyze
the effects of ICWRMIP Sub Component 2.3 to clean water access, healthy latrine
access and diarrhea, and also to analyze the effect of access to clean water and
healthy latrines on the incidence of diarrhea. This study uses repeated crosssectional
study design. Data were collected before and after the program, on-site
program and non-program, with sample size 300 respondents in each group. The
results showed that ICWRMIP Sub Component 2.3 affects to improve clean water
and healthy latrines access, and also reduce the incidence of diarrhea. All
variables associated with the incidence of diarrhea: clean water access (OR=1,74;
1,33-2,28), healthy latrines access (OR=2,48; 1,88-3,28), program (OR=7,17;
4,68-10,99), and time (OR=5,10; 3,33-7,80). Concluded that households in nonprogram
locations without access to healthy latrines at the time before program
7.75 times greater risk of experiencing diarrhea compared with on-site household
latrine access program healthy after the program."
Universitas Indonesia, 2013
T-Pdf
UI - Tesis Membership  Universitas Indonesia Library
cover
Eki Noerfitriyani
"Pengoperasian TPA dapat menimbulkan permasalahan lingkungan akibat dekomposisi sampah berupa produksi lindi.TPA Cipayung memiliki instalasi pengolahan lindi menggunakan kolam stabilisasi denganSungai Pesanggrahan sebagai badan air penerima. Pemeriksaan kualitas lindi dan air sungai diperlukan untuk memastikan pembuangan lindi ke badan air telah memenuhi baku mutu.Karakteristik lindi bersifat fluktuatif dengan temperatur antara 33,8oC ndash; 36,4oC, konsentrasi TSS sebesar 70mg/L- 75mg/L, nilai pH 7,8 ndash; 7,9, BOD 2.874,0mg/L - 4.826mg/L, COD 4.586,4mg/L- 8.937,6mg/L, Total Nitrogen280mg/L- 466,7mg/L, dan logam berat Merkuri0,0008mg/L- 0,0032mg/L, sertaKadmiumdi bawah 0,001mg/L. Efluen Instalasi Pengolahan Lindi belum memenuhi baku mutu lindi sehingga perlu dilakukan evaluasi terhadap unit pengolahan. Hasil evaluasi desain unit Instalasi Pengolahan Lindi TPA Cipayung menunjukan bahwa desain kolam anaerobik, kolam fakultatif, dan kolam maturasi tidak memenuhi kriteria desain sehingga diperlukan desain perbaikan. Efluen lindi IPL TPA Cipayung mempengaruhi kualitas Sungai Pesanggrahan berdasarkan kenaikan konsentrasi parameter BOD, COD, dan Total Nitrogen, serta penurunan konsentrasi DO. Analisis statistik Korelasi Pearson menunjukan keterkaitan antara parameter kualitas lindi COD dan TN r=-0,997, p.

Operation of landfill caused environmental problems by waste decomposition in the form of leachate production. CipayungLandfill has leachate treatment plantusing stabilization pond with Pesanggrahan River as recipient water body. Examination of leachate and water quality of Pesanggrahan River is needed to ensure that leachate discharge to water bodies does not excessed the standard limit. The characteristics of leachate are fluctuated with temperatureranged from 33,8oC ndash 36,4oC, concentration of TSS 70mg L 75mg L, pH 7,8 to 7,9, BOD 2.874mg L 4.826mg L,COD 4.586,4mg L 8.937,6mg L, Total Nitrogen 280mg L 466,7mg L, and heavy metals Mercury 0,0008mg L 0,0032mg L, while Cadmium below 0,001mg L. Effluent of leachate excessedthe leachate standard limit, and need to be evaluated. The result of design evaluation shows that the anaerobic pond, facultative pond, and maturation ponddesign do not meet design criteria, and design improvement is needed. Leachate effluent of Cipayung Landfill affect the quality of Pesanggrahan River based on the increased of BOD, COD, and Total Nitrogen concentration, and decreased of DO. Statistical analysis Pearson Correlation showed correlation between leachate quality parameter COD and TN r 0,997, p"
Depok: Fakultas Teknik Universitas Indonesia, 2017
S67317
UI - Skripsi Membership  Universitas Indonesia Library
<<   1 2 3 4 5 6 7 8 9 10   >>